2013 Fiscal Year Final Research Report
320-detector-row computed tomography arteriography using CO2 gas to detect malignant liver tumors
Project/Area Number |
23591817
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | Shiga University of Medical Science |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
OHTA Shinichi 滋賀医科大学, 医学部, 講師 (30583637)
NITTA Norihisa 滋賀医科大学, 医学部, 講師 (40324587)
|
Project Period (FY) |
2011 – 2013
|
Keywords | CO2 / マルチディテクター / MDCT / ガス / 血管造影 / TACE |
Research Abstract |
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas to detect the vascular area of malignant liver tumors. We studied six patients with primary and metastatic liver tumors (n=26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/secinto the common hepatic artery and a CT scan was acquired 12 sec after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images.320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.
|