2013 Fiscal Year Final Research Report

Establishment of procedures in stereotactic body radiotherapy for liver cancer

Research Project

  • PDF
Project/Area Number 23791409
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Radiation science
Research InstitutionKyoto University

Principal Investigator

MATSUO Yukinori  京都大学, 医学(系)研究科(研究院), 講師 (80456897)

Project Period (FY) 2011 – 2013
Keywords肝臓癌 / 放射線治療
Research Abstract

A treatment flow in stereotactic body radiotherapy (SBRT) for liver cancer has been established thorough the present research. The flow includes insertion of a fiducial marker, optimal conditions for simulation CT, treatment planning and dose calculation, and dynamic tumor tracking irradiation. The present research adds a treatment option of SBRT to liver cancer. That can play an important role in cancer treatment in Japan. However, this research could not provide optimal procedures in follow-up after liver SBRT, and future research might be warranted.

  • Research Products

    (21 results)

All 2014 2013 2012 2011 Other

All Journal Article (10 results) Presentation (9 results) Book (2 results)

  • [Journal Article] 肝腫瘍に対するリアルタイムモニタリング下動体追尾照射の初期経験2014

    • Author(s)
      飯塚裕介,松尾幸憲,中村光宏, et al.
    • Journal Title

      定位的放射線治療

      Volume: 18 Pages: 9-16

  • [Journal Article] Differences in dose-volumetric data between the analytical anisotropic algorithm and the x-ray voxel Monte Carlo algorithm in stereotactic body radiation therapy for lung cancer2013

    • Author(s)
      Mampuya WA, Matsuo Y, Nakamura A, et al.
    • Journal Title

      Med Dosim

      Volume: 38(1) Pages: 95-9

    • DOI

      10.1016/j.meddos.2012.07.007

  • [Journal Article] Interfraction variation in lung tumor position with abdominal compression during stereotactic body radiotherapy2013

    • Author(s)
      Mampuya WA, Nakamura M, Matsuo Y, et al.
    • Journal Title

      Med Phys

      Volume: 40(9) Pages: 091718

    • DOI

      10.1118/1.4819940

  • [Journal Article] Guidelines for respiratory motion management in radiation therapy2013

    • Author(s)
      Matsuo Y, Onishi H, Nakagawa K, et al.
    • Journal Title

      J Radiat Res

      Volume: 54(3) Pages: 561-8

    • DOI

      10.1093/jrr/rrs122

  • [Journal Article] Differences in the dose-volume metrics with heterogeneity correction status and its influence on local control in stereotactic body radiation therapy for lung cancer2013

    • Author(s)
      Ueki N, Matsuo Y, Shibuya K, et al.
    • Journal Title

      J Radiat Res

      Volume: 54(2) Pages: 337-43

    • DOI

      10.1093/jrr/rrs084

  • [Journal Article] Preliminary Report of Late Recurrences, at 5 Years or More, after Stereotactic Body Radiation Therapy for Non-small Cell Lung Cancer2012

    • Author(s)
      Matsuo Y, Shibuya K, Nagata Y, et al.
    • Journal Title

      J Thorac Oncol

      Volume: 7(2) Pages: 453-6

    • DOI

      10.1097/JTO.0b013e31823c5b29

  • [Journal Article] Dose-volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer2012

    • Author(s)
      Matsuo Y, Shibuya K, Nakamura M, et al.
    • Journal Title

      Int J Radiat Oncol Biol Phys

      Volume: 83(4) Pages: e545-9

    • DOI

      10.1016/j.ijrobp.2012.01.018

  • [Journal Article] Prognostic factors in stereotactic body radiotherapy for non-small-cell lung cancer2011

    • Author(s)
      Matsuo Y, Shibuya K, Nagata Y, et al.
    • Journal Title

      Int J Radiat Oncol Biol Phys

      Volume: 79(4) Pages: 1104-11

    • DOI

      10.1016/j.ijrobp.2009.12.022

  • [Journal Article] The Impact of Abdominal Compression on Outcome in Patients Treated with Stereotactic Body Radiotherapy for Primary Lung Cancer

    • Author(s)
      Mampuya WA, Matsuo Y, Ueki N, et al.
    • Journal Title

      J Radiat Res

      Volume: (in press)

    • DOI

      10.1093/jrr/rru028

  • [Journal Article] Intra- and interfractional variations in geometric arrangement between lung tumours and implanted markers

    • Author(s)
      Ueki N, Matsuo Y, Nakamura M, et al.
    • Journal Title

      Radiother Oncol

      Volume: (in press)

    • DOI

      10.1016/j.radonc.2014.01.014

  • [Presentation] Dynamic Tumor Tracking Radiotherapy with Real-Time Monitoring using Vero4DRT2013

    • Author(s)
      Matsuo Y, Ueki N, Takayama K, et al.
    • Organizer
      15th World Conference on Lung Cancer
    • Place of Presentation
      Sydney, Australia
    • Year and Date
      20131027-30
  • [Presentation] Stereotactic Body Radiotherapy for the Lung2013

    • Author(s)
      Matsuo Y.
    • Organizer
      37th Annual MD Anderson Radiation Oncology/Gilbert H. Fletcher Society Meeting
    • Place of Presentation
      The Westin Miyako Kyoto, Kyoto, Japan
    • Year and Date
      20130418-19
  • [Presentation] Dynamic Tumor Tracking Irradiation with Real-time Monitoring using Vero4DRT (MHI-TM2000)2013

    • Author(s)
      Matsuo Y.
    • Organizer
      GAP 2013 Conference
    • Place of Presentation
      MD Anderson Cancer Center, Houston, TX, USA
    • Year and Date
      2013-04-03
  • [Presentation] Vero4DRTを用いたリアルタイムモニタリング下の動体追尾放射線治療2013

    • Author(s)
      松尾幸憲
    • Organizer
      第26回日本高精度放射線外部照射研究会
    • Place of Presentation
      京都テルサ、京都
    • Year and Date
      2013-02-23
  • [Presentation] Image-guided Radiotherapy and Dynamic Tumor Tracking with Real-time Monitoring using Vero4DRT (MHI-TM2000)2012

    • Author(s)
      Matsuo Y.
    • Organizer
      The 6th S. Takahashi Memorial Symposium and the 6th Japan-US Cancer Therapy International Joint Symposium
    • Place of Presentation
      広島国際会議場、広島, Japan
    • Year and Date
      20120719-21
  • [Presentation] An Initial Experience of Dynamic Tumor Tracking Irradiation with Real-time Monitoring using Vero4DRT (MHI-TM2000)2012

    • Author(s)
      Matsuo Y, Sawada A, Ueki N, et al.
    • Organizer
      ESTRO 31. CCIB, Barcelona, Spain
    • Place of Presentation
      Spain
    • Year and Date
      20120509-13
  • [Presentation] Dynamic Tumor Tracking with Real-time Monitoring using a Gimbaled Linac of Vero4DRT (MHI-TM2000)2012

    • Author(s)
      Matsuo Y, Hiraoka M.
    • Organizer
      EPI2k12. Four Points by Sheraton, Daring Harbour, Sydney, Australia
    • Place of Presentation
      Australia
    • Year and Date
      20120312-14
  • [Presentation] 肺癌定位放射線治療における呼吸性移動対策 : MHI-TM2000(Vero)を用いた動体追尾照射を中心にシンポジウム2「高精度放射線治療の現状と今後の展望」2012

    • Author(s)
      松尾幸憲
    • Organizer
      第24回日本高精度放射線外部照射研究会
    • Place of Presentation
      パシフィコ横浜
    • Year and Date
      20120000
  • [Presentation] Dynamic Tumor Tracking Irradiation with Real-time Monitoring using Vero4DRT (MHI-TM2000)2012

    • Author(s)
      Matsuo Y, Sawada A, Ueki N, et al.
    • Organizer
      The 4th Japan-Korea-China Trilateral Symposium on Radiation Oncology
    • Place of Presentation
      東京国際フォーラム、東京
    • Year and Date
      2012-11-23
  • [Book] 体幹部定位放射線治療後の晩期再発. 日本臨牀. 2013;71(増刊号6)2013

    • Author(s)
      松尾幸憲
    • Total Pages
      507-10
    • Publisher
      日本臨牀
  • [Book] Stereotactic Body Radiotherapy for the Lung, De Salles AAF, Gorgulho A, Agazaryan N, et al., eds. Shaped Beam Radiosurgery.2011

    • Author(s)
      Matsuo Y, Shibuya K, Narabayashi M, Hiraoka M
    • Total Pages
      267-277
    • Publisher
      Springer Berlin Heidelberg

URL: 

Published: 2015-06-25  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi