2012 Fiscal Year Final Research Report
Development of time jitter monitor between electron accelerator and synchronized laser by using frequency decoded EO sampling method.
Project/Area Number |
24651097
|
Research Category |
Grant-in-Aid for Challenging Exploratory Research
|
Allocation Type | Multi-year Fund |
Research Field |
Quantum beam science
|
Research Institution | The University of Tokyo |
Principal Investigator |
IWASAKI Atsushi 東京大学, 大学院・理学系研究科, 特任助教 (30447073)
|
Project Period (FY) |
2012
|
Keywords | 量子ビーム計測手法 |
Research Abstract |
In order to improve the synchronization between the electron linac and ultra-short pulse laser, jitter timing monitor based on the electro-optic sampling technique was developed and examined. The resulting timing jitter was estimated to be200 fs, and the synchronization was stabilized by introducing feed back of the timing drift to the laser trigger circuit in long time scale.
|
Research Products
(10 results)