• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2014 Fiscal Year Final Research Report

Study on development of best selection method for domestic air-conditioner focused on coefficient of performance in use

Research Project

  • PDF
Project/Area Number 24656333
Research Category

Grant-in-Aid for Challenging Exploratory Research

Allocation TypeMulti-year Fund
Research Field Architectural environment/equipment
Research InstitutionNiigata University

Principal Investigator

AKABAYASHI Shin-ichi  新潟大学, 自然科学系, 教授 (70192458)

Co-Investigator(Kenkyū-buntansha) SAKAGUCHI Jun  新潟県立大学, 国際地域学部・国際地域学科, 教授 (90300079)
Project Period (FY) 2012-04-01 – 2015-03-31
Keywords住宅用エアコン / 最適選定法 / COPマトリックス / COP測定法
Outline of Final Research Achievements

In this study, we developed a simple calorie meter to carry out temperature adjustment, and used it in analysis of the relationships among COP, heating and cooling load and outside air temperature. We constructed “COP MATRIX” using a database of the measurement results. Heat load calculation was performed for detached housing model of the residential standard model of the Architectural Institute of Japan. Annual COP was calculated from the result of heat load by collation with the computed COP matrix, which was measured by the outside air temperature each time for the standard meteorological data. COP matrixes divided by supply flow rate of air conditioner are measured by COP-measuring method which controls quantity of passing air of air conditioner constantly. Composited COP matrix is constructed by comparison of COP matrixes divided by supply flow rate.

Free Research Field

建築都市環境工学

URL: 

Published: 2016-06-03  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi