2013 Fiscal Year Final Research Report
Microdosimetry in Metal Particle Dispersion System
Project/Area Number |
24791366
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Multi-year Fund |
Research Field |
Radiation science
|
Research Institution | Shizuoka Cancer Center Research Institute |
Principal Investigator |
KONNO Masahiro 静岡県立静岡がんセンター(研究所), その他部局等, その他 (60466654)
|
Project Period (FY) |
2012-04-01 – 2014-03-31
|
Keywords | 金属コロイド / ナノ粒子 / 線量測定 / マイクロドシメトリー / モンテカルロ計算 / 放射線増感剤 |
Research Abstract |
The aim of this study is to obtain basic physical data for radio sensitizer containing metal nanoparticles. X-ray from medical linear accelerator is irradiated to metal materials including plate, foil, and colloidal solution. Secondary electrons were measured with Gafchromic films with dedicated measurement system. The amount and energy distribution of generated secondary electrons were estimated with help of Monte Carlo calculation. And fluorescence intensity from radiation-induced active oxygen species is measured with fluorescent reagent. Quantitative evaluation including the size and concentration of metal nanoparticles is next step.
|