2015 Fiscal Year Final Research Report
A study on a method for planning a water-saving toilet compatible drainage piping system
Project/Area Number |
25289201
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Partial Multi-year Fund |
Section | 一般 |
Research Field |
Architectural environment/Equipment
|
Research Institution | Kanto Gakuin University |
Principal Investigator |
Otsuka Masayuki 関東学院大学, 建築・環境学部, 教授 (20288088)
|
Co-Investigator(Kenkyū-buntansha) |
ENDO Tomoyuki 関東学院大学, 建築・環境学部, 准教授 (90385534)
|
Project Period (FY) |
2013-04-01 – 2016-03-31
|
Keywords | 給排水衛生設備 / 節水形トイレ / 排水設備システム / 排水横管 / 搬送性能 / 搬送特性 / シミュレーション / CFD |
Outline of Final Research Achievements |
The following matters have been clarified, which contribute to planning and designing a piping system for a building drainage system with a water-saving toilet installed thereto, in terms of ensuring hygiene and safety. ① The prediction of carrying distances of waste, toilet paper, etc., in relation to the decline of carrying performance in the horizontal drainpipe, followed by the development of a simulation tool conducive to piping design support. ② The experimental evaluation of how a piping system affects the drainage performance of a drainage stack system, followed by the clarification of applicability of a water-saving toilet to the piping system. ③ The clarification of how the speed of external wind in the stack vent pipe (vent cap) and ventilation facilities affect the trap of the water-saving toilet.
|
Free Research Field |
建築学
|