2017 Fiscal Year Final Research Report
Development of a method of reducing heat strain at recovery work for destroyed Nuclear Power Plant and construction work in Summer
Project/Area Number |
25293155
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Partial Multi-year Fund |
Section | 一般 |
Research Field |
Hygiene and public health
|
Research Institution | National Institute of Occupational Safety and Health,Japan |
Principal Investigator |
Sawada Shin-ichi 独立行政法人労働者健康安全機構労働安全衛生総合研究所, 人間工学研究グループ, 特任研究員 (00167438)
|
Co-Investigator(Kenkyū-buntansha) |
時澤 健 独立行政法人労働者健康安全機構労働安全衛生総合研究所, 人間工学研究グループ, 主任研究員 (00454083)
永島 計 早稲田大学, 人間科学学術院, 教授 (40275194)
奥野 勉 独立行政法人労働者健康安全機構労働安全衛生総合研究所, 人間工学研究グループ, 特任研究員 (90332395)
齊藤 宏之 独立行政法人労働者健康安全機構労働安全衛生総合研究所, 人間工学研究グループ, 上席研究員 (10332397)
|
Research Collaborator |
OKA Tatsuo
YASUDA Akinori
TAI Tetsuo
SON Su-young
IDA Hirobumi
NAKAYAMA Kazumi
WADA Jun
|
Project Period (FY) |
2013-04-01 – 2018-03-31
|
Keywords | 熱中症 / 暑熱ストレイン軽減手法 / 暑熱ストレス軽減手法 / 夏期屋外酷暑作業 / 送風クーリング / 水スプレー / WBGT指数 / ミストファン |
Outline of Final Research Achievements |
To reduce heat stress and strain at recovery work for the destroyed Nuclear Power Plant and construction work in summer, we developed a cooling method using a blower fan and a water spray (plus additional water immersion of extremities) and demonstrated its certain effectiveness in the laboratory experiment. Therefore, to examine the effectiveness at real outdoor work sites next, a commercially available mist fan having a cooling mechanism similar to our method was substituted for our experimental model to investigate how much effective the cooling method is for reducing the environmental heat stress at a construction work site. The study showed that the combined use of fan and water spray drastically decreased the WBGT value which is an indicator of heat stress suggesting that this method has remarkable cooling effect for reducing the environmental heat stress at outdoor work. Furthermore, the optimum distance between the object to be cooled and the mist fan could also be identified.
|
Free Research Field |
社会医学、産業医学、温熱生理衛生学、労働安全衛生学、労働生理学、環境人間工学、衛生公衆衛生学
|