2015 Fiscal Year Final Research Report
Optimal application of advanced CT technology for the diagnosis and management of lung cancer.
Project/Area Number |
25461818
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | Kyoto University |
Principal Investigator |
KUBO TAKESHI 京都大学, 医学(系)研究科(研究院), 助教 (20464216)
|
Project Period (FY) |
2013-04-01 – 2016-03-31
|
Keywords | エックス線 / CT / 肺癌 / X線線量低減 |
Outline of Final Research Achievements |
Effectiveness of advanced area detector CT technology to lung cancer management was assessed in terms of motion analysis and radiation dose reduction. Kinematic assessment was shown to be feasible by applying CT iterative reconstruction method. Low dose CT images can be applicable without decrease in diagnostic accuracy of common abnormality found in chest CT.
|
Free Research Field |
放射線診断学
|