2015 Fiscal Year Final Research Report
Novel treatment method of stereotactic body radiotherapy for moving tumor with 320 row MDCT and Airbag system.
Project/Area Number |
25861098
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Multi-year Fund |
Research Field |
Radiation science
|
Research Institution | Osaka University |
Principal Investigator |
Suzuki Osamu 大阪大学, 医学(系)研究科(研究院), 寄附講座准教授 (30644778)
|
Project Period (FY) |
2013-04-01 – 2016-03-31
|
Keywords | 体幹部定位照射 |
Outline of Final Research Achievements |
In the treatment planning of stereotactic radiotherapy for moving tumor such as lung cancer or liver tumor, it is essential to acquire the actual tumor motion and reflect to the dedicated planning. We utilize the MDCT with 320 row for the acquisition of 4DCT in lung and liver. Especially in the liver, dynamic enhanced 4DCT was enabled in that setting which resulted in clear tumor delineation of HCC and metastasis.
|
Free Research Field |
放射線治療学
|