2015 Fiscal Year Final Research Report
Assessment of muscle damage recovery by electromyographic recording using implanted soft flexible electrodes
Project/Area Number |
26560364
|
Research Category |
Grant-in-Aid for Challenging Exploratory Research
|
Allocation Type | Multi-year Fund |
Research Field |
Sports science
|
Research Institution | Tohoku University |
Principal Investigator |
|
Co-Investigator(Renkei-kenkyūsha) |
TORIMITSU Keiichi 東北大学, 大学院工学研究科, 教授 (00393728)
|
Project Period (FY) |
2014-04-01 – 2016-03-31
|
Keywords | ソフト電極 / 筋電図 / 自由行動 / 筋損傷 / 筋再生 |
Outline of Final Research Achievements |
Flexible silk electrode fabricated based on PEDOT was surgically inserted to record the electromyographic (EMG) activity of rat gastrocnemius muscle. By means of implanted telemetric system, stable EMG activity of a free moving unrestrained and unanesthesized rat was recorded over the period of 3 weeks. EMG activity after the muscle damage induction by intramusclular injection of venom toxin, cardiotoxin, was recorded over the period of 1 week. The observed EMG changes was in accordance with the time course of previously known histological damage and recovery.
|
Free Research Field |
体力科学
|