Outline of Final Research Achievements |
We have developed a measurement system utilizing a cooled pickup coil and a SQUID pico-voltmeter for magnetic particle imaging (MPI). The magnetic field noise spectrum of the system was as low as 9 fT at the measurement frequency of 9 kHz. The spatial resolution in MPI was improved by using a gradient field of 0.2 T/m. Using the developed system, we obtained a clear contour map of the signal field from the magnetic particles. Then, the field map was analyzed to estimate the position of magnetic particles. We demonstrated the detection of two MNPs samples located at the depth of 50 mm below the sensor with a spatial resolution of about 10 mm.
|