1986 Fiscal Year Final Research Report Summary

Optimum Design of Knee Prostheses with High Performance Similar to Natural Knee Joints

Research Project

Project/Area Number 60550109
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 機械要素
Research InstitutionKyushu University

Principal Investigator

MURAKAMI Teruo  Kyushu University, 工学部, 助教授 (90091347)

Co-Investigator(Kenkyū-buntansha) OHTSUKI Nobuo  Kyushu University, 工学部, 助手 (60127991)
HIROKAWA Shunji  Kyushu University, 教養部, 助教授 (80150374)
Project Period (FY) 1985 – 1986
KeywordsArtificial Joints / Knee Prostheses / Tribology / Biotribology / Biomechanics / Lubrication Engineering / Optimum Design / 関節シミュレータ
Research Abstract

The object of this research is to develop the approaches for the optimum design for knee prostheses with high performance similar to natural knee joints. What we are aiming principally at is to establish fluid film formation in knee prostheses.
The following methods were carried out.
1. Three-dimensional analysis for the contact conditions in knee joints
Firsty, the three-dimensional geometric analysis based on the CAD theory was applied to natural knee joints, since our trial knee prosthesis model has similar geometry to the natural joint. The contact points and load-carrying characteristics in the flexed and extended conditions were obtained by using this mathematical expression for curved articular surfaces.
Secondary, three-dimensional photoelastic freezing method was applied to investigate the contact stress distribution in the extended position. It was shown that the articular cartilage and meniscus remarkably reduced the contact stresses in the subchondral bones.
2. Knee joint simulator test
To evaluate the fluid film formation in knee prostheses under walking condition, the knee joint simulator was developed and used for the measurement of electric contact resistance and friction between femoral and tibial components. In a knee prosthesis with an elastomeric tibial component, elastohydrodynamic film was considerably formed even during the loading stance phase, whereas in a prosthesis with a polyethylene tibial one, slight fluid film formation was observed only immediately after the heel strike except during the swing phase. In the former, the film thickness decreases during the stance phase and generally becomes minimum at the peak load just before the toe off, and recovers to the previous level during the swing phase. It is suggested from the experimental results that the knee prosthesis with complient artificial cartilage is capable of improving the fluid film formation with adequate lubricants.

  • Research Products

    (11 results)

All Other

All Publications (11 results)

  • [Publications] Teruo Murakami: Proc.JSLE Int.Tribology Conf.363-368 (1985)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 村上輝夫: 整形外科バイオメカニクス. 7. 125-130 (1986)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 村上輝夫: 日本機械学会論文集. 53. 151-156 (1987)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 広川俊二: 計測自動制御学会論文集. 21. 411-417 (1985)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 広川俊二: 計測自動制御学会論文集. 22. 580-587 (1986)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 広川俊二: 計測自動制御学会論文集. 23. 79-85 (1987)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Teruo Murakami: "Effect of Molecular Weight Distribution of Mineral Oils on Lubricating Performance under Sliding Contact Condition" Proc. JSLE Int. Tribology Conf.363-368 (1985)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Teruo Murakami: "Friction and Wear Characteristics of Artificial Joint Materials under Sliding Contact Conditions" Proc. 1985 Annual Meeting of Japanese Soc. Orthop. Biomech.7. 125-130 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Teruo Murakami: "The Evaluation of Lubricating Film Formation in Knee Prostheses in a Knee Joint Simulator" Trans. JSME. 53. 151-156 (1987)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Shunji Hirokawa: "Analytical Study on Three-Dimensional Model of Femoropatellar Joint" Trans. Soc. Instrument and Control Engineers. 21. 411-417 (1985)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Shunji Hirokawa: "Analytical Study on Three-Dimensional Model of Femoropatellar Joint -- Trajectory Pattern and Load Bearing Capacity on the Contact Points --" Trans. Soc. Instrument and Control Engineers. 22. 580-587 (1986)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1988-11-10  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI