• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1987 Fiscal Year Final Research Report Summary

DEVELOPMENT OF A FOURIER-TRANSFORM IOC CYCLOTRON RECONANCE MASS SPECETROMOTER FOR ISOTOPIC ANALYSIS

Research Project

Project/Area Number 61840019
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field 分析・地球化学
Research InstitutionTOKYO INSTITUTE OF TECHNOLOGY

Principal Investigator

MATSUO Sadao  TOKYO INSTITUTE OF TECHNOLOGY, 理学部, 教授 (30015490)

Co-Investigator(Kenkyū-buntansha) SHINOHARA Hiroshi  TOKYO INSTITUTE OF TECHNOLOGY, 理学部, 助手 (30196406)
Project Period (FY) 1986 – 1987
KeywordsION CYCLOTRON RESONANCE / RESIDUAL GAS ANALYSIS / ISOTOPERATION / MICROCOMPUTER / FOURIER TRANSFORM / 質量分析
Research Abstract

THE PURPOSE OF THE PROJECT IS TO CONSTRUCT THE ION CYCLOTRON RESONANCE MASS SPECTROMETER BY WHICH THE PRECISION IN ISOTOPRERATION MEASUREMENT CANBE EVALUATED WECOMPLETED THE MACHINE FEATURED AS FOLLOWS.
(1) A PERMANENT MAGNET IS IS ADOPTED TO OBTAIN THE HOMOGENEOUS MAGNETIC FEILD WITH THE STRENGTH OF 0.3 TESLA. THE POLE GAP WAS 40 MM.
(2) THE VACUUM SYSTEM WAS COMPOSED OF THE HIGH VCAPACITY OIL DIFFUSION PUMP. THE ULTIMATE VACUUM WAS 10^<-7>PASCAL.
(3) A COMMERCIAL WAVE GENERA TOR WITH THE DERECT DIGITAL SYNTHESIZER PEINCIPLE WAS USED FOR EXCITATION OF IONS.
(4) A VARIABLE GAS LEAK VALVE WAS ADOPTED FOR FUTURE EXPANSION OF INLET GAS HANDLING SYSTEM. THE IMMEDIATE TARGET IONS WOUD BE THE RESIDUAL GAS SPECIES.^<12>CO AND^<13>CO.
(5) COMMERCIALLY AVALILABLE ADD-ON CIRCUIT BOARDS FOR MICROCOMPUTER WERE UTILISED FOR REALISATION OF THE FUNCTION OF ANALOG-TO-DEGITAL CONVERSION OF THE SIGNAL AND CONTROL PULSE GENERATION OF THE SYSTEM.
(6) A SOFTWAREPACKAGE COMMERCIALLY AVAILABEL FOR MICROCOMPUTER FACILITATED THE DEVELOPMENT OF THE CONTROL AND MEASUREMENT PROGRAM FOR THE EXPERIMENT THE SOFTWARE WAS ORIGINALLY DEVELOPED FOR USING THE MICROCOMPUTER AS THE FFT ANALYSER.

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 大隅多加志: 質量分析. 36. (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] TAKASHI OHSUMI: "APPLICATION OF FOURIER TRANSFROM MASS SPECTROMETER TO ISOTOPE RATIO MEASUREMENT" MASS SPECTROSCOPY. 36. (1988)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1989-03-30  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi