• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1988 Fiscal Year Final Research Report Summary

Basic Study on Development of Ultrasensitive Enzyme Immunoassay for Antibodies

Research Project

Project/Area Number 62570119
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field General medical chemistry
Research InstitutionMiyazaki Medical College

Principal Investigator

ISHIKAWA Eiji  Department of Biochemistry, Miyazaki Medical College Kiyotake, Miyazaki 889-16, Japan, 医学部, 教授 (40029939)

Co-Investigator(Kenkyū-buntansha) KOHNO Takeyuki  Department of Biochemistry, Miyazaki Medical College Kiyotake, Miyazaki 889-16,, 医学部, 助手 (50178224)
Project Period (FY) 1987 – 1988
KeywordsInsulin / Anti-insulin IgG / Enzyme immunoassay / Antibody / Radioimmunoassay / 糖尿病
Research Abstract

An ultrasensitive enzyme immunoassay technique for anti-insulin IgG in serum was developed. Test serum was subjected to successive processes of incubation with insulin, dextran-charcoal treatment to remove free insulin, precipitation of insulin-anti-insulin IgG complex by polyethylene glycol, acid-treatment of the precipitates to inactivate anti-insulin IgG and measurement of insulin by ultrasensitive sandwich enzyme immunoassay. The detection limit of anti-insulin IgG in serum was 10- to 30-fold lower than that by radioimmunoassay using ^<125>I-labeled insulin and 1,000- to 3,000-fold lower than that by the conventional enzyme immunoassay, in which an insulin-coated polystyrene ball was incubated with test serum and (anti-IgG) Fab'-peroxidase conju-gate. By this technique, anti-insulin IgG was demonstrated in most (89 %) of serum samples from diabetic patients who had been treated with insulin for 0.6-10 months, while only a small proportion (3 %) was positive by the conventional enzy … More me immunoassay. Anti-insulin IgG was also demonstrated in some of type I diabetic patients before treatment, although at very low levels. In order to measure serum antibodies for other antigens with high sensitivity, an alternative technique was also developed using anti-insulin IgG as an antibody model. Test serum was incubated with insulin and applied to a column of (anti-IgG) IgG-Sepharose 4B to separate insulin-anti-insulin IgG complex from free insulin. Insulin was eluted from the column with acid and, after inactivation of anti-insulin IgG, measured by ultrasensitive sandwich enzyme immunoassay. The sensitivity was satisfactory, and the applicability of this technique was supported by the finding that the antigenicity of antigens such as growth hormone and thyroid-stimulating hormone was retained after acid-treatment. For the measurement of anti-hapten antibodies, it has been concluded from various considerations that techniques distinct from previously developed ones remain to be developed. Less

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] Eiji Ishikawa;Takeyuki Kohno: Journal of Clinical Laboratory Analysis. (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Eiji Ishikawa; Takeyuki Kohno: "Department and applications of sensitive enzyme immunoassay for antibodies- A review" Journal of Clinical Laboratory Analysis. (1989)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1990-03-20  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi