An attempt at coronary angiography with a large size monochromatic SR beam

Research Project

Project/Area Number 62870043
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Radiation science
Research InstitutionUniversity of Tsukuba

Principal Investigator

AKISADA Masayoshi  Univ. of Tsukuba, Inst. of Clin. Med., Prof., 臨床医学系放射線, 教授 (90110494)

Co-Investigator(Kenkyū-buntansha) ANNO Izumi  Univ. of Tsukuba, Inst. of Clin. Med., Assist.Prof., 臨床医学系, 講師 (50138707)
SUGISHITA Yasuro  Univ. of Tsukuba, Inst. of Clin. Med., Associate Prof., 臨床医学系, 助教授 (90010131)
HYODO Kazuyuki  高エネルギー研, 放射光実験施設, 助手 (60201729)
ANDOH Masami  高エネルギー研, 放射光実験施設, 教授 (30013501)
HASEGAWA Shin  電気通信大学, 電子工学, 教授 (60017308)
Project Period (FY) 1987 – 1989
KeywordsSynchrotron radiation / Coronary angiography / K-edge / Energy subtraction / Angio-cardiography
Research Abstract

Ischemic heart disease which leads to the cause of sudden death, is the most serious disease in the industrial countries. In Japan, the incidence of heart disease has been ranked next to that of malignant tumor since 1985. The number of death due to ischemic heart disease based on arteriosclerosis of coronary arteries in 1987, have increased 5 times more than that in 1950. The selective coronary angiography is the final diagnostic modality for the ischemic heart disease. But this modality is invasive and costly because a special catheter must be directly inserted into coronary arteries using a special angiographic system, and have hospitalization. Therefore new and safer diagnostic method for ischemic heart disease has been required year by year.
Only k-edge energy subtraction angiography with synchrotron radiation can reveal the coronary artery via the intravenous injection of contrast material. And two dimensional image acquisition system which can demonstrates the images as a conventional cine-angiography, is being constructed at Photon Factory in Tsukuba. This system consists of five elements. 1) Sufficient X-ray flux(Insertion device; Wiggler). 2)High speed energy switching(Above and below K-edge). 3)Beam expansion(Asymmetric reflection on Silicon crystal). 4)High speed image acquisition TV system 5)Image processing.
The experiments with this prototype angiographic system showed that coronary artery could be demonstrated dearly in the animal such as dog. The elements of 3) and 4) were nearly finished. But for the human studies, the most important problems of this system is an insufficient X-ray flux and a high speed energy switching. Insertion device must be developed for a sufficient X-ray flux. And new methods of energy switching might be suitable because mechanical energy switching using the vibration of large silicon crystal might have dynamic problem such as strains of crystal by moment. Further studies will be needed especially in 1)and 2) elements.

  • Research Products

    (13 results)

All Other

All Publications (13 results)

  • [Publications] Akisada M.et al.: "K-edge subtraction angiography using synchrotron radiation" Japanese J.of Medical Imaging and Information Sciences. (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Fukagawa H.et al.: "Real time K-edge subtraction X-ray imaging" Review of Scientific Instrumets. 60(7). 2268-2271 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Nishimura K.et al.: "High-speed image-acquisition system for energy subtraction angiography" Review of Scientific Instruments. 60(7). 2260-2263 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Suwa A.et al.: "X-ray K-edge subtraction television system" Japanese J.Applied Physics. 27(10). 1989-1996 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Akisada M.et al.: "An attempt at angiography with a large size monochromatic SR beam" Nuclear Instruments and Methods in Physics Research. A246. 713-718 (1986)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takeda T.et al: "High speed iodine K-edge subtraction angiography A preliminary experiment with Rats" Medical Imaging Technology. 6(4). 400-406 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 監修:高良和武: "シンクロトロン放射利用技術" サイエンス・フォ-ラム, 417 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Akisada M, et al: "K-edge subtraction angiography using synchrotron radiation." Jpn. J. of Medical Imaging and Information Science. (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Fukagawa H, et al: "Real time k-edge subtraction X-ray imaging." Review of Scientific Instruments. 60. 2268-2271 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Nishimura K, et al: "High speed image acquisition system for energy subtraction angiography." Review of Scientific Instruments. 60. 2260-2263 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Suwa A, et al: "X-ray K-edge subtraction television system." Jpn. J. of Applied Physics. 27. 1989-1996 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Akisada M: "An attempt at coronary angiography with a large size monochromatic SR beam." Nuclear Instruments and Methods in Physics Research. A246. 713-718 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takeda T, et al: "High speed iodine K-edge subtraction angiography; A preliminary experiment with rats." Medical Imaging Technology. 6. 400-406 (1988)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI