1989 Fiscal Year Final Research Report Summary

Experiment of card dosimeter

Research Project

Project/Area Number 62870045
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Radiation science
Research InstitutionKurume University School of Medicine

Principal Investigator

UMEZAKI Noriyoshi  Kurume Univ. Med. Assist. Prof., 医学部, 講師 (10098808)

Co-Investigator(Kenkyū-buntansha) INOUE Kiyoshi  Kyuusyuu Keisokki Scientific Dept. Chief, 科学機器課, 課長
Project Period (FY) 1987 – 1989
KeywordsDosimeter / Effective dose / Silicon photo-diode / energy calibration
Research Abstract

In the first year, we have designed and assembled a preamplifier circuit for a card type dosimeter. Using the preamplifier, we have got gamma-ray spectrum with silicon photo diode for detector. The spectra were compared with those taken by Ge detector system. Energy resolution with silicon detector was 2-3 keV for Am-241 59.5 keV gamma-ray. The preamplifier had a sensitivity of about 1.4x10^<-3>mm^2.
In the following year, we have approved a electronics circuit which can divide a detected photon energy into fifteen division and storage into IC RAM memory card. Data analysis and processing program was also developed. Interface between IC RAM and personal computer has been made on software and hardware. Energy range of each division is adjustable. Because desired energy-range is different in each using circumstance.
In the last year, this year, each components, silicon photo-detector, preamplifier and electronics circuit, are assembled. We are trying to make a dosimeter as small as possible, "CARD DOSIMETER". Our dosimeter has been satisfactory yet. Consumption of preamplifier is somewhat large, so available battery is not so small as occupying tenth volume of whole dosimeter. The thickness of dosimeter must be changed to 15mm, which designed 7mm first.
Using this dosimeter and energy calibration program, we can get practical convenient effective dose on various energy range. This dosimeter will contribute effective dosimetry using card type sensor.

  • Research Products

    (4 results)

All Other

All Publications (4 results)

  • [Publications] 梅崎典良: "医療における放射線管理のための測定の現状と技術的問題" 日本放射線技術学会雑誌. 44. 1528-1534 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Umezaki,Noriyoshi: "The Present and Technical Problems of Dosimetry for Radiation Protection in the Field of Radiology" Jon.J.Radiol.Technol. 8(Special Issue). 1-10 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Umezaki, N. Kawamura, M. Miyagawa, T. Kawamura, S.: "Problems Related to Radiation Measurement Techniques at Medical Instruments" Jpn.J.Radiol. Technol. 44(10).1528-1534(1988).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Umezaki, N. Kawamura, M. Miyagawa, T. Kawamura, S.: "The Present and Technical Problems of Dosimetry for Radiation Protection in the Field of Radiology" Jpn.J.Radiol.Technol. (Sp. Issue), 8(1).1-10(1989).

    • Description
      「研究成果報告書概要(欧文)」より