• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Quantitative Analysis on CT image in maxillofacial Region

Research Project

Project/Area Number 01480463
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 外科・放射線系歯学
Research InstitutionTokyo Medical and Dental University

Principal Investigator

SASAKI Takehito  Tokyo Medical and Dental University, Faculty of Dentistry, Professor, 歯学部, 教授 (90013896)

Co-Investigator(Kenkyū-buntansha) ICHIJYO Takashi  Tokyo Medical and Dental University, Faculty of Dentistry, Professor, 歯学部, 教授 (20013807)
KATO Tuguhisa  Tokyo Medical and Dental University, Faculty of Dentistry, Assistant, 歯学部, 助手 (70095107)
HONDA Eiichi  Tokyo Medical and Dental University, Faculty of Dentistry, Assistant, 歯学部, 助手 (30192321)
佐々木 武仁  東京医科歯科大学, 歯学部, 教授 (90013896)
Project Period (FY) 1989 – 1991
Project Status Completed (Fiscal Year 1991)
Budget Amount *help
¥6,800,000 (Direct Cost: ¥6,800,000)
Fiscal Year 1991: ¥1,700,000 (Direct Cost: ¥1,700,000)
Fiscal Year 1990: ¥1,700,000 (Direct Cost: ¥1,700,000)
Fiscal Year 1989: ¥3,400,000 (Direct Cost: ¥3,400,000)
KeywordsCT scan / Partial volume effect / H. U. value / Cortical bone / Parotid gland / Artifact / 上顎洞内腔 / 粘膜厚さ
Research Abstract

The length, volume and distribution of CT values in the anatomical structures are the fundamental prerequisites for quantitative analysis of CT images in the maxillofacial region. The purpose of this investigation is to analyze the effect of the neighboring anatomical structures on these morphometric values.
1. Length of Anatomical Structures.
The length involved in bone and soft tissue structures of 14 cadavers were measured in both cephalometric and CT images. The maximum width and height of the maxillary sinus obtained from CT images are well correlated to those from cephalograms. The cortical bone thickness of the mandible measured in the CT images are 10-30% less than those in cephalograms. The mucosal thickness of the palate measured in the CT images are about 20% less than that actually measured.
2. Distribution of CT Value in Parotid
A parotid gland was carefully removed from a cadaver with 32 teeth normally erupted and was placed back after wrapped with a sheet of paraffin wax. CT scan was performed for the parotid gland in the cadaver in situ and also in a water phantom. Average CT value in the axial CT image at the cervival plane of the maxilla was equivalent to that of water. However, the CT values were higher in the posterior portion (close to the mastoid process) and lower in the anterior portion (posterior to the madibular ramus) in the gland than those measured in the images of the gland in water.
The CT profile in the coronal plane showed higher CT values for upper portion and lower CT values for lower portion of the gland than those obtained from the images in water. The mesio-lateral profile in the mid-plane of the coronal section indicated that CT values close to the madibular ramus were higher in the 1-2mm length than those measured in the gland in water.
3. Volume of Salivary Gland
The volume estimated from CT images of the cadaver was about 30% larger for both parotid and submandibular glands than those actually measured for the extracted glands.

Report

(4 results)
  • 1991 Annual Research Report   Final Research Report Summary
  • 1990 Annual Research Report
  • 1989 Annual Research Report
  • Research Products

    (28 results)

All Other

All Publications (28 results)

  • [Publications] 佐々木 武仁: "画像診断技術革新の歯科医療に与えるインパクト" Quintessence. 10. 620-628 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] 佐々木 武仁: "画像診断法の最近の技術的進歩ーデジタルラジオグラフィ-ー" 東京都歯科医師会雑誌. 39. 757-768 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] E.Honda et al: "A method for determination of fractal dimensions of sialographic images" Investigative Radiology. 26. 894-901 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] E.Honda et al: "Evaluation of a new type of high sharpness film for skull radiography" Dentomaxillofac.Radiol.20. 59-64 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] M.Ida et al: "Radiographic quality and patient discomfort in sialography:comparison of iohexol with iothalamate" Dentomaxillofac.Radiol.20. 81-86 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] T.Kurabayashi,et al: "Differential diagnosis of submandifular tystic lesions by computed tomography" Dentomaxillofac.Radiol.20. 30-34 (1991)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] T. Sasaki: "Impact of innovation in image technology on clinical dentistry" Quintessence. 10. 6-14 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] T. Sasaki: "Recent progress of image diagnosis. -Digital radiography-." J. Tokyo Dent. Assoc.39. 757-768 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] E. Honda et al: "A method for determination of fractal dimensions of sialographic images" Investigative Radiology. 26. 894-901 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] E. Honda et al: "Evaluation of a new type of high sharpness film for skull radiography" Dentomaxillofac. Radiol. 20. 59-64 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] M. Ida et al: "Radiographic quality and patient discomfort in sialography : comparison of iohexol with iothalamate" Dentomaxillofac. Radiol. 20. 81-86 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] T. Kurabayashi, et al: "Differential diagnosis of submandibular cystic lesions by computed tomography" Dentomaxillofac. Radiol. 20. 30-34 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1991 Final Research Report Summary
  • [Publications] 佐々木 武仁: "画像診断技術革新の歯科医療に与えるインパクト" Quintessence. 10. 620-628 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] 佐々木 武仁: "画像診断法の最近の技術的進歩ーデジタルラジオグラフィ-ー" 東京都歯科医師会雑誌. 39. 757-768 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] E.Honda et al: "A method for determination of fractal dimensions of sialographic" Investigative Radiology. 26. 894-901 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] E.Honda et al: "Evaluation of a new type of high sharpness film for skull radiography" Dentomaxillofac.Radiol.20. 59-64 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] M.Ida et al: "Radiographic quality and patient discomfort in sialography:comparison of iohexol with iothalamate" Dentomaxillofac.Radiol.20. 81-86 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] T.Kurabayashi,et al: "Differential diagnosis of submandifular tyastic lesions by computed tomography" Dentomaxillofac.Radiol.20. 30-34 (1991)

    • Related Report
      1991 Annual Research Report
  • [Publications] 佐々木 武仁: "歯科領域の放射線検査の安全性と正当性" 日本歯科医師会雑誌. 43. 364-372 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] E・Honda,et al: "Dental Radiographic Signs Characteristic to HallermannーStreiff Syndrome." Oral Surg.Oral Med.Oral Path.70. 121-125 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] 誉田 栄一,芝崎 初江,佐々木 武仁: "二等分法撮影による全顎口内法X線写真(10枚法)の失敗頻度の客観的評価" 歯科放射線. 30. 9-15 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] Kurabayashi,T.,Oda,M.Sasaki,T.: "Differential Diagnosis of Submandibular Cystic Lesions by Computed Tomography" Dentomasillofac.Radiol.20. 30-34 (1991)

    • Related Report
      1990 Annual Research Report
  • [Publications] 加藤 二久: "骨ミネラル量分布測定のための定量的X線画像" 日本医放会誌. 50. 1127-1138 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] 佐々木武仁: "歯・顎・顔面領域における画像診断の進歩と放射線検査の正当性" 東京都歯科医師会雑誌. 37. 448-456 (1989)

    • Related Report
      1989 Annual Research Report
  • [Publications] 井田瑞技: "X線写真上で石灰化を認めた顎下線のCarcinoma in pleomorphic adenomaの一症例" 歯科放射線. 29. 63-68 (1989)

    • Related Report
      1989 Annual Research Report
  • [Publications] E.Honcla: "Dental radiographic signs characteristic to the Hallermann-Streiff syndrome" OS,OM&OP. (1990)

    • Related Report
      1989 Annual Research Report
  • [Publications] T.Kato: "Theoretical analysis of image formation process in quantitative dual-energy subtraction in single exposure." Nippon Acta Radiol. 49. 1152-1167 (1989)

    • Related Report
      1989 Annual Research Report
  • [Publications] 渡部敦: "顎顔面領域における計量画像診断の基礎" 歯科放射線. 29. 186 (1989)

    • Related Report
      1989 Annual Research Report

URL: 

Published: 1989-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi