Numerical Fluid-Mechanical Analysis of Accuracy of Ultrasound Doppler Catheter Velocimetry for Measurement of Blood Flow Velocity

Research Project

Project/Area Number 01571241
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 医学一般
Research InstitutionKawasaki College of Allied Health Professions

Principal Investigator

KAGIYAMA Mitsuyasu  Kawasaki College of Allied Health Professions, Department of Medical Electronics, Lecturer, 医用電子技術科, 講師 (60204335)

Co-Investigator(Kenkyū-buntansha) KAJIYA Fumihiko  Kawasaki College of Allied Health Professions, Department of Medical Electronics, 医用電子技術科, 教授 (70029114)
MITO Keiichiro  Kawasaki College of allied Health Professions, Department of Medical Electronics, 医用電子技術科, 助教授 (40078027)
JIKUYA Kazuaki  Kawasaki College of Allied Health Professions, Department of Medical Electronics, 医用電子技術科, 講師 (90206350)
Project Period (FY) 1989 – 1990
Project Status Completed (Fiscal Year 1990)
Budget Amount *help
¥1,600,000 (Direct Cost: ¥1,600,000)
Fiscal Year 1990: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1989: ¥800,000 (Direct Cost: ¥800,000)
KeywordsNumerical fluid-mechanics / Ultrasound Doppler catheter / Simulation / 数値流体力学 / 冠血管
Research Abstract

In the previous model-tube experiment, we indicated that 20-MHz ultrsound Doppler catheter velocimetry provides a reliable measure for evaluation relative velocity changes, although it underestimates the blood velocity. To explain this result fluid mechanically, we analyzed the influence of the catheter insertion on the accuracy of Doppler catheter velocimetry by solving numerically the equations of motion for blood flow in a catheterized tube.
[Method] A catheterized tube was modeled by a rigid cylindrical tube into which a cylindrical catheter is inserted coaxially. We assumed that fluid is incompressible and Newtonian, and that flow is axisymmetric in the tube. Velocity distribution of the steady flow in the tube was calculated by solving the vorticity and stream function equations transformed from two dimensional Navier-Stokes equations and continuity equation in a cylindrical coordinate system. Dufort and Frankel's method was used to solve the velocity equation, and Liepmann's method was used to solve the stream function iteratively.
[Results] Calculations were carried out under the assumption that (1) the flow direction is away from the catheter tip, (2) the inner diameter of the vessel is 7mm, (3) the size of the catheter is 1mm and (4) the Reynolds number is 400. The velocity profile was M-shaped or blunt pattern across the vessel at 1-3 tubular diameter from the catheter tip. The center line velocity was depressed up to 8-10 tubular diameters distal to the catheter tip.
[Concluding Remarks] The M-shaped or blunt flow pattern may be the major cause for greater under-estimation of away flow velocity than that of toward-flow velocity.

Report

(3 results)
  • 1990 Annual Research Report   Final Research Report Summary
  • 1989 Annual Research Report
  • Research Products

    (11 results)

All Other

All Publications (11 results)

  • [Publications] 忠岡 信一郎: "ドプラカテ-テルを用いた冠血流計測の問題点と臨床応用" 医用電子と生体工学. 27. 385-385 (1989)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 鍵山 光庸: "超音波パルスドプラ血流計の計測精度に関する理論解析" 医用電子と生体工学. 27. 383-383 (1989)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] Shinichiro Tadaoka: "Accuracy of 20ーMHz Doppler Catheter Coronary Artery Velocimetry for Measurement of Coronary Blood Flow Velocity" Catheterization and Cardiovascular Diagnosis. 19. 205-213 (1990)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 鍵山 光庸: "冠動脈計測用超音波ドプラカテ-テルの計測精度" 医用電子と生体工学. 28. 499-499 (1990)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] Shinichiro Tadaoka: "Accuracy of 20-MHz Doppler Catheter Coronary Artery Velocimetry for Measurement of Coronary Blood Flow Velocity" Catheterization and Cardiovascular Diagnosis. 27. 205-213 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1990 Final Research Report Summary
  • [Publications] 忠岡 信一郎: "ドプラカテ-テルを用いた冠血流計測の問題点と臨床応用" 医用電子と生体工学. 27. 385-385 (1989)

    • Related Report
      1990 Annual Research Report
  • [Publications] 鍵山 光庸: "超音波パルスドプラ血流計の計測精度に関する理論解析" 医用電子と生体工学. 27. 383-383 (1989)

    • Related Report
      1990 Annual Research Report
  • [Publications] Shinichiro Tadaoka: "Accuracy of 20ーMHz Doppler Catheter Coronary Artery Velocimetry for Measurement of Coronary Blood Flow Velocity" Catheterization and Cardiovascular Diagnosis. 19. 205-213 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] 鍵山 光庸: "冠動脈計測用超音波ドプラカテ-テルの計測精度" 医用電子と生体工学. 28. 499-499 (1990)

    • Related Report
      1990 Annual Research Report
  • [Publications] 忠岡信一郎: "20MHzドプラカテ-テルを用いた冠血流計測の問題点と臨床応用" 医用電子と生体工学. 27,(特別号). 385 (1989)

    • Related Report
      1989 Annual Research Report
  • [Publications] 鍵山光庸: "冠動脈計測用超音波ドプラカテ-テルの血流計測精度" 医用電子と生体工学. 28,(特別号). (1990)

    • Related Report
      1989 Annual Research Report

URL: 

Published: 1989-04-01   Modified: 2016-04-21  