• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

STUDIES ON REGIONAL FREQUENCY DISTRIBUTION OF V/Q RATIO AT REST AND DURING EXERCISE

Research Project

Project/Area Number 04670681
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field Radiation science
Research InstitutionOSAKA MEDICAL COLLEGE

Principal Investigator

NARABAYASHI Isamu  OSAKA MEDICAL COLLEGE, PROFESSOR OF DEPARTMENT OF RADIOLOGY, 医学部, 教授 (60122438)

Co-Investigator(Kenkyū-buntansha) TATSU Yoshimitsu  OSAKA MEDICAL COLLEGE, ASSISTANT OF DEPARTMENT OF RADIOLOGY, 医学部, 助手 (50227097)
ADACHI Itaru  OSAKA MEDICAL COLLEGE, ASSISTANT OF DEPARTMENT OF RADIOLOGY, 医学部, 講師 (70175884)
NISHIGAKI Hiroshi  OSAKA MEDICAL COLLEGE, ASSISTANT OF DEPARTMENT OF RADIOLOGY, 医学部, 助手 (50218145)
Project Period (FY) 1992 – 1993
Project Status Completed (Fiscal Year 1993)
Budget Amount *help
¥2,100,000 (Direct Cost: ¥2,100,000)
Fiscal Year 1993: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1992: ¥1,200,000 (Direct Cost: ¥1,200,000)
KeywordsV / Q mismatch / ^<81m> K r gas / ^<99m> T c-MAA / ^<99m> T c-technegas / SPECT / exercise test / lung cancer / COPD / pulmanaty tuberculosis
Research Abstract

The purpose of this study is to evaluate regional V/Q mismatch at rest and during exercise. Our study utilized ^<99m>Tc-macroaggregate albumin to determine distribution of pulmonary blood flow. We used ^<81m> Kr gas to determine resting and exercise ventilation. In 40 cases of various lung deseases ventilation and perfusion images were obtained by simultaneous acquisition from both anterior and posterior surface of patients. With data processing computer GMS-550U distribution of V/Q at each of 128X128 matrix was calculated. Histogram of frequency of V/Q distribution was examined with reference to blood gas analysis and general lung function test. In 15 patients of various lung deseases histogram of frequency of V/Q distribution of SPECT was compared with that of superimposed image from the simultaneous anterior and posterio_2 data acquisition. Correlation between the proportion of V/Q mismatch and A-aDO_2 was examined. V/Q mismatch was made to be within V/Q <0.67 and/or >1.50 in V/Q hi … More stogram. Percentage of V/Q mismatch counts to total counts in histogram was calculated. THere were coefficients of correlation of 0.684(p <0.05) in a terior images, 0.654(p <0.05) in posterior images and 0.696(p <0.05) in superimposed images between percentage of V/Q mismatch in the histogram and A-aDO_2.
The superimposed images showed the highest corelation. No orrelation between general lung function data and A-aDO_2 was observed.
There exisisted significant corelation(r=0.888, p <0.001) between the percentage of V/Q mismatch calculated from SPECT.Dual planner acqusition method relative to the SPECT is useful in showing simple method and shortening of examination time.
The effects of exercise on V/Q distribution in 5 normal sunjects, 13 patients of pulmonary tuberculosis and a patient of COPD were studied. V/Q mismatch in COPD was much more influenced by exercise than in healthy subjects and patients of pulmonary tuberculosis.
For ventilation study intrapulmonary distribution of _<99m> T c-tchnegas was similar to that of _<81m> K r gas, although there existed mild gravitational effect. Less

Report

(3 results)
  • 1993 Annual Research Report   Final Research Report Summary
  • 1992 Annual Research Report
  • Research Products

    (7 results)

All Other

All Publications (7 results)

  • [Publications] 楢林 勇: "安静時並びに運動負荷時におけるSPECTによる換気・血流不均等分布に関する研究" INNERVISION. 8. 27-28 (1993)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Narabayashi I et al.: "Assessment of SPECT ventilation-perfusion imaging in patients with lung cancer." Eur.J.Nucl.Med.12. 329-332 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Kawakami K et al.: "Kinetics and clinical application of ^<99m> T c-technegas" Kakuigaku. 27(7). 72-733 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Matsubara M et al.: "Changes in cardiopulmonary functional reserve after thoracic surgery assessed by treadmill exercise test" Jap J Thoracic Diseases. 29(7). 814-823 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] Ross D J et al.: "Regional distribution of lung perfusion and ventilation at rest and during steady state exercise after unilateral lung transplantation" Chest. 104(1). 130-135 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1993 Final Research Report Summary
  • [Publications] 楢林勇: "安静時並びに運動負荷時におけるSPECTによる換気・血流不均等分布に関する研究" INNERVISION. 8. 27-28 (1993)

    • Related Report
      1993 Annual Research Report
  • [Publications] 楢林 勇: "安静時並びに運動負荷時における換気・血流不均等分布に関する研究" INNERVISION. 8(7). (1993)

    • Related Report
      1992 Annual Research Report

URL: 

Published: 1992-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI