Development of a continuous single tank nitrification-denitrification process

Research Project

Project/Area Number 07455210
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Civil and environmental engineering
Research InstitutionKYOTO UNIVERSITY

Principal Investigator

TSUNO Hiroshi  Kyoto University, Faculty of Eng., Professor, 工学部, 教授 (40026315)

Co-Investigator(Kenkyū-buntansha) YAMADA Harumi  Kyoto University, Faculty of Eng., Instructor, 工学部, 助手 (40089123)
MIYATA Jun  Kyoto University, Graduate school of Eng., Instructor, 工学研究科, 助手 (80273481)
NISHIMURA Fumitake  Kyoto University, Graduate school of Eng., Instructor, 工学研究科, 助手 (60283636)
ONO Yoshiro  Kyoto University, Faculty of Eng., Lecturer, 工学部, 講師 (50152541)
SOMIYA Isao  Kyoto University, Graduate school of Eng., Professor, 工学研究科, 教授 (60025947)
Project Period (FY) 1995 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥5,700,000 (Direct Cost: ¥5,700,000)
Fiscal Year 1997: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1996: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1995: ¥2,900,000 (Direct Cost: ¥2,900,000)
Keywordsdraft-tube type reactor / drafttube / nitrification / denitrification / nitrogen removal / aerobic zone ratio / mathematical model / 硝化 / 脱窒 / 下水処理 / 有機物除去 / 単槽反応器 / コミプラ
Research Abstract

Continuous single tank nitrification-denitrification process was developed to overcome the lssues pointed out in the conventional nitrogen removal processes. Drafttube type reactor was applied to sewage treatment and operational and design parameters of this reactor were examined. Ability of aerobic denitrifier is utilized was also examined.
Empirical equations on velocity of circulating flow and K_La in the draft-tube type reactor are constructed both experimentally and theoretically. Based on the results, continuous sewage treatment was performed. The results showed that 70-75% TN removal efficiency can be obtained in this reactor. It was also found that both aerobic zone ratio and anoxic zone ratio are necessary to be kept more than 0.35 to obtain more than 80% of both nitrification and denitrification ratio. C / N ratio in the influent is necessary to be kept about 3 (mg C / mgN). The ratio of draft tube diameter to reactor diameter (D_1 / D_0) influences TN removal efficiency. In the reactor which has effective depth of 4m, more than 70% TN can be removed only when D_1 / D_0 is 0.19. Analysis of DO decreasing rate in the annulus part shows that the higher effective depth of the reactor is, the easier both aerobic and anoxic zone can be created. Operational and designed parameters for nitrogen removal in the draft tube type reactor were examined extnsively by using the mathematical model.
A selective determination method of the aerobic denitrifier in the mixed liquor is developed with immuno assay. Examination by using the mathematical model shows that the ratio of aerobic denitrifier increased in the mixed liquor by increasing BODMLSS loading rate.

Report

(4 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • 1995 Annual Research Report
  • Research Products

    (25 results)

All Other

All Publications (25 results)

  • [Publications] 津野 洋: "単一槽による下水の硝化・脱窒処理法に関する研究" 日本水環境学会年会講演集. 第29回. 25 (1995)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 津野 洋: "二重管型反応器による下水からの効率的窒素除去に関する研究" 土木学会年次学術講演会講演概要集. 第51回第7部. 76-77 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Effective Nitrogen Removal from Sewage by a Draft-Tube Type Reactor" Proceedings of the Sixth NTU-KU-KAIST Tri-Lateral Seminar/Workshop on Civil Engineering. 6. 377-382 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 津野 洋: "二重管型反応器による下水からの効率的窒素除去法の操作因子に関する研究" 下水道協会誌論文集. Vol.34No.419. 63-75 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 津野 洋: "二重管型反応器における液流動特性とK_Laに関する研究" 下水道研究発表会講演集. 第34回. 632-634 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 津野 洋: "二重管型反応器におけるドラフトチューブ径が窒素除去に及ぼす影響に関する検討" 下水道研究発表会講演集. 第34回. 635-637 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi, Tsuno: "Effect of Draft Tube Dlameter on Nltrogen Removal from Domestic Sewage by a Draft-Tube Type Reactor" Proceedings of the Seventh KAIST-NTU-KU Tri-Lateral Seminar/Workshop on Environmental Engineering. 7. 83-89 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "EFFECT OF DRAFT TUBE DIAMETER ON NITROGEN REMOVAL FROM DOMESTIC SEWAGE IN A DRAFT TUBE TYPE REACTOR" Water Science & Technology. (accepted).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Development of a Sintle Tank Nitrification-Denitrification process for sewage treatment" Proceedings of the 29th annual conference of the Japan society on water environment. Vol.29. 25 (1995)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Effective nitrogen removal from domestic sewage by a draft tube type reactor" Proceedings of the 51th annual conference of the Japan society of civil engineering. 7. 76-77 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Effective Nitrogen Removal from Sewage by a Draft. Tube Type Reactor" Proceedings of the Sixth NTU-KU-KAIST Tri-Lateral Seminar / Workshop on Civil Engineering. Workshop on Civil Engineering. 377-382 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Study on Operational Parameters for Nitrogen Removal from Domestic Sewage in a Draft-Tube Type Reactor" Journal of Japan Sewage Works Association, Research Journal. Vol.34, No.419. 63-75 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Fluid Mechanism and K_La in a draft tube type reactor" Proceedings of the 34th annual conference of the Japan Sewage Works Association. 632-634 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Effect of draft tube diameter on nitrogen removal by a draft tube type reacotr" Proceedings of the 34th annual conference of the Japan Sewage Works Association. 635-637 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi tsuno: "Effect of Draft Tube Diameter on Nitorogen Removal from Domestic Sewage by a Draft-Tube Type Reactor" Proceedings of the Seventh KAIST-NTU-KUTri-Lateral Seminar / Workshop on Environmental Engineering. 83-89 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "EFFECT OF DRAFTTUBE DIAMETER ON NITROGEN REMOVAL FROM DOMESTIC SEWAGE IN A DRAFTTUBE TYPE REACTOR" Water Science & Technology. (accepted).

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Hiroshi Tsuno: "Effective Nitrogen Removal from Sewage by a Draft-Tube Type Reactor" Proceedings of the Sixth NTU-KU-KAIST Tri-Lateral Seminar/Workshop on Civil Engineering. 6. pp.377-382 (1996)

    • Related Report
      1997 Annual Research Report
  • [Publications] 津野 洋: "二重管型反応器による下水からの効率的窒素除去法の操作因子に関する研究" 下水道協会誌論文集. Vol.34 No.419. pp.63-75 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 津野 洋: "二重管型反応器における液流動特性とK_Laに関する研究" 下水道研究発表会講演集. 第34回. pp.632-634 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 津野 洋: "二重管型反応器におけるドラフトチューブ径が窒素除去に及ぼす影響に関する検討" 下水道研究発表会講演集. 第34回. 635-637 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] Hiroshi,Tsuno: "Effect of Draft Tube Diameter on Ntrogen Removal from Domestic Sewage by a Draft-Tube Type Reactor" Proceedings of the Seventh KAIST-NTU-KU Tri-Lateral Seminar/Workshop on Environmental Engineering. 7. 83-89 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] Hiroshi Tsuno: "EFFECT OF DRAFT TUBE DIAMETER ON NITROGEN REMOVAL FROM DOMESTIC SEWAGE IN A DRAFT TUBE TYPE REACTOR" Water Science & Technology. (accepted).

    • Related Report
      1997 Annual Research Report
  • [Publications] 津野洋: "単一槽による下水の硝化・脱窒処理法に関する研究" 日本水環境学会年会講演集. 第29回. pp.25- (1995)

    • Related Report
      1996 Annual Research Report
  • [Publications] 津野洋: "二重管型反応器による下水からの効率的窒素除去に関する研究" 土木学会年次学術講演会講演概要集. 第51回 第7部. pp.76-77 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] Hiroshi Tsuno: "Effective Nitrogen Removal from Sewage by a Draft-Tube Type Reactor" Proceedings of the Sixth NTU-KU-KAIST Tri-Lateral Seminar/Workshop on Civil Engineering. 6. pp.377-382 (1996)

    • Related Report
      1996 Annual Research Report

URL: 

Published: 1995-04-01   Modified: 2016-04-21  