• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of highly sensitive magnetometer

Research Project

Project/Area Number 07554010
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section展開研究
Research Field 固体物性Ⅱ(磁性・金属・低温)
Research InstitutionKeio University

Principal Investigator

MIYAJIMA Hideki  Keio University, Faculty of Science and Technology, Professor, 理工学部, 教授 (70166180)

Co-Investigator(Kenkyū-buntansha) OTANI Yoshichika  Tohoku Uiversity, School of Engineering, Assistance Professor, 工学研究科, 助教授 (60245610)
ONO Teruo  Keio University, Faculty of Science and Technology, Assistance, 理工学部, 助手 (90296749)
Project Period (FY) 1995 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥11,700,000 (Direct Cost: ¥11,700,000)
Fiscal Year 1997: ¥1,400,000 (Direct Cost: ¥1,400,000)
Fiscal Year 1996: ¥2,600,000 (Direct Cost: ¥2,600,000)
Fiscal Year 1995: ¥7,700,000 (Direct Cost: ¥7,700,000)
Keywordsmagnetic moment / magnetometer / mechanical resonance / Small magnetization / 機械共振
Research Abstract

The purpose of this study is to develop and to construct the magnetometer which can detect the magnetic moment so small as 10^<-8> emu over the temperature range from 2K to 1100K under magnetic fields up to 16 kOe in a negative and positive sense. The operational principle of the magnetometer is as follows ; A pair of field gradient coil is fixed on the pole piece of a magnet. A sample is magnetized by static fields variable in magnitude. When the gradient coil generates an alternating magnetic field on the magnetic specimen, an alternating force, proportional to both the magnetic moment of the sample and the strength of the magnitude of the field gradient, exerts on the sample. The sample rod fixed on a plate spring vibrates sympathetically at the mechanical resonance frequency determined by the spring constant and that of the alternating magnetic field, resulting the enhancement of the vibration. The amplitude of the vibration is detected by means of a search coil and, then, is converted to the inductive voltage signal proportional to the magnetic moment. The voltage is detected by using a lock-in amplifier. This new type magnetometer is call as Resonating Sample Magnetometer (RSM). A gas flow type cryostat of liquid He and a furnace with non-inductive heater are also installed in the RSM,and the temperature range from 5K to 1000K is obtained.
At the present stage of March 1998, the performance of the magnetometer is as follows ; The sensitivity : 3.5*10<@D1-7@>D1 emu, the temperature range : 5K-1000K,and the magnetic field range : 0-(]SY.+-。[)16 kOe.
The further improvement of the magnetometer is now carried out so as to realize the high sensitivity of the order of l0^<-8> emu. TOEI Co. Ltd.in Japan will put the commercial base RSM on the market in 1999.

Report

(4 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • 1995 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 能崎 幸雄・宮島 英紀・大谷 義近 他4名: "試料共振型磁力計による微小磁気モーメント測定" 日本応用磁気学会誌. 20. 297-300 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 宮島 英紀・本橋 一成・能崎 幸雄・大谷 義近・増田 宏: "試料共振型高感度磁力計" 日本応用磁気学会誌. 20. 919-920 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Y.Nozaki, H.Miyajima, Y.Otani, H.Masuda, K.Motohashi, T.Manago and K.Runge: "Measurement of Micro Magnetic Moment by Means of Resonating Sample Magnetometry" J.Magn.Soc.Jpn.20. 297-300 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] H.Miyajima, K.Motohashi, Y.Nozaki, Y.Otani, and H.Masuda: "High Sensitive Resonating Sample Magnetometer" J.Magn.Soc.Jpn.20. 919-921 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 宮島英紀,本橋一成,能崎幸雄,大谷義近,増田宏: "試料共振型高感度磁力計" 日本応用磁気学会誌. 20・5. 919-920 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] 能崎幸雄,宮島英紀,大谷義近,増田宏 他3名: "試料共振型磁力計による微小磁気モーメント測定" 日本応用磁気学会誌. 20. 297-300 (1996)

    • Related Report
      1995 Annual Research Report

URL: 

Published: 1995-04-01   Modified: 2020-05-15  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi