Investigation of Radiation-cooled Arc Heater
Project/Area Number |
07555607
|
Research Category |
Grant-in-Aid for Scientific Research (A)
|
Allocation Type | Single-year Grants |
Section | 展開研究 |
Research Field |
Aerospace engineering
|
Research Institution | Kyushu University |
Principal Investigator |
NISHIDA Michio Dept.of Aeronautics & Astronautics, Kyushu Univ.Professor, 工学部, 教授 (10025968)
|
Co-Investigator(Kenkyū-buntansha) |
MATSUMOTO Masashi Research Institute, Ishikawajima-Harima Heavy Industries Co.Ltd.Research Enginee, 技術研究所, 研究員
KIHARA Hisashi Dept.of Aeronautics & Astronautics, Kyushu Univ.Assistant, 工学部, 助手 (60243911)
ASO Shigeru Dept.of Aeronautics & Astronautics, Kyushu Univ.Associate Prof., 工学部, 助教授 (40150495)
|
Project Period (FY) |
1995 – 1997
|
Project Status |
Completed (Fiscal Year 1997)
|
Budget Amount *help |
¥5,200,000 (Direct Cost: ¥5,200,000)
Fiscal Year 1997: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1996: ¥4,400,000 (Direct Cost: ¥4,400,000)
|
Keywords | Arc Heater / High Temperature Gas Dynamics / Arc-heated Wind Tunnel / Ionized Gas |
Research Abstract |
During atmospheric entry, a maximun flight Mach number is over 25 and a very strong shock wave is generated ahead of a nose and wings. Air temperature behind such a strong shock wave becomes over 10,000K and as a result nitrogen and oxygen molecules dissociated and ionized. In addition Nitric oxide is also produced due to the combination of dissociated molecules. An arc-heated wind tunnel can be considered as one of ground test facilities to similate the atmospheric entry conditions, that is to say, a high speed flow of dissociated and ionized air. A conventional arc heater is water-cooled but this water cooling system is considerable complex and sometimes an accident of water occurs. Therfore, in the present study, a radiation-cooled arc heated is proposed instead of a water-cooled arc heater. It is the present aim to develop such a radiation-cooled arc heater and to apply it to studies of high-enthalpy flows needed for the reeentry aerodynamic heating experiments The following items have been done in 1997 : (1) perforamnce test of a arc-heated wind tunnel ・arc current-arc voltage characteristics ・test gas flow rate-arc current characteristics ・arc current-stagnation enthalpy characteristics (2) thermal characterics test ・stagnation heat flux measurements ・estimation of stagnation enthalpy ・estimation of heating efficiency
|