• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A study on the safety of Nursing Performance Audit endotracheal suctioning

Research Project

Project/Area Number 07807216
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Nursing
Research InstitutionKitasato University

Principal Investigator

OKASAKI Sumiko  Kitasato University School of Nursing, Professor, 看護学部, 教授 (30185417)

Co-Investigator(Kenkyū-buntansha) TANAKA Sachiko  Kitasato University School of Nursing Instructor, 看護学部, 助手 (20286371)
HORI Ryoko  Kitasato University School of Nursing Lecturer, 看護学部, 講師 (70199529)
NITTA Natuko  Kitasato University School of Nursing Lecturer, 看護学部, 講師 (10172727)
KIDO Shigeri  Kitasato University School of Nursing, 看護学部, 講師 (20224991)
INOMATA Katsuko  Kitasato University School of Nursing Lecturer, 看護学部, 講師 (20207723)
長谷川 芳子  北里大学, 看護学部, 助手 (80199348)
塚越 フミエ  北里大学, 看護学部, 講師 (70227362)
Project Period (FY) 1995 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥1,900,000 (Direct Cost: ¥1,900,000)
Fiscal Year 1997: ¥300,000 (Direct Cost: ¥300,000)
Fiscal Year 1996: ¥200,000 (Direct Cost: ¥200,000)
Fiscal Year 1995: ¥1,400,000 (Direct Cost: ¥1,400,000)
Keywordsendotracheal suctioning / pressure within suction / Nursing Performance Audit / 喀痰
Research Abstract

Nursing Performance Audit A study on the safety of endotracheal suctioning
The purpose of this study was to reevaluate endotracheal suctioning which is regularly performed under high pressure in the clinical setting, to determine techniques which are safe, effective, and comfortable for the patient.
In a preliminary study, the relationship between pressure within the suction tube and suction volume was examined using simulated sputum. Additionally, quantities of ciliated columnar cells in self-expectorated sputum were estimated in healthy volunteers. As the first part of this investigation, ciliated columnar cells were determined in sputum aspirated at minimum and maximum suction pressures reported in literature. Secondly, rats were subjected to direct suction at high suction pressure. And last, case studies were made on selected cases requiring endotracheal suctioning. The patients were given high pressure suction, and the aspirated phlegm was subjected to microscopical analysis.
Integrating results from the investigation above indicated that it is possible to perform endotracheal suctioning at high pressure without causing mucosal damage to the respiratory tract, provided careful consideration is given to the state of the patient in addition to strict control of the various conditions associated with the procedure itself.

Report

(4 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • 1995 Annual Research Report

Research Products

(3 results)

All Other

All Publications (3 results)

  • [Publications] 長谷川 芳子、岡崎 壽美子、猪又 克子、城戸 滋里、塚越 フミエ: "気管内吸引の安全性に関する研究(第一報)" 日本看護科学会誌. 16(2). 384-385 (1996)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Y,Hasegawa S,Okazaki K,Inomata S,Kido F,Tukakoshi: "A study on the safety of endotracheal suctioning (1)" Journal of Japan Accademy of Nursing Science. 16(2). 384-385 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] 長谷川芳子,岡崎寿美子,猪又克子,城戸滋里,塚哉フミエ: "気管内吸引圧の安全性に関する研究(第一報)" 日本看護科学会誌. 16巻・2号. 384-385 (1996)

    • Related Report
      1996 Annual Research Report

URL: 

Published: 1995-03-31   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi