Development of ESR endoscope detecting free radicals formed in the human body.

Research Project

Project/Area Number 08557126
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Physical pharmacy
Research InstitutionTokyo Metropolitan Institute of Medical Science

Principal Investigator

FUJI Hirotada  Tokyo Metropolitan Institute of Medical Science, Department of Inflammation, Researcher, 炎症研究部門, 研究員 (70209013)

Co-Investigator(Kenkyū-buntansha) ISHIGURO Masaaki  Fuji Photo Optical Co.Ltd., Medical Instrument Department, Researcher, 医用機器部, 研究員
Project Period (FY) 1996 – 1997
Project Status Completed (Fiscal Year 1997)
Budget Amount *help
¥13,000,000 (Direct Cost: ¥13,000,000)
Fiscal Year 1997: ¥6,000,000 (Direct Cost: ¥6,000,000)
Fiscal Year 1996: ¥7,000,000 (Direct Cost: ¥7,000,000)
Keywordsfree radicals / endoscope / L-band ESR / in vivo / oxygen concentration
Research Abstract

We have developed the prototype of the ESR endoscope which is capable of getting information on free radicals generated in the human body. The ESR endoscope is designed as combing ESR spectroscopy and endoscope, thus it can get both the visual information and free radical distribution information. The ESR endoscope is the L-band ESR spectrometer with the single turn loop coil working at the low microwave frequency, 700 MHz to 1,5 GHz, and it can measure the ESR spectrum of any free radical species beside the distribution of the free radicals.
During two years research period, we have focused on solving obstacles when combing the ESR spectroscopy and the endoscope, such as the interference of the CCD video signals with microwave signals. Using the modern technology including newly developed thin coaxial cables, we have mede the ESR endoscope with 2mm diameter signal turn loop coil for ESR probe, which is fit to the common endoscope (3 mm diameter). This prototype can be used as the general endoscope for human.
We also developed the multi-functional loop coil used in the ESR endoscope, which can detect the oxygen concentration and trap free radicals with the short lifetime. To measure the oxygen concentration by the ESR endoscope, the loop coil covered with oxygen permeable materials was developed. Furthermore, to trap the short lifetime free radicals by the loop coil, we also made the loop coil covered with the polymer materials having spin trap goups as side chains.

Report

(3 results)
  • 1997 Annual Research Report   Final Research Report Summary
  • 1996 Annual Research Report
  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] Fujii, et al.: "Determination and characterization of nitric oxide generation in mice by in vivo L-band EPR spectroscopy." Magnetic Resonance in Medicine. 38. 565-568 (1997)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Fujii, H.et al.: "Nitric oxide:prospects and perspectives of in-invo detection by L-band EPR spectroscopy" Bulletin of the Magnetic Resonance. (in press). (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Fujii, H., Koscielniak, J., Berliner, L.J.: "Detection and characterization of nitric oxide generation in mice by in vivo L-band EPR spectrometry." Mag.Reson.Med.37. 565-568 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Fujii, H., Berliner, L.J.: "Nitric oxide : prospects and perspectives of in-vivo detection by L-band EPR spectrometry" Bull.Mag. Reson.(in press). (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1997 Final Research Report Summary
  • [Publications] Fujii,H.et al.: "Determination and characterization of nitric of oxide generation in mice by in vivo L-band EPR spectroscopy." Magnetic Resonance in Medicine. 38. 565-568 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] Fujii,H.et al.: "Nitric oxide:prospects and perspectives of in-invo detection by L-band EPR spectroscopy" Bulletin of the Magnetic Resonance. (in press). (1998)

    • Related Report
      1997 Annual Research Report
  • [Publications] Fujii,H.et al.: "Free-radical Scavenging activities of Natural Carotenoid." Bull.Mag.Reson.18. 55-59 (1996)

    • Related Report
      1996 Annual Research Report
  • [Publications] Fujii,H.et al.: "Determination and characterization of nitric oxide generation in mice by In vivo L-band EPR spectroscopy." Mag.Reson.Med.9(in press). (1997)

    • Related Report
      1996 Annual Research Report
  • [Publications] 藤井 博匡: "バイオサイエンスESR(II)" 廣川書店, 253 (1996)