Development of Implantable cardiac echo probe -Asa Monitor for Cardiac Surgery

Research Project

Project/Area Number 09557110
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Thoracic surgery
Research InstitutionKeio University

Principal Investigator

YOZU Ryohei  Keio University, Dept.of Surg., Assistant Prof., 医学部, 講師 (30129738)

Co-Investigator(Kenkyū-buntansha) HATSUNAKA Toshiyuki  Aloka KK., Research Dept., 技術部・取締役研究職
Project Period (FY) 1997 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥3,000,000 (Direct Cost: ¥3,000,000)
Fiscal Year 1999: ¥1,500,000 (Direct Cost: ¥1,500,000)
Fiscal Year 1998: ¥1,500,000 (Direct Cost: ¥1,500,000)
KeywordsCardiac echo / cardiac function / Cardiac Surgery / Implantble echo-probe / postoperative cardiac monitor / 開心術 / 心臓手術 / 人工心臓 / 人工臓器
Research Abstract

In cardiac surgery, postoperative cardiac function is generally monitored by electocardiography (ECG), by invasive measurements of blood pressure, such as aortic pressure, and by the determination of hemodynamic variables, such as cardiac output, with a Swan-Ganz catheter. In recent years, transesophageal echocardiography has been introduced into clinical use, but, for various reasons, including distress and the difficulty of application in postoperative unconscious patients, it is not a popular method of monitoring, Since 1991, we have been developing a small implantable echocardiography probe. This probe was used in 31 patients with severely reduced left ventricular function who underwent open heart surgery and its clinical utility was well demonstrated. No deaths occurred in this series, This new implantable echocardiography probe allowed postoperative cardiac function to be monitored in real-time, The ejection fraction (EF), the cardiac output, the status of valves after valve replacement and/or valvuloplasty, the left and right ventricular wall motion, the presence of cardiac tamponade, and other variables could be assessed. The echocardiography probe can be positioned at any site at which specific information is desired during surgery. It can be inserted as easily as a pericardial drain tube and is removed in the same manner when no longer necessary. This probe has the potential to be very useful for monitoring patients on assisted circulation after open heart surgery.

Report

(4 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report
  • 1997 Annual Research Report
  • Research Products

    (5 results)

All Other

All Publications (5 results)

  • [Publications] 四津良平: "当科における重症心不全に対する補助人工心臓治療の役割"第2回九州開心術補助手段シンポジウム. (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] "The role of Assisted Circulation for profound cardiac failure"The 2nd Kyushu Assisted Circulation Conference.

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 四津良平: "当科における重症心不全に対する補助人工心臓治療の役割"第2回 九州開心術補助手段シンポジウム. (2000)

    • Related Report
      1999 Annual Research Report
  • [Publications] 四津良平: "心表面・埋め込み型、ディスポーザプルによる心臓手術後モニターの開発と臨床応用、その有用性" 第43回 日本心臓病学会 ビデオシンポジウム. (1995)

    • Related Report
      1998 Annual Research Report
  • [Publications] Ryohei Yozu: "New implantable Echocardiography Probe-Development and" 第68回 American Heart Association(AHA). アナハイム. (1995)

    • Related Report
      1997 Annual Research Report

URL: 