Higher-bit digitization utilized for exposure compensation with digital imaging system for dental office

Research Project

Project/Area Number 09671933
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 病態科学系歯学(含放射線系歯学)
Research InstitutionTOKYO DENTAL COLLEGE

Principal Investigator

HAYAKAWA Yoshihiko  TOKYO DENTAL COLLEGE,DEPT. OF DENTISTRY, LECTURER, 歯学部, 講師 (70164928)

Co-Investigator(Kenkyū-buntansha) MORI Toshimichi  TOKYO DENTAL COLLEGE,DEPT.OF DENTISTRY,ASSISTANT, 歯学部, 助手 (00287187)
SHIBUYA Hitoshi  TOKYO DENTAL COLLEGE,DEPT.OF DENTISTRY,ASSISTANT, 歯学部, 助手 (80246347)
Project Period (FY) 1997 – 1999
Project Status Completed (Fiscal Year 1999)
Budget Amount *help
¥3,000,000 (Direct Cost: ¥3,000,000)
Fiscal Year 1999: ¥600,000 (Direct Cost: ¥600,000)
Fiscal Year 1998: ¥1,000,000 (Direct Cost: ¥1,000,000)
Fiscal Year 1997: ¥1,400,000 (Direct Cost: ¥1,400,000)
KeywordsDigital imaging system / Dental Radiography / Exposure compensation / Quantification / Digital image processing / 歯科X線撮影
Research Abstract

(1) Results from software features of six digital imaging systems for intra-oral radiography. Six digital systems, CDR, PanaDigital(PD), RVG, Sens-A-Ray(SAR), Visualix(VIX) and Digora, were used. Function for the full-mouth survey were evaluated. Software features were classified into three functions, such as image acquisition, image display and image saving. CDR and RVG provided the display disposition to arrange images of the full-mouth survey. Some systems needed several times of clicking prior to acquisition, but no operation for VIX. The period for waiting exposure ranged from 15 sec to an infinity. Automatic exposure compensation was set at PD, RVG and Digora by default. Pixel values were proportional to exposures with CDR, SAR and VIX(linear mode). After the exposure, the captured image was automatically saved with CDR, SAR and Digora. Images were stored in each pateint's directory with CDR, RVG and SAR, Ten-bit storage was employed with PD. The TIF format was adopted by RVG, SA … More R andVIX. The RVG and VIX employed the JPEG. Advantages and drawbacks learned through our experiences were clarified. Software features showed differences. These systems are provided for the use at a dental chair side. They should be designed so that operations are not complicated.
(2) Results from the evaluation of the new storage phosphor-based compted radiography system for dental office. The denOptix CR system is applicable for both intraoral and panoramic radiographic examinations. The DenOptix uses an imaging plate. We examined the new features, different pitches for laser-scanning and the automatic range control (ARC). A jaw phantom and a head phantom were used. Images were captured with the ARC working. Laser-scanning pitch was set at either 150, 300 or 600 dpi. A piece of the Dental X-ray Beam Filter Kit reduced X-ray output to 30%. Even when two pieces were used, the DenOptix was still capable of obtaining intraoral images with acceptable image quality. The DenOptix has also the capability of obtaining panoramic images with a little detriment of noise with the lowest exposure. The ARC worked to compensate both under- and over-exposures and resulted the wide exposure range. The compensation of over-exposures may result in images created with an exposure that gives the patient a higher dose than necessary.
(3) Results from the evaluation of a digital panoramic radiography system. The Dimax is adigital panoramic radiography system which uses a stationary, narrow two-dimensional detector in place of a moving cassette. The purpose of this study is to evaluate software features as an interface to the operator and the image quality related to exposure. Software features were evaluated as four major functions, such as image acquisition, display, storage and transmission. The tissue-equivalent phantom was used to evaluate the exposure reduction. Some excellent software features, for example a combination of hardware and software, ease to operate, care of patient' privacy, were found. The inadequate image quality due to under-exposures was avoidable since the exposure compensation and the gamma conversion worked well. To some extent such compensation worked for over-exposures, but the operator could easily recognize exceeded exposures. Less

Report

(4 results)
  • 1999 Annual Research Report   Final Research Report Summary
  • 1998 Annual Research Report
  • 1997 Annual Research Report
  • Research Products

    (33 results)

All Other

All Publications (33 results)

  • [Publications] 早川吉彦: "Intraoral radiographic storage phosphor image pixel values and signal-to-noise.."Oral Sung Oral Med Oral Pathol Oral Radiol Endod. 86・5. 601-605 (1998)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "Algorithm of pre-processing for displaying digitized images with computed.."Japanese Journal of Medical Physics. 19・Suppl. 141-142 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "An electronic survey of opinions on the compatibility of current X-ray generators.."Dentomaxillofacial Radiology. 28・6. 344-347 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "Rotational panoramic radiography with digital readout : CCD-based sensor coupled.."Radiology. 213Suppl. 500 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "Improvement in digital readout methods applied for intraoral radiography : CMOS-.."Radiology. 213Suppl. 500 (1999)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "Assessing the image quality of a CCD-based digital intraoral radiography system"Bulletin of Tokyo Dental College. 41・1. 9-14 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y., Shibuya,H.,Ota,Y.,Kuroyanagi,K.: "Radiation dosage reduction in general dental practice using digital intraoral radiographic systems."Dental Medium. 6(1). 11-18 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Kuroyanagi,K.,Hayakawa,Y.,Fujimori,H.,Sugiyama,T.: "Distribution of scattered radiation during intraoral radiography with the patient in supine postion."Oral Surgery Oral Medicine Oral Pathology Oral Radiology Endodontics. 85(6). 736-741 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y., Farman,A.G.,Kelly,M.S. and Kuroyanagi,K.: "Intraoral radiographic storage phosphor image mean pixel values and signal-to-noise ratio : Effects of calibration."Oral Surgery Oral Medicine Oral Pathology Oral Radiology Endodontics. 86(5). 601-605 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y., Kuroyanagi,K.,Chen,S.-K.,Farman,A.G.,Welander,U.: "An electronic survey of opinions on the compatibility of current X-ray generators with intra-oral digital X-ray systems."Dentomaxillofacial Radiology. 28(6). 344-347 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y., Kitagawa,H.,Wakoh,M.,Kuroyanagi,K.,Welander,U.: "Assessing the image quality of a CCD-based digital intraoral radiography system : Application of perceptibility curve test"The Bulletin of Tokyo Dental College. 41(1). 9-14 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y.,Kuroyanagi,K.,Oguro,T.: "Evaluation of the new storage phosphor-based computed radiography system for dental office."Radiology. 209, Suppl.(RSNA'98). 586 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y.Mori,T.,Kousuge,Y.,Yamamoto,K.,Kuroyanagi,K.: "Evaluation of the DIMAX digital panoramic radiography system. Hayakawa,Y., Kuroyanagi,K., Ssu-Kuang Chen, Allan,G., Farman, Ulf Welander, Intraoral imaging system and compatibility of existing dental X-ray generators."Program and Abstracts 74 and 119, 1999. (12ィイD1thィエD1 Congress of Dento-Maxillo-Facial Radiology, Osaka, Japan, June, 1999).

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y.,Mori,T.,Shibuya,H.,Kobayashi,N.,Kousuge,Y.,Kuroyanagi,K.: "Rotational panoramic radiography with digital readout : CCD-based sensor coupled with scintillator vs photostimulable phosphor imaging plate."Radiology 1999. 213 Suppl. (RSNA'99). 500 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Hayakawa,Y.,Yamamoto,K.,Wakoh,M.,Fujimori,H.,Kuroyanagi,K.: "Improvement in digital readout methods applied for intraoral radiography : C-MOS-based sensor and storage phosphor imaging plate."Radiology 1999. 213 Suppl. (RSNA'99). 500 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] Yoshihiko Hayakawa,Toshimichi Mori,Yuji Kousuge,Kinya Kuroyanagi: "Ulf Welander. Pre-processing for displaying images with digital and comuted rotational panoramic raadiography Systems."Dentomaxillofacial Radiology. 29 Suppl.1(in press).

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1999 Final Research Report Summary
  • [Publications] 早川吉彦: "Algorithm of pre-processing for displaying digitized images with computed.."Japanese Journal of Medical Physics. 19・Suppl. 141-142 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 早川吉彦: "An electronic survey of opinions on the compatibility of current X-ray generators.."Dentomaxillofacial Radiology. 28・6. 344-347 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 早川吉彦: "Rotational panoramic radiography with digital readout : CCD-based sensor coupled.."Radiology. 213Suppl. 500 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 早川吉彦: "Improvement in digital readout methods applied for intraoral radiography : CMOS-.."Radiology. 213Suppl. 500 (1999)

    • Related Report
      1999 Annual Research Report
  • [Publications] 早川吉彦: "Assessing the image quality of a CCD-based digital intraoral radiography system"Bulletin Tokyo Dental College. 41・1. 9-14 (2000)

    • Related Report
      1999 Annual Research Report
  • [Publications] 早川吉彦: "イメージングプレートを用いる歯科用デジタル画像診断システムDenOptix^<TM>" 映像情報MEDICAL. 30・12. 781-785 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 黒柳錦也: "歯科用デジタルX線画像診断システムの現状と将来" 日本歯科医師会雑誌. 51・8. 746-757 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 早川吉彦: "Intraoral radiographic storage phosphor image mean pixel values and signal-to-noise ratio" Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 86・5. 601-605 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 早川吉彦: "歯科用デジタルX線システム:その概要と今後の展望" the Quintessence. 18・1. 258-260 (1999)

    • Related Report
      1998 Annual Research Report
  • [Publications] 早川吉彦: "Software features of six digital imaging systems for intra-oral radiography" Dentomaxillofacial Radiology. 27・S1. 31 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 早川吉彦: "Evaluation of the new storage phosphor-based computed radiography system for dental office" Radiology. 209Suppl. 586 (1998)

    • Related Report
      1998 Annual Research Report
  • [Publications] 早川吉彦: "口腔内挿入用のCCDセンサー、イメージングプレートのX線透過性" 歯科放射線. 37・4. 316-319 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 澁谷仁志: "歯科用デジタルX線画像診断システムと付加フィルターの利用によって歯科診療所で行った線量軽減" 歯科放射線. 37・4. 320-326 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 早川吉彦: "歯科用デジタルX線画像診断システムにおける画像ファイルフォーマットの汎用性" 歯科放射線. 38・1(掲載予定). (1998)

    • Related Report
      1997 Annual Research Report
  • [Publications] 早川吉彦: "イメージングプレートを利用したデンタルX線イメージングシステムにおける画像処理" 日本医学放射線学会雑誌. 57・12. 828 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 早川吉彦: "イメージングプレートを用いたディジタル口内法X線撮影システムDigoraにおける照射線量補償のための画像処理" 歯科放射線. 37・Suppl.125 (1997)

    • Related Report
      1997 Annual Research Report
  • [Publications] 早川吉彦: "Higher-bit digitization for exposure comensation with digital intraoval imaging system" Dentanamillofacial Radiology. Suppl.34 (1997)

    • Related Report
      1997 Annual Research Report

URL: 

Published: 1997-04-01   Modified: 2016-04-21  