• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Basics and clinical application of nonradioactive xenon-enhanced

Research Project

Project/Area Number 11670892
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionEhime University

Principal Investigator

YASUHARA Yoshifumi  Ehime University, Eaculty of Medicine University Hospital Instructor, 医学部・附属病院, 助手 (90239773)

Co-Investigator(Kenkyū-buntansha) SUGATA Shigenori  Ehime University, Faculty of Medicine University Hospital Instructor, 医学部・附属病院, 助手 (20284416)
TSUDA Takaharu  Ehime University, Faculty of Medicine Instructor, 医学部, 助手 (50207388)
IKEZOE Junpei  Ehime University, Faculty of Medicine Professor, 医学部, 教授 (70115989)
Project Period (FY) 1999 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 2000: ¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1999: ¥1,300,000 (Direct Cost: ¥1,300,000)
KeywordsThoracic CT / Xenon / Lung function / Ventilation / thoracic CT / xenon / lung function / ventilation
Research Abstract

Nonradioactive xenon can be used as a contrast medium for the evaluation of pulmonary ventilation because the CT number of the lung increases proportional to the alveolar xenon gas concentration. In this study, a new scan and reconstruction technique was proposed for detailed mapping of pulmonary ventilation with sequentially acquired xenon-enhanced CT.Scans to measure xenon concentration were performed before xenon inhalation, at the end of 2-min inhalation of 20-percent xenon, then, 1 min after switching the gas to room air. The scans were performed by synchronizing with respiration to obtain the images in the same respiration phase. Digital image processing with nonlinear geometrical warping technique was performed to correct the small mismatch of the images. The kinetics of xenon in the lung was analyzed using principles of indicator dilution theory to create a map of ventilation rate constant. After informed written consent was obtained, xenon-enhanced CT using the above-mentioned technique was applied to healthy volunteers and volunteers with pulmonary emphysema. The averaged ventilation rate constant in the patients with pulmonary emphysema was significantly lower than that in the healthy volunteers. The area with low ventilation rate constant was well correlated with the area of emphysema on CT image. Thus the results suggest that this technique is useful for detailed mapping of impaired ventilation.

Report

(3 results)
  • 2000 Annual Research Report   Final Research Report Summary
  • 1999 Annual Research Report
  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 安原美文 他: "非放射性キセノンCTによる肺換気図"Medical Imaging Technology. Vol.18,No.3. 187-192 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 安原美文 他: "XeCTによる肺換気図"Medical Imaging Technology. Vol.18,No.4. 343-348 (2000)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Yasuhara Y, Ikezoe J, Shimizu K.: "Mapping of pulmonary ventilation with nonradioactive xenon-enhanced CT."Medical Imaging Technology. Vol.18. 187-192 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] Yasuhara Y, Takahashi T, Matsuda T, Ikura H, Ikezoe J, Shimizu K.: "Mapping of pulmonary ventilation with nonradioactive xenon-enhanced CT."Medical Imaging Technology. Vol.18. 343-348 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2000 Final Research Report Summary
  • [Publications] 安原美文 他: "非放射性キセノンCTによる肺換気図"Medical Imaging Technology. Vol.18,No.3. 187-192 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] 安原美文 他: "XeCTによる肺換気図"Medical Imaging Technology. Vol.18,No.4. 343-348 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 1999-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi