Project/Area Number |
12470422
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
補綴理工系歯学
|
Research Institution | The University of Tokushima |
Principal Investigator |
BANDO Eiichi The University of Tokushima, School of Dentistry, Professor, 歯学部, 教授 (00014168)
|
Co-Investigator(Kenkyū-buntansha) |
FUJIMURA Tetsuya Tokushima Bunri University, Faculty of Engineering, Professor, 工学部, 教授 (80219047)
TSURUTA Masahiko Tsurumi University, School of Dental Medicine, Assistant Professor, 歯学部, 講師 (80089458)
KOHNO Shoji Niigata University, Graduate School of Medical and Dental Science, Professor, 大学院・医歯学総合研究科, 教授 (50014098)
TAKEUCHI Hisahiro The University of Tokushima, University Hospital, Assistant Professor, 医学部歯学部附属病院, 講師 (10222093)
NAKANO Masanori The University of Tokushima, School of Dentistry, Associate Professor, 歯学部, 助教授 (30136262)
桑原 洋助 鶴見大学, 歯学部, 教授 (30064348)
|
Project Period (FY) |
2000 – 2003
|
Project Status |
Completed (Fiscal Year 2003)
|
Budget Amount *help |
¥13,800,000 (Direct Cost: ¥13,800,000)
Fiscal Year 2003: ¥4,700,000 (Direct Cost: ¥4,700,000)
Fiscal Year 2002: ¥2,800,000 (Direct Cost: ¥2,800,000)
Fiscal Year 2001: ¥2,700,000 (Direct Cost: ¥2,700,000)
Fiscal Year 2000: ¥3,600,000 (Direct Cost: ¥3,600,000)
|
Keywords | stomatognathic function / database / jaw movement tracking device / jaw movement / six-degree-of-freedom |
Research Abstract |
Although many types of jaw movement analyzing systems have been developed, analyzed results from different systems cannot be compared directly because of differences of base planes or reference points. This kind of luck of interchangeability makes it difficult to accumulate research results and to create the evidence for evaluating stomatognathic function. The purpose of this research was to develop a new stomatognathic function database and establish reference values for evaluating stomatognathic functions In this research, we investigated about information of subjects to register on the database, the standard file format of j aw movements data and analyzing parameters that were independent of measuring systems and could be intercompared among different systems To collect jaw movement data from different systems, we adopted an ASCII sequential format, locus data of jaw movements expressed with three dimensional coordinates (X, Y, Z), those output were could be exported from most of meas
… More
uring systems without any modification of analyzing software. Before registering those data on the database, we processed them with custom software that was developed to convert collected data into standardized formatted jaw movement data. This standard format of jaw movement data made it easy to develop analyzing software that could process jaw movement data from different systems. Then we developed the DBMS (Database Management System) on Microsoft ACCESS2000. At the same time, we also investigated analyzing parameters. It is absolutely essential to establish parameters and reference values that are independent of analyzing systems in order to accumulate research findings. Using these kinds of parameters, measured data from different systems can be evaluated in a uniform manner and used in database to establish reference values of jaw function. Those reference values could be a basic knowledge of the evidence Results of this research were presented in domestic and international meetings and published in many scientific journals Less
|