Project/Area Number |
13555155
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 展開研究 |
Research Field |
Building structures/materials
|
Research Institution | The University of Tokyo |
Principal Investigator |
NOGUCHI Takafumi The University of Tokyo, Graduate School of Engineering, Associate Professor, 大学院・工学系研究科, 助教授 (80208321)
|
Co-Investigator(Kenkyū-buntansha) |
SOU Ken Maeda Kosen Co., Ltd., 開発技術本部, 主任部員
KAGE Tadatsugu Building Research Institute, Department of Production Engineering, Senior Fellow, 建築生産グループ, 上席研究員
KANEMATSU Manabu The University of Tokyo, Graduate School of Engineering, Research Associate, 大学院・工学系研究科, 助手 (00312976)
|
Project Period (FY) |
2001 – 2003
|
Project Status |
Completed (Fiscal Year 2003)
|
Budget Amount *help |
¥13,800,000 (Direct Cost: ¥13,800,000)
Fiscal Year 2003: ¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 2002: ¥1,600,000 (Direct Cost: ¥1,600,000)
Fiscal Year 2001: ¥10,400,000 (Direct Cost: ¥10,400,000)
|
Keywords | speciflc resistance / forced polarization / Non-destructive Inspection Method / Reinforced concrete / Corrosion / Wenner / Dipole-Dipole / 強制分極 / 完全非破壊検査 / 鉄筋腐食 / 比抵抗性 / 完全比破壊検査 |
Research Abstract |
In order to investigate the corrosion state of reinforced concrete structures by non-destructive method, the method of resistivity measurement in the concrete material was adopted. In the present research, it is clear that the resitivity was decreased in case the reinforced bars were under concrete surface measured. Moreover, Dipole-Dipole method is appropriate for the case that electrode array is perpendicular to the direction of bar arrangement. On the other hand, Wenner method is well applied to the parallel direction of bar arrangement against the ekctrode array.
|