Study on the dose distribution measurement precision in the radiotherapy using GAFchromic film
Project/Area Number |
14570859
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | OKAYAMA UNIVERSITY |
Principal Investigator |
AZUMA Yoshiharu Okayama University, Medical School, Associate Professor, 医学部, 助教授 (90212505)
|
Co-Investigator(Kenkyū-buntansha) |
GOTO Sachiko Okayama University, Medical School, Research Associate, 医学部, 助手 (80243517)
NAKAGIRI Yoshitada Okayama University, Medical School, Associate Professor, 医学部, 助教授 (80207745)
|
Project Period (FY) |
2002 – 2003
|
Project Status |
Completed (Fiscal Year 2003)
|
Budget Amount *help |
¥1,900,000 (Direct Cost: ¥1,900,000)
Fiscal Year 2003: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 2002: ¥1,000,000 (Direct Cost: ¥1,000,000)
|
Keywords | Radiotherapy / Dose distribution / Film type dose meter / Gafchromic film / Measurement precision / GAFクロミックフィルム |
Research Abstract |
In the radiotherapy field, a complicated dose distribution must be evaluated and it is required that dose assessment should have the high precision. As the radiometer that performs dose distribution assessment of 2-dimensional one, Radiochromic film is developed and attracts attention. The density ununiformity of the film and the matching with the film and a density-measuring instrument are directly involved in a measurement error directly. Then, while investigating about the ununiformity of the density of the film in this study, the influence, which the optical density before irradiation has on the density after irradiation, was analyzed, and the correction procedure of he influence was considered. First, to dosimetry system, which consists of Laser Densitometer Model 1710 for an x-ray film and Gafchromic film MD-55-2, the check of density measurement precision was performed and the existence of the artifact by the formation, of a 2-dimensional picture of density data was observed in 1-60 Gy. Consequently, in case where the measurement precision in highly detailed pixel level is required, such as performing complicated dose distribution assessment in 3D-CRT or IMRT, it was thought to be necessary to add further the correction process of density ununiformity that is represented by double exposure technique. Furthermore, it turned out that the sample pixel value after irradiation also becomes high as the sample pixel value before irradiation became high. Moreover, since the linear approximation, was possible in the relation between both sample pixel values, the procedure of creating conversion curve of an absorbed dose to a pixel value for every sample pixel value before each irradiation, and correcting the sample pixel value after irradiation was adopted. By this procedure, the measurement result higher than the measurement performed only with the conventional conversion curve of an absorbed dose to a pixel value for precision could be obtained.
|