• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

The Frequency Estimation Method used the Frequency Analysis Type Adaptive Algorithm and Construction of Dynamic Mass Measurement System

Research Project

Project/Area Number 15560368
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Measurement engineering
Research InstitutionOsaka Prefectural College of Technology

Principal Investigator

UMEMOTO Toshitaka  Osaka Prefectural College of Technology, Department of Systems and Control, Associate Professor, システム制御工学科, 助教授 (20280414)

Project Period (FY) 2003 – 2004
Project Status Completed (Fiscal Year 2004)
Budget Amount *help
¥2,700,000 (Direct Cost: ¥2,700,000)
Fiscal Year 2004: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2003: ¥1,400,000 (Direct Cost: ¥1,400,000)
KeywordsLMS Algorithm / Dynamic Mass Measurement / Real Time Processing / ε-Filter / 適応アルゴリズム / 周波数分析
Research Abstract

The necessity of quick and accurate mass measurement is becoming large necessary depending on the development of automations in industries, especially in processing lines. From such a demand, Prof. Ono at Okayama College of Science et al. proposed the mass measurement using transient response obtained from the weighing. In this method, there was a problem that two or more sensors with good accuracy were necessary. However, the vibration frequency and the decrement of transient response obtained from the weighing correspond to the mass of the measuring object. In a word, it is thought that the problem of the sensor can be solved if there is a method of presuming the frequency etc. from the observation data of a short time in high accuracy.
On the other hand, we are studying the spectrum analysis method that uses the LMS algorithm. In this paper, we propose frequency estimation method using the adaptive algorithm by extending this study. In addition, this method shows that it is a method of the effective in the mass measurement in the production line by the experiment.
Dynamic Mass Measurement, Spectra analysis, Complex LMS Algorithm

Report

(3 results)
  • 2004 Annual Research Report   Final Research Report Summary
  • 2003 Annual Research Report
  • Research Products

    (3 results)

All 2004

All Journal Article (3 results)

  • [Journal Article] Dynamic Mass Measurement by the Frequency Estimation Method used the Frequency Analysis Type Adaptive Algorithm2004

    • Author(s)
      Toshitaka UMEMOTO etc
    • Journal Title

      Proc.of SICE Annual Conference in Sapporo August 4-6

      Pages: 198-203

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Dynamic Mass Measurement by the Frequency Estimation Method used the Frequency Analysis Type Adaptive Algorithm2004

    • Author(s)
      Toshitaka UMEMOTO etc.
    • Journal Title

      Proc. of SICE Annual Conference in Sapporo August

      Pages: 198-203

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2004 Final Research Report Summary
  • [Journal Article] Dynamic Mass Measurement by the Frequency Estimation Method used the Frequency Analysis Type Adaptive Algorithm2004

    • Author(s)
      Toshitaka UMEMOTO etc.
    • Journal Title

      Proc. of SICE Annual Conference in Sapporo August 4-6

      Pages: 198-203

    • Related Report
      2004 Annual Research Report

URL: 

Published: 2003-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi