Attempt of 4D-IGRT by Volume Matching Method of 4D-CBCT and Therapy Planning CT
Project/Area Number |
15H04899
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | Hokkaido University |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
梅垣 菊男 北海道大学, 工学研究院, 教授 (40643193)
高尾 聖心 北海道大学, 大学病院, 助教 (10614216)
松浦 妙子 北海道大学, 工学研究院, 准教授 (90590266)
宮本 直樹 北海道大学, 大学病院, 助教 (00552879)
西岡 健太郎 北海道大学, 大学病院, 特任助教 (80463743)
木下 留美子 北海道大学, 大学病院, 助教 (70507582)
加藤 徳雄 北海道大学, 大学病院, 助教 (80572495)
|
Project Period (FY) |
2015-04-01 – 2018-03-31
|
Project Status |
Completed (Fiscal Year 2017)
|
Budget Amount *help |
¥12,220,000 (Direct Cost: ¥9,400,000、Indirect Cost: ¥2,820,000)
Fiscal Year 2017: ¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Fiscal Year 2016: ¥4,420,000 (Direct Cost: ¥3,400,000、Indirect Cost: ¥1,020,000)
Fiscal Year 2015: ¥4,680,000 (Direct Cost: ¥3,600,000、Indirect Cost: ¥1,080,000)
|
Keywords | 放射線治療 / 粒子線治療 / 陽子線治療 / 動体追跡装置 / 四次元放射線治療 / 4D-CT / 4D-CBCT / 医学物理(学) / 医学物理(学) / 4次元CT / CBCT / ゲーティング照射 / コーンビームCT |
Outline of Final Research Achievements |
We conduct research using 2 axis of diagnostic X-ray fluoroscope that consist real-time tumour-tracking (RTRT) system installed in a proton beam treatment gantry. With the use of the system, we conduct a research aimed constructing a 4D-IGRT radiotherapy system that can treat cancer in consideration of spatial and temporal fluctuations and also respiratory movement of tumors. Four-dimensional cone beam CT (4D-CBCT) image is obtained from the fluoroscopic image of the RTRT system. From the 4D-CBCT image group composed of a plurality of respiratory phases, a CT image that represent the same respiratory phase as the CT image used for the treatment plan is selected. We develop an advanced real time image guidance system aiming marker-less 4D-RT using selected CBCT image and its source image.
|
Report
(4 results)
Research Products
(29 results)
-
[Journal Article] Prospective study to evaluate the safety of the world-first spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy system.2018
Author(s)
K. Nishioka, A. Prayongrat, K. Ono, S. Onodera, T. Hashimoto, N. Katoh, T. Inoue, R. Kinoshita, K. Yasuda, T. Mori, R. Onimaru, H. Shirato, and S. Shimizu
-
Journal Title
Journal of Radiation Research
Volume: vol. 59
Issue: suppl_1
Pages: 63-71
DOI
NAID
Related Report
Peer Reviewed / Open Access
-
-
[Journal Article] Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study.2017
Author(s)
Kanehira T, Matsuura T, Takao S, Matsuzaki Y, Fujii Y, Fujii T, Ito YM, Miyamoto N, Inoue T, Katoh N, Shimizu S, Umegaki K, Shirato H
-
Journal Title
Int J Radiat Oncol Biol Phys.
Volume: 97(1)
Issue: 1
Pages: 173-181
DOI
Related Report
Peer Reviewed / Open Access
-
-
[Journal Article] NTCP modeling analysis of acute hematologic toxicity in whole pelvic radiation therapy for gynecologic malignancies - A dosimetric comparison of IMRT and spot-scanning proton therapy (SSPT).2016
Author(s)
Yoshimura T, Kinoshita R, Onodera S, Toramatsu C, Suzuki R, Ito YM, Takao S, Matsuura T, Matsuzaki Y, Umegaki K, Shirato H, Shimizu S
-
Journal Title
Phys Med.
Volume: 32(9)
Issue: 9
Pages: 1098-1102
DOI
NAID
Related Report
Peer Reviewed / Open Access / Acknowledgement Compliant
-
[Journal Article] Optimization and evaluation of multiple gating beam delivery in a synchrotron-based proton beam scanning system using a real-time imaging technique.2016
Author(s)
Yamada T, Miyamoto N, Matsuura T, Takao S, Fujii Y, Matsuzaki Y, Koyano H, Umezawa M, Nihongi H, Shimizu S, Shirato H, Umegaki K
-
Journal Title
Phys Med.
Volume: 32(7)
Issue: 7
Pages: 932-937
DOI
NAID
Related Report
Peer Reviewed / Open Access
-
-
-
-
-
-
-
[Presentation] Development of a System for Evaluating the Actual Dose Distribution in Respiratory-Gated Spot-Scanning Proton Therapy Using Real-Time Image Guidance2017
Author(s)
T. Matsuura, S. Hirayama, H. Koyano, S. Takao, T. Fujii, T. Yamada, Y.Fujii, H. Nihongi, S. Shimizu, K. Umegaki, H. Shirato
Organizer
2017 AAPM 59th Annual Meeting
Related Report
Int'l Joint Research
-
[Presentation] A prospective study to evaluate the safety of the world-first spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy system2017
Author(s)
Kentaro Nishioka, Shinichi Shimizu, Koichi Yasuda, Kota Ono, Takayuki Hashimoto, Norio Katoh, Tetsuya Inoue, Kazuhiko Tsuchiya, Rikiya Onimaru, Hiroki Shirato
Organizer
56th Annual Conference of the Particle Therapy Co-Operative Group
Related Report
Int'l Joint Research
-
[Presentation] An Organ Motion and Acute Toxicity Study of Image-guided Spot-Scanning Proton Beam Therapy with An Internal Fiducial Marker for Pancreatic Cancers2017
Author(s)
Uchinami Y, Katoh N, Abo D, Harada K, Nishikawa Y, Inoue T, Hashimoto T, Onimaru R, Miyamoto N, Sakuhara Y, Shimizu S, Shirato H
Organizer
2017 ASTRO 59th Annual Meeting
Related Report
Int'l Joint Research
-
-
-
-
[Presentation] Treatment Time and Dose Rate Analysis for Respiratory Moving Liver Tumor Using Real-time-image Gated Spot Scanning Proton Beam Therapy System2016
Author(s)
Shimizu S, Katoh N, Takao S, Matsuura T, Miyamoto N, Hashimoto T, Nishioka K, Yoshimura T, Umegaki K, Shirato H
Organizer
ASTRO 2016 Annual Meeting
Place of Presentation
Boston, USA
Year and Date
2016-09-25
Related Report
Int'l Joint Research
-
-
[Presentation] Stereotactic Body Radiation Therapy Using a Real-time Tumor-Tracking Radiation Therapy System for Hepatocellular Carcinomas2016
Author(s)
Uchinami Y, Katoh N, Abo D, Harada K, Inoue T, Taguchi H, Onimaru R, Shimizu S, Sakuhara Y, Ogawa K, Kamiyama T, Shirato H
Organizer
ASTRO 2016 Annual Meeting
Place of Presentation
Boston, USA
Year and Date
2016-09-25
Related Report
Int'l Joint Research
-
-
-
[Presentation] Initial clinical experience of spot-scanning proton beam therapy using real-time-image gated proton-beam therapy system2015
Author(s)
Shimizu S, Katoh N, Kentaro N, Hashimoto T, Inoue T, Matsuura T, Takao S, Matsuzaki Y,Fujii Y, Tamura M, Onimaru R, Umegaki K, Shirato H
Organizer
4D Treatment Planning Workshop 2015
Place of Presentation
Dresden(Germany)
Year and Date
2015-11-26
Related Report
Int'l Joint Research
-
-
[Presentation] Treatment of respiratory moving liver tumor using gated spot scanning proton beam therapy system with real-time tumor-tracking function2015
Author(s)
Shimizu S, Katoh N, Takao S, Matsuura T, Miyamoto N, Hashimoto T, Nishioka K, Yoshimura T, Matsuzaki Y, Kinoshita R, Nishikawa Y, Onimaru R, Umegaki K, Shirato H
Organizer
57th Annual Meeting of American Society of Therapeutic Radiology and Oncology
Place of Presentation
San Antonio(USA)
Year and Date
2015-10-18
Related Report
Int'l Joint Research
-
-
-