Project/Area Number |
16560175
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Thermal engineering
|
Research Institution | Tokyo Institute of Technology |
Principal Investigator |
NAGASAKI Takao Tokyo Institute of Technology, Department of Energy Sciences, Associate Professor, 大学院・総合理工学研究科, 助教授 (30155923)
|
Project Period (FY) |
2004 – 2005
|
Project Status |
Completed (Fiscal Year 2005)
|
Budget Amount *help |
¥3,100,000 (Direct Cost: ¥3,100,000)
Fiscal Year 2005: ¥1,300,000 (Direct Cost: ¥1,300,000)
Fiscal Year 2004: ¥1,800,000 (Direct Cost: ¥1,800,000)
|
Keywords | heat pump / absorption / enhancement |
Research Abstract |
In order to improve the performance of absorption heat pump for the use of low temperature waste heat, a new enhancement method of water vapor absorption into LiBr/water solution was proposed. A copper plate is attached to the bottom of horizontal heat transfer tube. The plate enables additional vapor absorption when the absorbent liquid film flows down along the plate. The enhancement effect of the proposed method was investigated experimentally, and it was found that the absorption is enhanced by the plate in the region of relatively small liquid flow rate. In addition, the proposed method was applied to regenerator, and nearly the same performance was obtained as that of absorber. Based on the experimental data of absorption rate, the performance of two-stage absorption heat pump was analyzed, and the optimum operating condition was clarified.
|