• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of fluorescent gel dosimeter

Research Project

Project/Area Number 17K07013
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Nuclear engineering
Research InstitutionKitasato University

Principal Investigator

Maeyama Takuya  北里大学, 理学部, 助教 (70612125)

Co-Investigator(Kenkyū-buntansha) 余語 克紀  名古屋大学, 医学系研究科(保健), 助教 (30424823)
Project Period (FY) 2017-04-01 – 2021-03-31
Project Status Completed (Fiscal Year 2020)
Budget Amount *help
¥4,810,000 (Direct Cost: ¥3,700,000、Indirect Cost: ¥1,110,000)
Fiscal Year 2019: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2018: ¥2,600,000 (Direct Cost: ¥2,000,000、Indirect Cost: ¥600,000)
Fiscal Year 2017: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Keywords蛍光ゲル線量計 / ゲル線量計 / ナノクレイ / 蛍光 / 放射線化学 / 3次元線量計 / 放射線治療 / 三次元線量分布 / 化学線量計 / 蛍光プローブ / 水溶液線量計 / イオンビーム / 放射線
Outline of Final Research Achievements

In the radiation chemistry, developing chemical dosimeters has been promoted, especially those that are prepared by gelling aqueous chemical dosimeters that have been studied for their use in radiotherapy. In the radiotherapy, it is necessary to concentrate the dose on cancer cells only and to reduce its exposure to the surrounding healthy tissues. Therefore, a complicated dose distribution has made with developing the irradiation method. Gel dosimeters are expected to be QA tools for complex dose distributions for only the tissue-equivalent 3D dosimetry, since the gels are made with water, which is the main component of the human body. The 3D dose distribution is read by imaging the irradiated gel with a 3D scanner, such as either magnetic resonance, optical computed tomography. In this research, we have developed a nanocomposite fluorescent gel dosimeter that enables readout by the fluorometry, which is more sensitive than absorption method in principle.

Academic Significance and Societal Importance of the Research Achievements

放射線治療の高精度化に伴い、複雑な線量分布を一回の照射で測定できる線量計の開発が求められている。本研究では、これまでにない新しい原理にもとづくゲル線量計の開発に成功した。すなわち、ナノクレイ添加蛍光ゲル線量計である。蛍光法は吸光度法に比べ、原理的に1000倍の高い感度での評価が可能であり、本研究成果によって、今後さらなる化学線量測定法の発展が期待される。

Report

(5 results)
  • 2020 Annual Research Report   Final Research Report ( PDF )
  • 2019 Research-status Report
  • 2018 Research-status Report
  • 2017 Research-status Report
  • Research Products

    (36 results)

All 2020 2019 2018 2017

All Journal Article (10 results) (of which Peer Reviewed: 8 results,  Open Access: 2 results,  Acknowledgement Compliant: 1 results) Presentation (23 results) (of which Int'l Joint Research: 7 results,  Invited: 2 results) Patent(Industrial Property Rights) (3 results)

  • [Journal Article] Verification of dose distribution in high-dose-rate brachytherapy using a nanoclay-based radio-fluorogenic gel dosimeter2020

    • Author(s)
      Watanabe Yusuke、Maeyama Takuya、Mochizuki Anri、Mizukami Shinya、Hayashi Shin-ichiro、Terazaki Tsuyoshi、Muraishi Hiroshi、Takei Hideyuki、Gomi Tsutomu、Shimono Tetsunori
    • Journal Title

      Physics in Medicine & Biology

      Volume: 65 Issue: 17 Pages: 175008-175008

    • DOI

      10.1088/1361-6560/ab98d2

    • Related Report
      2020 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Sensitivity enhancement of DHR123 radio-fluorogenic nano clay gel dosimeter by incorporating surfactants and halogenides2020

    • Author(s)
      Mochizuki A, Maeyama T, Watanabe Y, Mizukami S.
    • Journal Title

      RSC Advances

      Volume: 10 Issue: 48 Pages: 28798-28798

    • DOI

      10.1039/d0ra02717k

    • Related Report
      2020 Annual Research Report
    • Peer Reviewed
  • [Journal Article] 3.2.5 Development of LET-independent Gel Dosimeter—MRI (magnetic resonance imaging)-based Fricke Gel Dosimeter—2019

    • Author(s)
      前山 拓哉
    • Journal Title

      RADIOISOTOPES

      Volume: 68 Issue: 4 Pages: 267-276

    • DOI

      10.3769/radioisotopes.68.267

    • NAID

      130007632615

    • ISSN
      0033-8303, 1884-4111
    • Year and Date
      2019-04-15
    • Related Report
      2018 Research-status Report
    • Open Access
  • [Journal Article] Radiation induced degradation of rhodamine 6G and 7-Diethylamino-4-methylcoumarin in nano-clay gel for use in dosimeter2019

    • Author(s)
      T. Maeyama, A. Mochizuki, T. Takanashi
    • Journal Title

      Journal of Physics: Conference Series

      Volume: 1305 Issue: 1 Pages: 12045-12045

    • DOI

      10.1088/1742-6596/1305/1/012045

    • Related Report
      2019 Research-status Report
    • Peer Reviewed / Open Access
  • [Journal Article] Dose-rate-independent and diffusion-free nanoclay-based radio-fluorogenic gel dosimeter2019

    • Author(s)
      Maeyama T, Kato A, Mochizuki A, Sato N, Watanabe Y, Mizukami S
    • Journal Title

      Sens Actuators A-Phys

      Volume: 298 Pages: 111435-111435

    • DOI

      10.1016/j.sna.2019.06.015

    • Related Report
      2019 Research-status Report
    • Peer Reviewed
  • [Journal Article] Dose distribution verification in high-dose-rate brachytherapy using a highly sensitive normoxic N-vinylpyrrolidone polymer gel dosimeter2019

    • Author(s)
      Watanabe Yusuke、Mizukami Shinya、Eguchi Kou、Maeyama Takuya、Hayashi Shin-ichiro、Muraishi Hiroshi、Terazaki Tsuyoshi、Gomi Tsutomu
    • Journal Title

      Physica Medica

      Volume: 57 Pages: 72-79

    • DOI

      10.1016/j.ejmp.2018.12.007

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Nanoclay gel-based radio-fluorogenic gel dosimeters using various fluorescence probes2018

    • Author(s)
      Maeyama Takuya、Hase Shinnosuke
    • Journal Title

      Radiation Physics and Chemistry

      Volume: 151 Pages: 42-46

    • DOI

      10.1016/j.radphyschem.2018.05.009

    • Related Report
      2018 Research-status Report
    • Peer Reviewed
  • [Journal Article] Polymer gel dosimeter with AQUAJOINT as hydrogel matrix2018

    • Author(s)
      Maeyama Takuya、Ishida Yasuhiro、Kudo Yoshihiro、Fukasaku Kazuaki、Ishikawa Kenichi L.、Fukunishi Nobuhisa
    • Journal Title

      Radiation Physics and Chemistry

      Volume: 146 Pages: 121-125

    • DOI

      10.1016/j.radphyschem.2018.01.014

    • Related Report
      2017 Research-status Report
    • Peer Reviewed
  • [Journal Article] Organic-Gelatin-Free Nanocomposite Fricke Gel Dosimeter.2017

    • Author(s)
      T. Maeyama, N. Fukunishi, K. L. Ishikawa, K. Fukasaku, S. Fukuda
    • Journal Title

      The Journal of Physical Chemistry B

      Volume: 121 Issue: 16 Pages: 4238-4246

    • DOI

      10.1021/acs.jpcb.6b11936

    • Related Report
      2017 Research-status Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Fricke Gel Dosimeters2017

    • Author(s)
      前山 拓哉
    • Journal Title

      Japanese Journal of Medical Physics (Igakubutsuri)

      Volume: 37 Issue: 2 Pages: 99-106

    • DOI

      10.11323/jjmp.37.2_99

    • NAID

      130006943057

    • ISSN
      1345-5354, 2186-9634
    • Related Report
      2017 Research-status Report
  • [Presentation] Preliminary investigation of nanoclay gel-based fluorescent gel dosimeters under carbon ion beam2020

    • Author(s)
      T. Maeyama, A. Mochizuki, N. Fukunishi, K. L. Ishikawa
    • Organizer
      8th Asia Pacific Symposium on Radiation Chemistry (APSRC2020)
    • Related Report
      2020 Annual Research Report
    • Int'l Joint Research
  • [Presentation] 高線量率小線源治療における蛍光ゲル線量計を用いた線量分布測定2020

    • Author(s)
      井上 幹太, 渡邉 祐介, 前山 拓哉, 水上 慎也, 寺崎 剛史, 林 慎一郎, 村石 浩, 五味 勉, 下野 哲範
    • Organizer
      第81回応用物理学会秋季学術講演会
    • Related Report
      2020 Annual Research Report
  • [Presentation] 3D蛍光断層スキャナ開発の初期検討2020

    • Author(s)
      井上幹太, 渡邉祐介, 前山拓哉, 吉田和輝, 村石浩, 水上慎也, 大内結希乃, 金子睦美, 下野哲範
    • Organizer
      第9回3次元ゲル線量計研究会
    • Related Report
      2020 Annual Research Report
  • [Presentation] 蛍光ゲル線量計の光安定性の評価と新規分散剤の検討2020

    • Author(s)
      吉田 和輝, 前山拓哉, 渡邉祐介, 水上慎也
    • Organizer
      第9回3次元ゲル線量計研究会
    • Related Report
      2020 Annual Research Report
  • [Presentation] ゲル線量計を用いた医療放射線の線量分布測定研究2020

    • Author(s)
      前山拓哉
    • Organizer
      医療放射線技術研究会「様々な時間的・空間的スケールの量子線計測技術」
    • Related Report
      2019 Research-status Report
    • Invited
  • [Presentation] 重粒子線治療用蛍光ゲル線量計の開発2019

    • Author(s)
      望月杏莉 前山拓哉 福西暢尚 石川顕一
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] 高線量率小線源治療における蛍光ゲル線量計による線量分布測定の初期検討2019

    • Author(s)
      渡邉祐介 前山拓哉 望月杏莉 寺崎剛史 水上慎也 清水大地 志賀伊吹 武田小瑚 森瑞喜
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] 高LET放射線照射時のナノコンポジットフリッケゲル線量計の基礎特性2019

    • Author(s)
      前山拓哉 望月杏莉 磯村りお 渡邉祐介 水上慎也 福西暢尚 石川顕一 福田茂一
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] 192Ir線源停留位置の精度管理におけるポリマーゲル線量計の有用性2019

    • Author(s)
      寺崎剛史 渡邉祐介 水上慎也 前山拓哉 橘英伸 林慎一郎 板野正信 上原隆三 村石浩 五味勉 下野哲範
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] 包括的なゲルドシメトリ体制の確立2019

    • Author(s)
      橘英伸 橘理絵 渡邉祐介 前山拓哉 水上慎也 三浦季子 上間亜紗果 加藤由佳 石垣絢子 長田燎平 飯嶋亮平 中村彩花 白石貴博 遠山尚紀 小玉卓史 幡野和男
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] 高線量率小線源治療におけるDeformable gel dosimetryの初期検討2019

    • Author(s)
      笠井勇作 渡邉祐介 水上慎也 前山拓哉 寺崎剛史 林慎一郎
    • Organizer
      第8回3Dゲル線量計研究会
    • Related Report
      2019 Research-status Report
  • [Presentation] ジヒドロローダミン 6G と123 蛍光ゲル線量計の増感剤・界面活性剤の影響2019

    • Author(s)
      望月杏莉 前山拓哉 渡邉祐介 水上慎也
    • Organizer
      第62回放射線化学討論会
    • Related Report
      2019 Research-status Report
  • [Presentation] NC-FG 線量計へのラジカル捕捉剤の添加効果2019

    • Author(s)
      前山拓哉 望月杏莉 福西暢尚 石川顕一 福田茂一
    • Organizer
      第62回放射線化学討論会
    • Related Report
      2019 Research-status Report
  • [Presentation] Radiological properties of coumarin derivative fluorescent gel dosimeter2019

    • Author(s)
      Anri Mochizuki Takuya Maeyama
    • Organizer
      The 19th International Conference on Solid State Dosimetry (SSD19)
    • Related Report
      2019 Research-status Report
    • Int'l Joint Research
  • [Presentation] Fluorescent gel dosimeter using 7-diethylamino-4-methylcoumarin: Effects of radical scavengers on radio-degradation yield2019

    • Author(s)
      Anri Mochizuki Takuya Maeyama
    • Organizer
      16th International Congress of Radiation Research (ICRR2019)
    • Related Report
      2019 Research-status Report
    • Int'l Joint Research
  • [Presentation] Nanoclay gel-based radio-fluorogenic gel dosimeters using Dihydrorhodamine 1232019

    • Author(s)
      Takuya Maeyama Ayumi Kato Anri Mochizuki Yusuke Watanabe Shinya Mizukami
    • Organizer
      16th International Congress of Radiation Research (ICRR2019)
    • Related Report
      2019 Research-status Report
    • Int'l Joint Research
  • [Presentation] A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter2019

    • Author(s)
      K.Eguchi Y.Watanabe S.Mizukami T.Maeyama S.Hayashi T.Gomi
    • Organizer
      American Association of Physicists in Medicine 2018 Annual Meeting (AAPM 2018 )
    • Related Report
      2019 Research-status Report
    • Int'l Joint Research
  • [Presentation] Radiation induced degradation of rhodamine 6G and 7-Diethylamino-4-methylcoumarin in nano-clay gel for use in dosimeter2018

    • Author(s)
      T. Maeyama A. Mochizuki T. Takanashi
    • Organizer
      10th International Conference on 3D and Advanced Dosimetry
    • Related Report
      2018 Research-status Report
    • Int'l Joint Research
  • [Presentation] 蛍光ゲル線量計の2D解析手法の初期検討2018

    • Author(s)
      前山拓哉 加藤歩実 佐藤直樹 望月杏莉
    • Organizer
      第7回3Dゲル線量計研究会
    • Related Report
      2018 Research-status Report
  • [Presentation] 望月杏莉 前山拓哉2018

    • Author(s)
      クマリン誘導体蛍光ゲル線量計~ラジカル捕捉剤の影響~
    • Organizer
      第7回3Dゲル線量計研究会
    • Related Report
      2018 Research-status Report
  • [Presentation] MRI-based Gel Dosimeter for Heavy ion Beam Cancer Therapy2018

    • Author(s)
      T. Maeyama
    • Organizer
      International Congress on Pure & Applied Chemistry (ICPAC) 2018
    • Related Report
      2017 Research-status Report
    • Int'l Joint Research / Invited
  • [Presentation] 蛍光プローブを用いたゲル線量計の開発2017

    • Author(s)
      前山拓哉, 長谷真之介
    • Organizer
      第6回3Dゲル線量計研究会
    • Related Report
      2017 Research-status Report
  • [Presentation] 蛍光プローブを用いた放射線線量測定ゲルの開発2017

    • Author(s)
      前山拓哉
    • Organizer
      第10回北里化学シンポジウム(AKPS2017)
    • Related Report
      2017 Research-status Report
  • [Patent(Industrial Property Rights)] 放射線線量測定用組成物及びその製造方法、並びに放射線線量計2019

    • Inventor(s)
      前山拓哉 , 福西暢尚 , 石川顕一
    • Industrial Property Rights Holder
      学校法人北里研究所, 国立研究開発法人理化学研究所
    • Industrial Property Rights Type
      特許
    • Filing Date
      2019
    • Acquisition Date
      2021
    • Related Report
      2020 Annual Research Report
  • [Patent(Industrial Property Rights)] 放射線線量測定用組成物及びその製造方法、並びに放射線線量計2019

    • Inventor(s)
      前山拓哉 福西暢尚 石川顕一
    • Industrial Property Rights Holder
      学校法人北里研究所, 国立研究開発法人理化学研究所
    • Industrial Property Rights Type
      特許
    • Industrial Property Number
      2019-157190
    • Filing Date
      2019
    • Related Report
      2019 Research-status Report
  • [Patent(Industrial Property Rights)] 放射線線量測定ゾル又はゲル、及びそれを放射線線量の計測材料として備える放射線線量計2017

    • Inventor(s)
      前山拓哉、櫻葉汀ダニエルアントニオ、 高梨宇宙
    • Industrial Property Rights Holder
      前山拓哉、櫻葉汀ダニエルアントニオ、 高梨宇宙
    • Industrial Property Rights Type
      特許
    • Industrial Property Number
      2017-193001
    • Filing Date
      2017
    • Related Report
      2017 Research-status Report

URL: 

Published: 2017-04-28   Modified: 2022-01-27  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi