Ultra-high resolution SPECT with a semiconductor detector and a diverging collimator

Research Project

Project/Area Number 18390337
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionHosei University

Principal Investigator

OGAWA Koichi  Hosei University, Faculty of Engineering, Professor (00158817)

Project Period (FY) 2006 – 2007
Project Status Completed (Fiscal Year 2007)
Budget Amount *help
¥16,550,000 (Direct Cost: ¥15,500,000、Indirect Cost: ¥1,050,000)
Fiscal Year 2007: ¥4,550,000 (Direct Cost: ¥3,500,000、Indirect Cost: ¥1,050,000)
Fiscal Year 2006: ¥12,000,000 (Direct Cost: ¥12,000,000)
Keywordssemiconductor detector / single photon emission CT / diverging collimator / ultra-high resolution imaging / Monte Carlo simulation / gamma ray
Research Abstract

The development of semiconductor detectors such as CdTe, which works at room temperature, has facilitated the development of a new SPECT system. These semiconductor detectors have a high energy resolution. Moreover, they are used as pixellated detectors, and so the intrinsic resolution can be equal to the size of the pixel used for measurement. The detector pixel is as small as 0.5mm, and so the spatial resolution of a reconstructed SPECT image can be less than 3mm FWHM. To clarify the feasibility of an ultra-high resolution SPECT system, we conducted some simulations and evaluated the quality of images. In these simulations we used a diverging collimator to enlarge the field of view of the detector and compared the quality of the reconstructed images of a pixellated SPECT system with a conventional SPECT system with a scintillation detector and parallel-hole collimator under the same sensitivity and reduced sensitivity. The results showed that the improvement of the spatial resolution in the pixellated semiconductor detector yielded high quality images even under the low sensitivity condition due to the small size of the pixels. With the above results we built a prototype semiconductor SPECT system with a diverging collimator. In this system we made the diverging collimator by using several hundreds of thin tungsten plates. With this proposed ultra-high resolution system we established the reconstruction of rod phantoms(hot rod phantom and cold rod phantom) with the spatial resolution of 1.0mm for the hot rods and 1.6mm for the cold rods. The obtained results with the simulation and experiment showed that the ultra-high resolution SPECT system was available with the semiconductor detector and a parallel-hole collimator or a diverging collimator with holes of a small size.

Report

(3 results)
  • 2007 Annual Research Report   Final Research Report Summary
  • 2006 Annual Research Report
  • Research Products

    (29 results)

All 2007 2006

All Journal Article (10 results) (of which Peer Reviewed: 1 results) Presentation (19 results)

  • [Journal Article] 核医学画像の将来2007

    • Author(s)
      尾川 浩一
    • Journal Title

      臨床放射線 52

      Pages: 1114-1120

    • NAID

      10024455704

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Annual Research Report 2007 Final Research Report Summary
  • [Journal Article] Nuclear medicine images in future2007

    • Author(s)
      Koichi Ogawa
    • Journal Title

      Japanese Journal of Clinical Radiology Vol.52, No.9

      Pages: 1114-1120

    • NAID

      40015637522

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] Simulation Study on an Ultra-High Resolution SPECT with CdTe Detectors2006

    • Author(s)
      Koichi Ogawa
    • Journal Title

      Conference Record on IEEE Nuclear Science Symposium and Medical Imaging Conference

      Pages: 2421-2425

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
    • Peer Reviewed
  • [Journal Article] Simulation Study on an Ultra-High Resolution SPECT with CdTe Detectors2006

    • Author(s)
      Koichi Ogawa
    • Journal Title

      Conference record on IEEE Nuclear Science Symposium and Medical Imaging Coference

      Pages: 2421-2425

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Journal Article] Simulation Study on an Ultra-High Resolution SPECT with CdTe Detectors2006

    • Author(s)
      Koichi Ogawa
    • Journal Title

      IEEE Nuclear Symposium and Medical Imaging Conference CD-ROM出版

    • Related Report
      2006 Annual Research Report
  • [Journal Article] 半導体検出器を用いたSPECT2006

    • Author(s)
      小宮山英明
    • Journal Title

      医学物理 26(2)

      Pages: 139-140

    • Related Report
      2006 Annual Research Report
  • [Journal Article] 超高分解能SPECTに関するモンテカルロシミュレーション2006

    • Author(s)
      村石雅明
    • Journal Title

      医学物理 26(3)

      Pages: 161-162

    • Related Report
      2006 Annual Research Report
  • [Journal Article] ピクセル型検出器を用いた超高分解能イメージング2006

    • Author(s)
      尾川浩一
    • Journal Title

      核医学 43(3)

      Pages: 204-204

    • Related Report
      2006 Annual Research Report
  • [Journal Article] ピクセル型検出器とコリメータのアライメントの関係2006

    • Author(s)
      尾川浩一
    • Journal Title

      核医学 43(3)

      Pages: 183-183

    • Related Report
      2006 Annual Research Report
  • [Journal Article] Relationship between collimator holes and pixels in gamma-ray pixellized semiconductor detector2006

    • Author(s)
      Koichi Ogawa
    • Journal Title

      International conference on imaging techniques in subatomic physics, astrophysics, medicine, biology and industry

      Pages: 85-85

    • Related Report
      2006 Annual Research Report
  • [Presentation] CdTeピクセル型検出器を用いた超高分解能ガンマ線イメージング2007

    • Author(s)
      尾川 浩一
    • Organizer
      第47回日本核医学会学術総会
    • Place of Presentation
      仙台市
    • Year and Date
      2007-11-04
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Annual Research Report 2007 Final Research Report Summary
  • [Presentation] Ultra-high resolution gamma ray imaging with a CdTe pixellated semiconductor detector2007

    • Author(s)
      Koichi Ogawa
    • Organizer
      The 47th Annual Meeting of the Japanese Society of Nuclear Medicine
    • Place of Presentation
      Sendai
    • Year and Date
      2007-11-04
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] 超高分解能SPECTの開発2007

    • Author(s)
      村石 雅明
    • Organizer
      第94回日本医学物理学会学術大会
    • Place of Presentation
      新潟市
    • Year and Date
      2007-09-28
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Annual Research Report 2007 Final Research Report Summary
  • [Presentation] Development of an ultra-high resolution SPECT2007

    • Author(s)
      Masaaki Muraishi
    • Organizer
      The 94th Scientific Meeting of Japan Society of Medical Physics
    • Place of Presentation
      Niigata
    • Year and Date
      2007-09-28
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Ultra-High Resolution SPECT with CdTe Detectors2007

    • Author(s)
      Koichi Ogawa
    • Organizer
      The 10th EFOMP Congress (First European Conference on Medical Physics)
    • Place of Presentation
      Pisa,Italy
    • Year and Date
      2007-09-21
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Ultra-high resolution SPECT with CdTe detectors2007

    • Author(s)
      Koichi Ogawa
    • Organizer
      The 10th EFOMP Congress[First European Conference on Medical Physics]
    • Place of Presentation
      Pisa, Italy
    • Year and Date
      2007-09-21
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Ultra-High Resolution SPECT with CdTe Detectors2007

    • Author(s)
      Koiohi Ogawa
    • Organizer
      The 10th EFOMP Congress(First European Conference on Medical Physics)
    • Place of Presentation
      Pisa(ltaly)
    • Year and Date
      2007-09-21
    • Related Report
      2007 Annual Research Report
  • [Presentation] CdTe検出器を用いた超高分解能ガンマカメラシステムの開発2007

    • Author(s)
      大村 尚加
    • Organizer
      第26回日本医用画像工学会大会
    • Place of Presentation
      つくば市
    • Year and Date
      2007-07-20
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Annual Research Report 2007 Final Research Report Summary
  • [Presentation] Development of an Ultra-High Resolution Gamma Camera System with CdTe Detectors2007

    • Author(s)
      Naoka Ohmura
    • Organizer
      The 26th Annual Meeting of Japanese Association of Medical Imaging Technology
    • Place of Presentation
      Tsukuba
    • Year and Date
      2007-07-20
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] ピクセル型検出器を用いた超高分解能イメージング2006

    • Author(s)
      尾川 浩一
    • Organizer
      第46回日本核医学会学術総会
    • Place of Presentation
      鹿児島市
    • Year and Date
      2006-11-09
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] ピクセル型検出器とコリメータのアライメントの関係2006

    • Author(s)
      尾川 浩一
    • Organizer
      第46回日本核医学会学術総会
    • Place of Presentation
      鹿児島市
    • Year and Date
      2006-11-09
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] 超高分解能SPECTに関するモンテカルロシミュレーション2006

    • Author(s)
      村石 雅明
    • Organizer
      第92回日本医学物理学会学術大会
    • Place of Presentation
      福岡市
    • Year and Date
      2006-09-29
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Simulation Study on an ultra-high resolution SPECT2006

    • Author(s)
      Masaaki Muraishi
    • Organizer
      The 92nd Scientific Meeting of Japan Society of Medical Physics
    • Place of Presentation
      Fukuoka
    • Year and Date
      2006-09-29
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Ultra-high resolution imaging with a semiconductor detector2006

    • Author(s)
      Koichi Ogawa
    • Organizer
      The 46th Annual Meeting of the Japanese Society of Nuclear Medicine
    • Place of Presentation
      Kagoshima
    • Year and Date
      2006-09-20
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Alignment of a pixilated detector and a collimator2006

    • Author(s)
      Koichi Ogawa
    • Organizer
      The 46th Annual Meeting of the Japanese Society of Nuclear Medicine
    • Place of Presentation
      Kagoshima
    • Year and Date
      2006-09-20
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Relationship between collimator holes and pixels in gamma-ray pixellized semiconductor detector2006

    • Author(s)
      Koichi Ogawa
    • Organizer
      International conference on imaging techniques in subatomic physics, astrophysics, medicine, biology and industry
    • Place of Presentation
      Stockholm,Sweden
    • Year and Date
      2006-06-27
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Relationship between Collimator holes and pixels in gammaray pixellized semiconductor detector2006

    • Author(s)
      Koichi Ogawa
    • Organizer
      International Conference on Imaging Techniques in Subatomic Physics, Astrophysics, Medicine, Biology and Industry
    • Place of Presentation
      Stockholm, Sweden
    • Year and Date
      2006-06-27
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] 半導体検出器を用いたSPECT2006

    • Author(s)
      小宮山 英明
    • Organizer
      第91回日本医学物理学会学術大会
    • Place of Presentation
      横浜市
    • Year and Date
      2006-04-07
    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2007 Final Research Report Summary
  • [Presentation] Single photon emission CT with a semiconductor detector2006

    • Author(s)
      Hideaki Komiyama
    • Organizer
      The 91st Scientific Meeting of Japan Society of Medical Physics
    • Place of Presentation
      Yokohama
    • Year and Date
      2006-04-07
    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2007 Final Research Report Summary

URL: 

Published: 2006-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi