Budget Amount *help |
¥4,420,000 (Direct Cost: ¥3,400,000、Indirect Cost: ¥1,020,000)
Fiscal Year 2010: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2009: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2008: ¥2,860,000 (Direct Cost: ¥2,200,000、Indirect Cost: ¥660,000)
|
Research Abstract |
A concept accelerometer was newly proposed which uses an optical interference of propagated light in Si waveguide. In this sensor, one waveguide of Mach-Zehnder interferometer (MZI) has floating beam structure (air-bridge type) which crosses with a cantilever supporting a proof mass in same plane. When the inertial force is applied to the proof mass, the floating waveguide is expanded and the output of the MZI is modulated. As a result of optical simulation and measurement of fabricated device, optical loss at the intersection of waveguide and supporting cantilever (50μm in width) becomes very small when the f the waveguide at the intersection is Multi-Mode interference (MMI) waveguide. Finally, we confirm the performance of the fabricated accelerometer by measurement of its optical modulation response to applying force.
|