Study on Sensitive and Simple Seismic Diagnosis for Wooden Houses Built before 1981
Project/Area Number |
21560605
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Building structures/materials
|
Research Institution | Toyota National College of Technology |
Principal Investigator |
IMAOKA Katsuya 豊田工業高等専門学校, 建築学科, 教授 (20193667)
|
Project Period (FY) |
2009 – 2011
|
Project Status |
Completed (Fiscal Year 2011)
|
Budget Amount *help |
¥4,810,000 (Direct Cost: ¥3,700,000、Indirect Cost: ¥1,110,000)
Fiscal Year 2011: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2010: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2009: ¥3,250,000 (Direct Cost: ¥2,500,000、Indirect Cost: ¥750,000)
|
Keywords | 耐震診断 / 木造住宅 / 固有振動数 / ねじれ振動 / 水平起振実験 / 人力起振実験 / 共振加振 / 耐震補強 |
Research Abstract |
In order to evaluate the seismic performance of 2-storied wooden houses which were built before 1981, sensitive and simple seismic diagnosis using horizontal vibration generator have been carried out to over 100 houses in Toyota city or Nagoya area. From the investigation, the natural frequency of the house becomes higher when the weight of the roof is lighter and the seismic capacity grade ratio is bigger in case of full 2-storied type. When the house has enough measurement space at the second floor, the torsional amplitude ratio from the vibration test properly corresponds to the eccentricity of the house in case of span direction.
|