• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Functional and morphological integrated assessments of hepato-biliary-pancreatic carcinomas using 320 detector-row CT

Research Project

Project/Area Number 21591563
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionKobe University

Principal Investigator

YOSHIKAWA Takeshi  神戸大学, 大学院・医学研究科, 特命講師 (40332788)

Co-Investigator(Kenkyū-buntansha) OHNO Yoshiharu  神戸大学, 医学研究科, 特命准教授 (30324924)
TAKENAKA Daisuke  神戸大学, 医学研究科, 准教授 (60258233)
MAEDA Tetsuo  神戸大学, 医学研究科, 特命講師 (00457095)
MATSUMOTO Sumiaki  神戸大学, 医学研究科, 特命講師 (60397833)
SUGIMURA Kazuro  神戸大学, 医学研究科, 教授 (00136384)
村瀬 研也  大阪大学, 医学系研究科, 教授 (50157773)
Co-Investigator(Renkei-kenkyūsha) MURASE Kenya  大阪大学, 医学研究科, 教授 (50157773)
Project Period (FY) 2009 – 2011
Project Status Completed (Fiscal Year 2011)
Budget Amount *help
¥5,070,000 (Direct Cost: ¥3,900,000、Indirect Cost: ¥1,170,000)
Fiscal Year 2011: ¥520,000 (Direct Cost: ¥400,000、Indirect Cost: ¥120,000)
Fiscal Year 2010: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2009: ¥3,900,000 (Direct Cost: ¥3,000,000、Indirect Cost: ¥900,000)
Keywords領域検出器型CT / 上腹部 / 臓器血流・機能測定 / 臓器血流測定ソフトウエア / 低X線量CT撮影 / 形態・機能融合診断法
Research Abstract

We evaluated newly-developed Area-Detector CT in functional and morphological assessments of the upper abdominal organ function and diseases. Area-Detector CT was superior to conventional CT in assessment of fine abdominal vessels. We developed CT scanning protocol and injection protocol of contrast medium for abdominal functional(perfusion) CT, correction software for respiratory misregistrations, and software for perfusion analysis with three different analytic methods. Our results showed irradiation during perfusion CT can be reduced to 1/3 and volume and injection rate of contrast medium can be reduced to 1/3 of those in the conventional methods and respiratory misregistrations less than 3 cm can be satisfactorily corrected. Effects of cardiac function were found and it needs to be compensated. In patients with abdominal diseases, we found new findings such as interactions in blood perfusion among the organs and useful perfusion parameters for diagnosis for malignant tumors. It was also found that perfusion CT is useful for assessment of tumor responses after radiotherapy and anticancer agents as well as residual organ function. The results of this study suggest functional and morphological integrated CT using Area-Detector CT can be superior to those of conventional morphological CT in assessments of the upper abdominal organ function and diseases.

Report

(4 results)
  • 2011 Annual Research Report   Final Research Report ( PDF )
  • 2010 Annual Research Report
  • 2009 Annual Research Report
  • Research Products

    (58 results)

All 2012 2011 2010 2009

All Journal Article (14 results) (of which Peer Reviewed: 13 results) Presentation (44 results)

  • [Journal Article] Hepatic CT perfusion measurements : A feasibility study for radiation dose reduction using new image reconstruction method2012

    • Author(s)
      Negi N, Yoshikawa T, Ohno Y, Somiya Y, Sekitani T, Sugihara N, Koyama H, Kanda T, Kanata N, Murakami T, Kawamitsu H, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: (in press) Issue: 11 Pages: 3048-3054

    • DOI

      10.1016/j.ejrad.2012.04.024

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Objective evaluation of the correction by non-rigid registration of abdominal organ motion in low-dose 4D dynamic contrast-enhanced CT2012

    • Author(s)
      Piper J, Ikeda Y, Fujisawa Y, Ohno Y, Yoshikawa T, O' Neil A, Poole I
    • Journal Title

      Phys Med Biol

      Volume: 57(6) Pages: 1701-15

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Perfusion measurement of the whole upper abdomen of patients with and without liver diseases : Initial experience with 320-detector row CT2012

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Fujisawa Y, Kanata N, Yamaguchi M, Seo Y, Yano Y, Koyama H, Kitajima K, Takenaka D, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: (in press) Issue: 10 Pages: 2470-2475

    • DOI

      10.1016/j.ejrad.2011.10.009

    • Related Report
      2011 Annual Research Report 2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] CT hepatic perfusion measurement : Comparison of three analytic methods2012

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Kanata N, Koyama H, Takenaka D, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: (in press) Issue: 9 Pages: 2075-2079

    • DOI

      10.1016/j.ejrad.2011.07.003

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT : Quantitative assessment of emphysematous changes in smokers' lung parenchyma2011

    • Author(s)
      Koyama H, Ohno Y, Yamazaki Y, Matsumoto K, Onishi Y, Takenaka D, Yoshikawa T, Nishio M, Matsumoto S, Murase K, Nishimura Y, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: (in press) Issue: 6 Pages: 1330-4

    • DOI

      10.1016/j.ejrad.2011.03.037

    • Related Report
      2011 Annual Research Report 2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT2011

    • Author(s)
      Kitajima K, Maeda T, Ohno Y, Yoshikawa T, Konishi M, Kanda T, Onishi Y, Matsumoto K, Koyama H, Takenaka D, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: 80(2) Pages: 219-23

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Comparison of Capability of Abdominal 320-Detector Row CT and of 16-Detector Row CT for Small Vasculature Assessment2011

    • Author(s)
      Sugihara R, Kitajima K, Maeda T, Yoshikawa T, Konishi M, Kanata N, Kanda T, Koyama H, Takenaka D, Ohno Y, Sugimura K
    • Journal Title

      Kobe J Med Sci

      Volume: 56(4)

    • NAID

      110009585984

    • Related Report
      2011 Final Research Report 2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] マルチスライスCTによる肝画像診断の進歩:肝灌流検査としての臨床応用2011

    • Author(s)
      吉川武、大野良治、神田知紀、金田直樹、矢野嘉彦、瀬尾靖、福本巧、具英成
    • Journal Title

      肝胆膵画像

      Volume: 13(1) Pages: 45-50

    • Related Report
      2011 Final Research Report 2010 Annual Research Report
  • [Journal Article] Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT2011

    • Author(s)
      Ohno Y, Koyama H, Matsumoto K, Onishi Y, Takenaka D, Fujisawa Y, Yoshikawa T, Konishi M, Maniwa Y, Nishimura Y, Ito T, Sugimura K
    • Journal Title

      Radiology

      Volume: 258(2) Pages: 599-609

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] CT hepatic perfusion measurement : Comparison of three analytic methods2011

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Kanata N, Koyama H, Takenaka D, Sugimura K
    • Journal Title

      Eur J Radiol.

      Volume: (Epub)(掲載確定)

    • Related Report
      2011 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT2011

    • Author(s)
      Kitajima K, Maeda T, Ohno Y, Yoshikawa T, Konishi M, Kanda T, Onishi Y, Matsunioto K, Koyama H, Takenaka D, Sugimura K
    • Journal Title

      Eur J Radiol

      Volume: 80 Pages: 219-23

    • Related Report
      2011 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT2011

    • Author(s)
      Ohno Y, Koyama H, Matsumoto K, Onishi Y, Takenaka D, Fujisawa Y, Yoshikawa T, Konishi M, Maniwa Y, Nishimura Y, Ito T, Sugimura K.
    • Journal Title

      Radiology

      Volume: 258 Pages: 599-609

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Hepatic computed tomography perfusion : comparison of maximum slope and dual-input single-compartment methods2010

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Kanata N, Koyama H, Nogami M, Takenaka D, Sugimura K
    • Journal Title

      Jpn J Radiol

      Volume: 28(10) Pages: 714-9

    • NAID

      50007728261

    • Related Report
      2011 Final Research Report
    • Peer Reviewed
  • [Journal Article] Hepatic computed tomography perfusion : comparison of maximum slope and dual-input single-compartment methods2010

    • Author(s)
      Kanda T, Yoshikawa I, Ohno Y, Kanata N, Koyama H, Nogami M, Takenaka D, Sugimura K
    • Journal Title

      Jpn J Radiol

      Volume: 28 Pages: 714-9

    • NAID

      50007728261

    • Related Report
      2010 Annual Research Report
    • Peer Reviewed
  • [Presentation] Hepatic CT Perfusion Measurements : Effects of Radiation Dose Reduction and New Image Reconstruction Method2012

    • Author(s)
      Negi N, Yoshikawa T, Ohno Y, Somiya Y, Sekitani T, Kanda T, Murakami T, Kawamitsu H, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      ウィーン、オーストリア
    • Year and Date
      2012-03-01
    • Related Report
      2011 Annual Research Report
  • [Presentation] Hepatic CT Perfusion : Assessment of Liver Tumors2012

    • Author(s)
      Yoshikawa T, Kanda T, Ohno Y, Negi N, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      ウィーン、オーストリア
    • Year and Date
      2012-03-01
    • Related Report
      2011 Annual Research Report
  • [Presentation] Upper Abdominal CT Perfusion : Effects of Contrast Medium Iodine Concentration on the Values Estimated by Three Analytic Methods2012

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Negi N, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      ウィーン、オーストリア
    • Year and Date
      2012-03-01
    • Related Report
      2011 Annual Research Report
  • [Presentation] CT perfusionによる肝腫瘍の評価2012

    • Author(s)
      松尾圭朗、神田知紀、吉川武、大野良治、神山久信、金田直樹、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第18回肝血流動態イメージ研究会
    • Place of Presentation
      神戸
    • Year and Date
      2012-01-28
    • Related Report
      2011 Annual Research Report 2011 Final Research Report
  • [Presentation] 上腹部CT Perfusionによる肝機能の評価2012

    • Author(s)
      金田直樹、吉川武、神田知紀、大野良治、藤沢恭子、根宜典行、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第71回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Related Report
      2011 Final Research Report
  • [Presentation] CT perfusionによる肝腫瘍の評価2012

    • Author(s)
      松尾圭朗、神田知紀、吉川武、大野良治、藤澤恭子、金田直樹、村上徹、神山久信、竹中大祐、杉村和朗
    • Organizer
      第71回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Related Report
      2011 Final Research Report
  • [Presentation] 上腹部CT perfusion :造影剤濃度が解析法に及ぼす影響の検討2012

    • Author(s)
      神田知紀、吉川武、大野良治、藤澤恭子、金田直樹、小西稔、神山久信、北島一宏、竹中大祐、杉村和朗
    • Organizer
      第71回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Related Report
      2011 Final Research Report
  • [Presentation] Hepatic CT Perfusion Measurements : Effects of Radiation Dose Reduction and New Image Reconstruction Method2012

    • Author(s)
      Negi N, Yoshikawa T, Ohno Y, Somiya Y, Sekitani T, Kanda T, Murakami T, Kawamitsu H, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] Hepatic CT Perfusion : Assessment of Liver Tumors2012

    • Author(s)
      Yoshikawa T, Kanda T, Ohno Y, Negi N, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] Upper Abdominal CT Perfusion : Effects of Contrast Medium Iodine Concentration on the Values Estimated by Three Analytic Methods2012

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Negi N, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2012
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] CT Perfusion Assessment of Liver Tumors. 97th Annual Meeting of Radiological Society of North America2011

    • Author(s)
      Yoshikawa T, Kanda T, Ohno Y, Fujisawa Y, Kanata N, Koyama H, Takenaka D, Onishi Y, Kitajima K, Sugimura K
    • Organizer
      RSNA 2010(96 Assembly and Annual Meeting of Radiological Society of North America
    • Place of Presentation
      Chicago(USA)
    • Year and Date
      2011-11-29
    • Related Report
      2011 Final Research Report
  • [Presentation] CT Perfusion Assessment of Liver Tumors2011

    • Author(s)
      Yoshikawa T, Kanda T, Ohno Y, Fujisawa Y, Kanata N, KoyaMa H, Takenaka D, Onishi Y, KitajiMa K, Sugimura K
    • Organizer
      97th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      シカゴ、米国
    • Year and Date
      2011-11-29
    • Related Report
      2011 Annual Research Report
  • [Presentation] Whole Upper Abdominal CT Perfusion Measurements : Effects of Contrast Mediun Iodine Concentration on the Values Estimated by Three Analytic Methods2011

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Fujisawa Y, Murakami T, Koyama S, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      97th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      シカゴ、米国
    • Year and Date
      2011-11-29
    • Related Report
      2011 Annual Research Report
  • [Presentation] Whole Upper Abdominal CT Perfusion Measurements : Effects of Contrast Medium Iodine Concentration on the Values Estimated by Three Analytic Methods2011

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Fujisawa Y, Murakami T, Koyama S, Kanata N, Takenaka D, Koyama H, Kitajima K, Sugimura K
    • Organizer
      97th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      Chicago
    • Year and Date
      2011-11-28
    • Related Report
      2011 Final Research Report
  • [Presentation] AIDRが変える低被ばくCT撮影の今後の姿.腹部領域における低被ばく撮影の臨床応用-特に腹部Perfusion CTを中心に-2011

    • Author(s)
      吉川武
    • Organizer
      Vision for Tomorrow 2011
    • Place of Presentation
      大阪
    • Year and Date
      2011-09-14
    • Related Report
      2011 Annual Research Report
  • [Presentation] AIDRが変える低被ばくCT撮影の今後の姿2011

    • Author(s)
      吉川武
    • Organizer
      Vision for Tomorrow 2011
    • Place of Presentation
      大阪
    • Year and Date
      2011-09-10
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列CTを用いた上腹部血流測定:造影条件の血流値に対する影響2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第17回肝血流動態イメージ研究会
    • Place of Presentation
      横浜
    • Year and Date
      2011-01-29
    • Related Report
      2011 Final Research Report 2010 Annual Research Report
  • [Presentation] 320列CTを用いた上腹部CT Perfusion :臓器血流量の肝疾患群・非疾患群および各種治療前後の比較2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第17回肝血流動態イメージ研究会
    • Place of Presentation
      横浜
    • Year and Date
      2011-01-29
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列CTを用いた上腹部CT Perfusion:臓器血流量の肝疾患群・非疾患群および各種治療前後の比較2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第17回肝血流動態イメージ研究会
    • Place of Presentation
      横浜
    • Year and Date
      2011-01-29
    • Related Report
      2010 Annual Research Report
  • [Presentation] 320列CTを用いた上腹部血流測定:造影条件の血流値に対する影響2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第70回日本医学放射線学会学術集会
    • Place of Presentation
      Web開催
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列CTを用いた上腹部CT Perfusion :臓器血流量の肝疾患群・非疾患群および各種治療前後の比較2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第70回日本医学放射線学会学術集会
    • Place of Presentation
      Web開催
    • Related Report
      2011 Final Research Report
  • [Presentation] Perfusion Measurements of the Whole Upper Abdomen in Patients with and without Liver Diseases : Initial Experiences with 320-Detector Row CT2011

    • Author(s)
      Kanda T, Yoshikawa T, Ohno Y, Kanata N, Yamaguchi M, Koyama H, Takenaka D, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2011
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] Optimization of Contrast Medium Administration in Whole Upper Abdominal CT Perfusion Measurements with 320-Detector Row CT2011

    • Author(s)
      Yoshikawa T, Kanda T, Ohno Y, Konishi M, Kanata N, Koyama H, Takenaka D, Kitajima K, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2011
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列CTを用いた上腹部血流測定:造影条件の血流値に対する影響2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第70回日本医学放射線学会学術集会
    • Place of Presentation
      (Web開催)
    • Related Report
      2011 Annual Research Report
  • [Presentation] 20列CTを用いた上腹部CT Perfusion:臓器血流量の肝疾患群・非疾患群および各種治療前後の比較2011

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、山口雅人、金田直樹、神山久信、竹中大祐、北島一宏、杉村和朗
    • Organizer
      第70回日本医学放射線学会学術集会
    • Place of Presentation
      (Web開催)
    • Related Report
      2011 Annual Research Report
  • [Presentation] Whole Upper Abdominal CT Perfusion Measurements : Optimization of Contrast Medium Administration with 320-Detector Row CT2010

    • Author(s)
      Kanata N, Yoshikawa T, Konishi M, Ohno Y, Kanda T, Koyama H, Takenaka D, Onishi Y, Kitajima K, Koto N, Sugimura K
    • Organizer
      96th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      Chicago
    • Year and Date
      2010-11-29
    • Related Report
      2011 Final Research Report
  • [Presentation] C Whole Upper Abdominal CT Perfusion Measurements : Optimization of Contrast Medium Administration with 320-Detector Row CT2010

    • Author(s)
      Kanata N, Yoshikawa T, Konishi M, Ohno Y, Kanda T, Koyama H, Takenaka D, Onishi Y, Kitajima K, Koto N, Sugimura K
    • Organizer
      96th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      シカゴ、米国
    • Year and Date
      2010-11-29
    • Related Report
      2010 Annual Research Report
  • [Presentation] 320列Area-Detector CTの腹部領域への応用.-上腹部Perfusion CTを中心に-2010

    • Author(s)
      吉川武
    • Organizer
      第1回膵Perfusion CT研究会.教育講演
    • Place of Presentation
      新潟
    • Year and Date
      2010-04-21
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列Area-Detector CTの腹部領域への応用.-上腹部Perfusion CTを中心に-2010

    • Author(s)
      吉川武
    • Organizer
      第1回膵Perfusion CT研究会
    • Place of Presentation
      新潟
    • Year and Date
      2010-04-21
    • Related Report
      2010 Annual Research Report
  • [Presentation] 320列CTによる腹部微細血管描出能の検討:64列CTとの比較2010

    • Author(s)
      北島一宏、前田哲雄、吉川武、大野良治、小西稔、神田知紀、神山久信、竹中大祐、藤井正彦、杉村和朗
    • Organizer
      第69回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Year and Date
      2010-04-08
    • Related Report
      2010 Annual Research Report
  • [Presentation] 320列面検出器型CTを用いた上腹部臓器の血流測定2010

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、前田哲雄、北島一宏、神山久信、竹中大祐、杉村和朗
    • Organizer
      第69回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Year and Date
      2010-04-08
    • Related Report
      2010 Annual Research Report
  • [Presentation] Helical Scan Protocol on 64-Detector Row CT vs.Step-and-Shoot Scan Protocol on 320-Detector Row CT : Capability for Small Abdominal Vasculature Assessment in Routine Clinical Practice.2010

    • Author(s)
      Kitajima K, Maeda T, Yoshikawa T, Kanda T, Konishi M, Ohno Y, Sugimura K.
    • Organizer
      Annual Meeting of European Congress of Radiology 2010
    • Place of Presentation
      ウィーン(オーストリア)
    • Year and Date
      2010-03-14
    • Related Report
      2009 Annual Research Report
  • [Presentation] CT perfusion of the liver : Comparison of three analytic methods.2010

    • Author(s)
      Yoshikawa T, Ohno Y, Takenaka D, Koyama H, Nogami M, Maeda T, Sugimura K.
    • Organizer
      Annual Meeting of European Congress of Radiology 2010
    • Place of Presentation
      ウィーン(オーストリア)
    • Year and Date
      2010-03-14
    • Related Report
      2009 Annual Research Report
  • [Presentation] 320列面検出器型CTを用いた上腹部臓器の血流測定2010

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、前田哲雄、北島一宏、神山久信、竹中大祐、杉村和朗
    • Organizer
      第16回肝血流動態イメージ研究会
    • Place of Presentation
      神戸
    • Year and Date
      2010-01-30
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列面検出器型CTを用いた上腹部臓器の血流測定2010

    • Author(s)
      神田知紀、吉川武、大野良治、小西稔、前田哲雄、北島一宏、神山久信、竹中大祐、杉村和朗
    • Organizer
      第16回肝血流動態イメージ研究会
    • Place of Presentation
      神戸ポートピアホテル(兵庫県)
    • Year and Date
      2010-01-29
    • Related Report
      2009 Annual Research Report
  • [Presentation] 320列CTによる腹部微細血管描出能の検討: 64列CTとの比較2010

    • Author(s)
      北島一宏、前田哲雄、吉川武、大野良治、小西稔、神田知紀、神山久信、竹中大祐、藤井正彦、杉村和朗
    • Organizer
      第69回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Related Report
      2011 Final Research Report
  • [Presentation] CT perfusion of the liver : Comparison of three analytic methods2010

    • Author(s)
      Yoshikawa T, Ohno Y, Takenaka D, Koyama H, Nogami M, Maeda T, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2010
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] Helical Scan Protocol on 64-Detector Row CT vs. Step-and-Shoot Scan Protocol on 320-Detector Row CT : Capability for Small Abdominal Vasculature Assessment in Routine Clinical Practice2010

    • Author(s)
      Kitajima K, Maeda T, Yoshikawa T, Kanda T, Konishi M, Ohno Y, Sugimura K
    • Organizer
      Annual Meeting of European Congress of Radiology 2010
    • Place of Presentation
      Vienna, Austria
    • Related Report
      2011 Final Research Report
  • [Presentation] CT Hepatic Perfusion Measurement : What is the Reliable Method for Analysis?2009

    • Author(s)
      Yoshikawa T, Ohno Y, Takenaka D, Koyama H, Nogami M, Maeda T, Sugimura K
    • Organizer
      95th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      Chicago
    • Year and Date
      2009-12-01
    • Related Report
      2011 Final Research Report
  • [Presentation] CT Hepatic Perfusion Measurement : What is the Reliable Method for Analysis?2009

    • Author(s)
      Yoshikawa T, Ohno Y, Takenaka D, Koyama H, Nogami M, Maeda T, Sugimura K.
    • Organizer
      95th Annual Meeting of Radiological Society of North America
    • Place of Presentation
      シカゴ(米国)
    • Year and Date
      2009-11-29
    • Related Report
      2009 Annual Research Report
  • [Presentation] 320列Area-Detector CTの体幹部における初期経験と可能性2009

    • Author(s)
      吉川武
    • Organizer
      第23回腹部放射線研究会.ランチョンセミナー
    • Place of Presentation
      岡山
    • Year and Date
      2009-06-19
    • Related Report
      2011 Final Research Report
  • [Presentation] 320列Area-Detector CTの体幹部における初期経験と可能性2009

    • Author(s)
      吉川武
    • Organizer
      第23回腹部放射線研究会・セミナー
    • Place of Presentation
      岡山コンベンションセンター(岡山県)(招待講演)
    • Year and Date
      2009-06-19
    • Related Report
      2009 Annual Research Report
  • [Presentation] CT Perfusion法を用いた局所肝血流測定-各解析法の比較-2009

    • Author(s)
      吉川武、大野良治、寺田真理、川西徹、前田哲雄、神山久信、野上宗伸、竹中大祐、杉村和朗
    • Organizer
      第68回日本医学放射線学会学術集会
    • Place of Presentation
      パシフィコ横浜(神奈川県)
    • Year and Date
      2009-04-17
    • Related Report
      2009 Annual Research Report
  • [Presentation] CT Perfusion法を用いた局所肝血流測定.各解析法の比較-2009

    • Author(s)
      吉川武、大野良治、寺田真理、川西徹、前田哲雄、神山久信、野上宗伸、竹中大祐、杉村和朗
    • Organizer
      第68回日本医学放射線学会学術集会
    • Place of Presentation
      横浜
    • Related Report
      2011 Final Research Report

URL: 

Published: 2009-04-01   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi