Budget Amount *help |
¥19,370,000 (Direct Cost: ¥14,900,000、Indirect Cost: ¥4,470,000)
Fiscal Year 2012: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
Fiscal Year 2011: ¥3,380,000 (Direct Cost: ¥2,600,000、Indirect Cost: ¥780,000)
Fiscal Year 2010: ¥14,170,000 (Direct Cost: ¥10,900,000、Indirect Cost: ¥3,270,000)
|
Research Abstract |
Combustion/boiling heat transfer interaction is of primary importance in constructing compact steam generator with tubular-frame combustor. In this series of study, combustion characteristics, boiling heat transfer, exhaust gas properties and mutual interaction were experimentally investigated under steady and unsteady conditions, which gave principal design criteria. The optimized compact steam generator at present has been constructed with tubular flame combustor surrounded by spirally-wound bellows-type flexible tube
|