Study on utilization of micro hydropower using high efficiency and non clog pump reverse water turbine
Project/Area Number |
22560171
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Fluid engineering
|
Research Institution | The University of Tokushima |
Principal Investigator |
FUKUTOMI Junichiro 徳島大学, 大学院・ソシオテクノサイエンス研究部, 教授 (30035646)
|
Project Period (FY) |
2010 – 2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥4,420,000 (Direct Cost: ¥3,400,000、Indirect Cost: ¥1,020,000)
Fiscal Year 2012: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2011: ¥1,040,000 (Direct Cost: ¥800,000、Indirect Cost: ¥240,000)
Fiscal Year 2010: ¥1,950,000 (Direct Cost: ¥1,500,000、Indirect Cost: ¥450,000)
|
Keywords | ポンプ逆転水車 / マイクロ水力 / 再生可能エネルギー / 流体機械 / 流体工学 / ターボ機械 |
Research Abstract |
It has been a major challenge that twigs and leaves flowing into the water turbine block the impeller passage, causing non operating condition or output reduction state in the micro hydropower utilization. By using the single-blade sewage pump as reverse water turbine, it was clarified by numerical analysis and experiment theinternal flow and relationship of water turbine characteristics and pump characteristicsin this study. Moreover, it was found to be able to achieve high-efficiency and the reduction of the radial thrust by using the two-blade reverse water turbine.
|