Pelvic bone atrophy after total hip arthroplasty evaluated by computed tomography
Project/Area Number |
22591336
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | The University of Tokushima |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
YUKATA Kiminori 徳島大学, 病院, 助教 (40564430)
KAWASAKI Yoshiteru 徳島大学, 病院, 助教 (00403733)
HAMADA Daisuke 徳島大学, 大学院・ヘルスバイオサイエンス研究部, 助教 (90380097)
|
Project Period (FY) |
2010 – 2012
|
Project Status |
Completed (Fiscal Year 2012)
|
Budget Amount *help |
¥4,810,000 (Direct Cost: ¥3,700,000、Indirect Cost: ¥1,110,000)
Fiscal Year 2012: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2011: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2010: ¥3,510,000 (Direct Cost: ¥2,700,000、Indirect Cost: ¥810,000)
|
Keywords | X線 / CT / 人工股関節 / 骨萎縮 / CT |
Research Abstract |
Pelvic bone adaptation around the acetabular component (cup) after cementless total hip arthroplasty was evaluated using quantitative computed tomography technique. Acetabular cancellous bone around the cup decreased as much as -36% at one year after operation. On the other hand, the decrease was moderate betweenone-year and two-year evaluation. In contrast, there was tiny bone density change in the cortical bone. We observed neither osteolytic lesion nor loosening of the cup at two years after operation. The changes of load transfer pattern may affect the remodeling of pelvic bone around the cup after total hip arthroplasty.
|