• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Patient organ doses from kV-cone beam CT in image-guided radiation therapy and optimization of image dose and quality.

Research Project

Project/Area Number 24591843
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Radiation science
Research InstitutionKumamoto University

Principal Investigator

ARAKI Fujio  熊本大学, 生命科学研究部, 教授 (00295148)

Co-Investigator(Renkei-kenkyūsha) OHYA Natsuo  熊本大学, 大学院生命科学研究部, 教授 (70281095)
Project Period (FY) 2012-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥4,680,000 (Direct Cost: ¥3,600,000、Indirect Cost: ¥1,080,000)
Fiscal Year 2014: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2013: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2012: ¥2,470,000 (Direct Cost: ¥1,900,000、Indirect Cost: ¥570,000)
KeywordsCone beam CT / IGRT / Monte Carlo simulation / CT dosimetry / 被ばく線量 / kV-CBCT / 吸収線量 / モンテカルロ法
Outline of Final Research Achievements

(1) We developed a novel method to directly evaluate the absorbed dose-to-water for kV-CBCT by Farmer ionization chamber measurements with a 60Co absorbed dose-to-water calibration factor. The absorbed doses for two kV-CBCT systems of the Varian On-Board Imager and the Elekta X-ray Volumetric Imager that currently are in widespread clinical use were measured by using the CT cylindrical water phantom. In addition, the dose distributions in the phantom for both kV-CBCT systems were calculated with Monte Carlo (MC) method and were compared with measured values.
(2) The patient dose distributions from kV-CBCT systems were computed from MC simulations by using patient CT image data sets for five treatment sites of head, “head and neck”, chest, abdomen, and pelvis. The organ doses at each site were quantitatively evaluated from dose-volume histograms. This approach made it possible to compare patient organ doses between two different kV-CBCT systems by using the same patient CT images.

Report

(4 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • 2012 Research-status Report
  • Research Products

    (29 results)

All 2014 2013 2012

All Journal Article (10 results) (of which Peer Reviewed: 8 results,  Acknowledgement Compliant: 4 results) Presentation (19 results)

  • [Journal Article] Monte Carlo calculation of patient organ doses from computed tomography2014

    • Author(s)
      Takeshi Ohno, Fujio Araki, Shoya Tsuzuki, Keiichi Kawasaki
    • Journal Title

      Radiological Physics and Technology

      Volume: 7 Issue: 1 Pages: 176-182

    • DOI

      10.1007/s12194-013-0250-1

    • Related Report
      2014 Annual Research Report 2013 Research-status Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams2014

    • Author(s)
      Fujio Araki and Takeshi Ohno
    • Journal Title

      Medical Physics

      Volume: 41 Issue: 12

    • DOI

      10.1118/1.4901639

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy2014

    • Author(s)
      Kazunari Hioki, Fujio Araki, Takeshi Ohno, Yuji Nakaguchi and Yuuki Tomiyama
    • Journal Title

      Physics in Medicine and Biology

      Volume: 59 Issue: 23 Pages: 7297-7313

    • DOI

      10.1088/0031-9155/59/23/7297

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Three-dimensional gamma analysis of dose distributions in individual structures for IMRT dose verification2014

    • Author(s)
      Yuuki Tomiyama, Fujio Araki, Takeshi Ohno, Kazunari Hioki
    • Journal Title

      Radiological Physics and Technology

      Volume: 7 Issue: 2 Pages: 303-309

    • DOI

      10.1007/s12194-014-0266-1

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] 画像誘導放射線治療におけるkV-cone beam CT の被ばく線量の評価2013

    • Author(s)
      河野友宏,荒木不次男,中口裕二,大野 剛
    • Journal Title

      日本放射線技術学会雑誌

      Volume: 69 Pages: 753-760

    • NAID

      10031186397

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] Measurement of absorbed dose-to-water for an HDR <sup>192</sup>Ir source with ionization chambers in a sandwich setup2013

    • Author(s)
      Fujio Araki, Tomohiro Kouno, and Takeshi Ohno
    • Journal Title

      Medical Physics

      Volume: 40 Issue: 9

    • DOI

      10.1118/1.4816673

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] Monte Carlo calculations of the replacement correction factor, Prepl, for cylindrical chamber cavities in clinical photon and electron beams2012

    • Author(s)
      Fujio Araki
    • Journal Title

      Radiological Physics and Technology

      Volume: 5 Issue: 2 Pages: 199-206

    • DOI

      10.1007/s12194-012-0154-5

    • Related Report
      2012 Research-status Report
    • Peer Reviewed
  • [Journal Article] モンテカルロ計算による画像誘導放射線治療用kV-CBCTの線量分布計算2012

    • Author(s)
      日置一成,荒木不次男,中口裕二,他
    • Journal Title

      医学物理

      Volume: 32 Sup.3 Pages: 69-70

    • Related Report
      2012 Research-status Report
  • [Journal Article] 画像誘導放射線治療におけるkV-CBCTの体内線量分布の測定2012

    • Author(s)
      河野友宏,荒木不次男,中口裕二,他
    • Journal Title

      医学物理

      Volume: 32 Sup.3 Pages: 73-74

    • Related Report
      2012 Research-status Report
  • [Journal Article] Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams2012

    • Author(s)
      Fujio Araki
    • Journal Title

      Physics in Medicine and Biology

      Volume: 57 Issue: 22 Pages: 7615-7627

    • DOI

      10.1088/0031-9155/57/22/7615

    • NAID

      120005652285

    • Related Report
      2012 Research-status Report
    • Peer Reviewed
  • [Presentation] Monte Carlo-calculated patient organ doses from different computed tomography units2014

    • Author(s)
      Takeshi Ohno, Fujio Araki, Masahiro Hatemura, Toshiaki Shimonobou, Takashi Sakamoto, Shuichiro Okumura, Daichi Ideguchi, Keiichi Honda, Kenji Kawata, Takeshi Kuroda
    • Organizer
      The 2nd International Conference on Radiological Science and Technology
    • Place of Presentation
      Sapporo convention Center
    • Year and Date
      2014-10-23 – 2014-10-25
    • Related Report
      2014 Annual Research Report
  • [Presentation] Patient organ doses from CT based on absorbed dose measurement in a cylindrical water phantom2014

    • Author(s)
      Takeshi Ohno, Fujio Araki, Masahiro Hatemura, Toshiaki Shimonobou, Takashi Sakamoto, Shuichiro Okumura, Daichi Ideguchi, Keiichi Honda, Kenji Kawata, Takeshi Kuroda
    • Organizer
      14th Asia-Oceania Congress of Medical Physics (AOCMP) & 12th South East Asia Congress of Medical Physics (SEACOMP)
    • Place of Presentation
      Hotel Novotel Saigaon Centre
    • Year and Date
      2014-10-23 – 2014-10-25
    • Related Report
      2014 Annual Research Report
  • [Presentation] Monte Carlo study of an Elekta radiation beam with the Agility 160-leaf multileaf collimator2014

    • Author(s)
      Ryota Onizuka, Fujio Araki, Takeshi Ohno, Yuji Nakaguthi, Yoshinobu Shimohigashi
    • Organizer
      14th Asia-Oceania Congress of Medical Physics (AOCMP) & 12th South East Asia Congress of Medical Physics (SEACOMP)
    • Place of Presentation
      Hotel Novotel Saigaon Centre
    • Year and Date
      2014-10-23 – 2014-10-25
    • Related Report
      2014 Annual Research Report
  • [Presentation] Dose distribution of an 192-Ir brachytherapy source using Monte Carlo code: PHITS2014

    • Author(s)
      Sakito Fukumoto, Fujio Araki, Takeshi Ohno, Shintaro Hashimoto, Kai Yudai
    • Organizer
      2014 7th Korea-Japan Meeting on Medical Physics
    • Place of Presentation
      BEXCO, Busan, Korea
    • Year and Date
      2014-09-25 – 2014-09-27
    • Related Report
      2014 Annual Research Report
  • [Presentation] Evaluating the organ dose from computed tomotherapy using Monte Carlo calculations2014

    • Author(s)
      Takeshi Ohno and Fujio Araki
    • Organizer
      The American Association of Physicists in Medicine 56th Annual Meeting
    • Place of Presentation
      AustinnConvention Center, Texas, USA
    • Year and Date
      2014-07-20 – 2014-07-24
    • Related Report
      2014 Annual Research Report
  • [Presentation] The accuracy of the Acuros XB advanced dose calculation algorithm for IMRT dose distributions in head and neck2014

    • Author(s)
      Fujio Araki, Ryota Onizuka,Takeshi Ohno, Yuuki Tomiyama, Kazunari Hioki
    • Organizer
      The American Association of Physicists in Medicine 56th Annual Meeting
    • Place of Presentation
      Austin Convention Center, Texas, USA
    • Year and Date
      2014-07-20 – 2014-07-24
    • Related Report
      2014 Annual Research Report
  • [Presentation] Dose distribution of 192-Ir brachytherapy sources using PHITS Monte Carlo code2014

    • Author(s)
      Sakito Fukumoto, Fujio Araki, Takeshi Ohno, Shintaro Hashimoto, Yudai Kai, Kazunari Hioki, Yuuki Tomiyama
    • Organizer
      第107回日本医学物理学会学術大会
    • Place of Presentation
      横浜市「パシフィコ会議」
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] Accuracy of dose calculation algorithms for intensity-modulated radiotherapy in head and neck2014

    • Author(s)
      Ryota Onizuka, Fujio Araki, Takeshi Ohno, Yuuki Timiyama, Kazunari Hioki, Yuji Nakaguchi, Yudai Kai
    • Organizer
      第107回日本医学物理学会学術大会
    • Place of Presentation
      横浜市「パシフィコ会議」
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] Evaluation of organ doses from computed tomography using Monte Carlo calculations2014

    • Author(s)
      Takeshi Ohno and Fujio Araki
    • Organizer
      日本放射線技術学会第70回総会学術大会
    • Place of Presentation
      横浜市「パシフィコ会議」
    • Year and Date
      2014-04-10 – 2014-04-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] Measurement of absorbed dose‐to‐water for an HDR Ir‐192 source with a Farmer ionization chamber in a sandwich setup2013

    • Author(s)
      Fujio Araki, T Kouno, T Ohno, S Kawamura and K Kakei
    • Organizer
      The American Association of Physicists in Medicine 55th Annual Meeting
    • Place of Presentation
      Indianapolis, Indiana, USA
    • Related Report
      2013 Research-status Report
  • [Presentation] Monte Carlo‐Calculated patient dose distributions from kV‐cone beam CT for IGRT2013

    • Author(s)
      K Hioki, F Araki, T Ono, Y Nakaguchi and Y Tomiyama
    • Organizer
      The American Association of Physicists in Medicine 55th Annual Meeting
    • Place of Presentation
      Indianapolis, Indiana, USA
    • Related Report
      2013 Research-status Report
  • [Presentation] Monte Carlo‐Calculated patient organ doses from a diagnostic X‐ray CT2013

    • Author(s)
      T Ohno and F Araki
    • Organizer
      The American Association of Physicists in Medicine 55th Annual Meeting
    • Place of Presentation
      Indianapolis, Indiana, USA
    • Related Report
      2013 Research-status Report
  • [Presentation] Monte Carlo-calculated patient organ doses from a diagnostic X-ray CT2013

    • Author(s)
      Takeshi Ohno, Shoya Tsuzuki, Fujio Araki, Keiichi Kawasaki, et al.
    • Organizer
      第105回日本医学物理学会学術大会
    • Place of Presentation
      横浜市「パシフィコ会議センター」
    • Related Report
      2013 Research-status Report
  • [Presentation] Monte Carlo calculation of patient dose distributions from kV-cone beam CT2013

    • Author(s)
      Kazunari Hioki, Fujio Araki, Takeshi Ohno, Yuji Nakaguchi et al.
    • Organizer
      第105回日本医学物理学会学術大会
    • Place of Presentation
      横浜市「パシフィコ会議センター」
    • Related Report
      2013 Research-status Report
  • [Presentation] The beam quality dependence of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams2013

    • Author(s)
      Fujio Araki and Takeshi Ohno
    • Organizer
      第106回日本医学物理学会学術大会
    • Place of Presentation
      大阪市「大阪大学コンベンションセンター」
    • Related Report
      2013 Research-status Report
  • [Presentation] Monte Carlo-calculated organ dose from kV-cone beam CT for image-guided radiation therapy2013

    • Author(s)
      Kazunari Hioki, Fujio Araki, Takeshi Ohno, Yuji Nakaguchi et al.
    • Organizer
      第106回日本医学物理学会学術大会
    • Place of Presentation
      大阪市「大阪大学コンベンションセンター」
    • Related Report
      2013 Research-status Report
  • [Presentation] Beam modeling for Philips X-ray CT using Monte Carlo simulation2013

    • Author(s)
      Takeshi Ohno, Fujio Araki, Kazunari Hioki, Yuuki Tomiyama
    • Organizer
      第106回日本医学物理学会学術大会
    • Place of Presentation
      大阪市「大阪大学コンベンションセンター」
    • Related Report
      2013 Research-status Report
  • [Presentation] モンテカルロ計算による画像誘導放射線治療用kV-CBCTの線量分布計算2012

    • Author(s)
      日置一成,荒木不次男,中口裕二,他
    • Organizer
      日本医学物理学会学術大会
    • Place of Presentation
      筑波市,つくば国際会議場
    • Related Report
      2012 Research-status Report
  • [Presentation] 画像誘導放射線治療におけるkV-CBCTの体内線量分布の測定2012

    • Author(s)
      河野友宏,荒木不次男,中口裕二,他
    • Organizer
      日本医学物理学会学術大会
    • Place of Presentation
      筑波市,つくば国際会議場
    • Related Report
      2012 Research-status Report

URL: 

Published: 2013-05-31   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi