• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Novel quality assurance of 2 dimensional beam components using enhanced planar detector

Research Project

Project/Area Number 24659568
Research Category

Grant-in-Aid for Challenging Exploratory Research

Allocation TypeMulti-year Fund
Research Field Radiation science
Research InstitutionHiroshima University (2014)
Sapporo Medical University (2012-2013)

Principal Investigator

TANAKA KENICHI  広島大学, 工学(系)研究科(研究院), 准教授 (70363075)

Co-Investigator(Kenkyū-buntansha) TAKADA Jun  札幌医科大学, 医療人育成センター, 教授 (00274134)
SAKURAI Yoshinori  京都大学, 原子炉実験所, 准教授 (20273534)
Project Period (FY) 2012-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥3,770,000 (Direct Cost: ¥2,900,000、Indirect Cost: ¥870,000)
Fiscal Year 2014: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2013: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Fiscal Year 2012: ¥1,170,000 (Direct Cost: ¥900,000、Indirect Cost: ¥270,000)
Keywords放射線治療物理学 / 中性子捕捉療法 / 品質保証 / イメージングプレート / 成分弁別 / 二次元線量分布 / 二次元強度分布 / 線量評価 / 弁別
Outline of Final Research Achievements

In neutron capture therapy (NCT), an essential factor is how to control the dimensions of the irradiation field. From the viewpoint of quality assurance and quality control (QA/QC), it is important to measure the two dimensional distribution of the thermal and epithermal neutrons, which are useful in NCT, and fast neutrons and gamma rays, which are not desirable for NCT. This project proposes the utilization of the imaging plate system as a two-dimensional radiation detector, combined with the enhancers to detect the aimed beam component for this purpose. Consequently, the required condition of the methodology was revealed. The research is still ongoing to realize the method in clinical trials, by evaluating the accuracy and improving the procedure.

Report

(4 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • 2012 Research-status Report
  • Research Products

    (18 results)

All 2015 2014 2013 2012

All Journal Article (9 results) (of which Peer Reviewed: 3 results,  Acknowledgement Compliant: 3 results) Presentation (9 results)

  • [Journal Article] Quality assurance of irradiation field for BNCT using twin imaging plate system2015

    • Author(s)
      K. Tanaka, Y. Sakurai, T. Kajimoto, H. Tanaka, T. Takata, J. Takada, M. Suzuki, S. Endo
    • Journal Title

      KURRI Progress Report

      Volume: 2015

    • Related Report
      2014 Annual Research Report
  • [Journal Article] Study on detecting spatial distribution of neutrons and gamma rays using multi imaging plate system2014

    • Author(s)
      K. Tanaka, S. Sakurai, S. Endo, J. Takada
    • Journal Title

      Applied Radiation and Isotopes

      Volume: 88 Pages: 143-146

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Experimental trial of measuring spatial distribution of neutrons and gamma rays in BNCT using multi imaging plate system2014

    • Author(s)
      K. Tanaka, Y. Sakurai, S. Endo, H. Tanaka, J. Takada
    • Journal Title

      Proceedings of 16th International Congress of Neutron Capture Therapy

      Volume: 1 Pages: 109-110

    • Related Report
      2014 Annual Research Report
    • Acknowledgement Compliant
  • [Journal Article] イメージングプレートを用いたビーム成分ごとの二次元強度分布測定法の検討2014

    • Author(s)
      田中憲一、櫻井良憲、遠藤暁、田中浩基、高田純
    • Journal Title

      第11回日本中性子捕捉療法学会学術大会抄録集

      Volume: 1 Pages: 88-88

    • Related Report
      2014 Annual Research Report
    • Acknowledgement Compliant
  • [Journal Article] Study on detecting spatial distribution of neutrons and gamma rays using multi-imaging plate system2014

    • Author(s)
      K. Tanaka, S. Sakurai, S. Endo, J. Takada
    • Journal Title

      Applied Radiation and Isotopes

      Volume: - Pages: 143-146

    • DOI

      10.1016/j.apradiso.2013.12.038

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] A TPD and AR based comparison of accelerator neutron irradiation fields between 7Li and W targets for BNCT2014

    • Author(s)
      K. Tanaka, S. Endo, S. Yonai, M. Baba, M. Hoshi
    • Journal Title

      Applied Radiation and Isotopes

      Volume: - Pages: 229-232

    • DOI

      10.1016/j.apradiso.2013.11.098

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] Monte Carlo investigation on measuring spatial distribution of neutrons and gamma rays using multi imaging plate system2013

    • Author(s)
      K. Tanaka, Y. Sakurai, S. Endo, J. Takada
    • Journal Title

      Abstracts of 7th Young Researchers’ Boron Neutron Capture Therapy Meeting

      Volume: - Pages: 51-51

    • Related Report
      2013 Research-status Report
  • [Journal Article] イメージングプレートを用いた線質ごとの二次元強度分布の評価―高速中性子寄与の増強2013

    • Author(s)
      田中憲一、 櫻井良憲、 遠藤暁、 高田純
    • Journal Title

      第10回日本中性子捕捉療法学会学術大会抄録集

      Volume: - Pages: 42-42

    • Related Report
      2013 Research-status Report
  • [Journal Article] イメージングプレートを用いたNCT 用線質弁別二次元分布測定法の開発2012

    • Author(s)
      田中憲一、櫻井良憲、遠藤暁、高田純
    • Journal Title

      Proceedings of 2012 Fall Meeting of Atomic Energy Society of Japan

      Volume: N/A Pages: 386-386

    • NAID

      130005051673

    • Related Report
      2012 Research-status Report
  • [Presentation] Investigation of irradiation field monitor for BNCT using multi imaging plate system.2015

    • Author(s)
      K. Tanaka, Y. Sakurai, H. Tanaka, T. Kajimoto, T. Takata, J. Takada, S. Endo
    • Organizer
      International Congress of Radiation Research 2015
    • Place of Presentation
      Kyoto, Japan
    • Year and Date
      2015-05-25 – 2015-05-29
    • Related Report
      2014 Annual Research Report
  • [Presentation] イメージングプレートを用いたビーム成分ごとの二次元強度分布測定法の検討2014

    • Author(s)
      田中憲一、櫻井良憲、遠藤暁、田中浩基、高田純
    • Organizer
      第11回日本中性子捕捉療法学会学術大会
    • Place of Presentation
      大阪
    • Year and Date
      2014-07-07 – 2014-07-09
    • Related Report
      2014 Annual Research Report
  • [Presentation] Experimental trial of measuring spatial distribution of neutrons and gamma rays in BNCT using multi imaging plate system2014

    • Author(s)
      K. Tanaka, Y. Sakurai, S. Endo, H. Tanaka, J. Takada
    • Organizer
      16th International Congress of Neutron Capture Therapy
    • Place of Presentation
      Helsinki, Finland
    • Year and Date
      2014-06-22 – 2014-06-26
    • Related Report
      2014 Annual Research Report
  • [Presentation] Monte Carlo investigation on measuring spatial distribution of neutrons and gamma rays using multi imaging plate system2013

    • Author(s)
      K. Tanaka, Y. Sakurai, S. Endo, J. Takada
    • Organizer
      7th Young Researchers’ Boron Neutron Capture Therapy Meeting
    • Place of Presentation
      Granada, Spain
    • Related Report
      2013 Research-status Report
  • [Presentation] イメージングプレートを用いたビーム成分ごとの2次元分布測定法の開発2013

    • Author(s)
      田中憲一、櫻井良憲、遠藤暁、田中浩基、高田純
    • Organizer
      平成25年度京都大学原子炉実験所専門研究会「BNCTの新展開-特殊な療法から一般的な療法への移行を目指して-」
    • Place of Presentation
      大阪
    • Related Report
      2013 Research-status Report
  • [Presentation] イメージングプレートを用いた線質ごとの二次元強度分布の評価―高速中性子寄与の増強2013

    • Author(s)
      田中憲一、 櫻井良憲、 遠藤暁、 高田純
    • Organizer
      第10回日本中性子捕捉療法学会学術大会
    • Place of Presentation
      岡山
    • Related Report
      2013 Research-status Report
  • [Presentation] Study on detecting spatial distribution of neutrons and gamma rays using multi imaging plate system2012

    • Author(s)
      K. Tanaka, Y. Sakurai, S. Endo, J. Takada
    • Organizer
      15th International Congress on Neutron Capture Therapy
    • Place of Presentation
      筑波
    • Related Report
      2012 Research-status Report
  • [Presentation] A TPD and AR based comparison of accelerator neutron irradiation fields between 7Li and W targets for BNCT2012

    • Author(s)
      K. Tanaka, S. Endo, S. Yonai, M. Baba, M. Hoshi
    • Organizer
      15th International Congress on Neutron Capture Therapy
    • Place of Presentation
      筑波
    • Related Report
      2012 Research-status Report
  • [Presentation] イメージングプレートを用いたNCT 用線質弁別二次元分布測定法の開発2012

    • Author(s)
      田中憲一、櫻井良憲、遠藤暁、高田純
    • Organizer
      日本原子力学会2012年秋の年会
    • Place of Presentation
      東広島
    • Related Report
      2012 Research-status Report

URL: 

Published: 2013-05-31   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi