• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Pore design for the microporous covered stents to maintain blood flow in branching arteries after stenting

Research Project

Project/Area Number 25670628
Research Category

Grant-in-Aid for Challenging Exploratory Research

Allocation TypeMulti-year Fund
Research Field Neurosurgery
Research InstitutionNational Cardiovascular Center Research Institute

Principal Investigator

NAKAYAMA Yasuhide  独立行政法人国立循環器病研究センター, 研究所, 室長 (50250262)

Co-Investigator(Kenkyū-buntansha) NAKAYAMA Atsuyoshi  独立行政法人産業技術総合研究所, 研究員 (10357676)
Project Period (FY) 2013-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥3,640,000 (Direct Cost: ¥2,800,000、Indirect Cost: ¥840,000)
Fiscal Year 2014: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
Fiscal Year 2013: ¥1,820,000 (Direct Cost: ¥1,400,000、Indirect Cost: ¥420,000)
Keywordsステント / 脳動脈瘤 / 血管内治療 / 脳動脈瘤治療 / 頭蓋内ステント / 能動脈瘤治療
Outline of Final Research Achievements

The treatment of large wide-necked cerebral aneurysms is extremely difficult. The covered stents were prepared using balloon-expandable stents by dip-coating to completely cover their struts with polyurethane film and microprocessing to form the honeycomb pattern after expansion. In an the large, wide-necked, outer-sidewall aneurysm canine model, almost all parts of the aneurysms had embolized immediately after stenting, and histological examination at 2 months revealed neointimal formation with complete endothelialization at all stented segments and entirely organized aneurysms. In a perforating artery rabbit model, the lumbar arteries remained patent, with minimal change in the vascular flow pattern, even after placement of a second, overlapping stent. Excellent embolization performance of the designed microporous covered stents without disturbing branching flow was confirmed at the aneurysms in this pilot examination.

Report

(3 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • Research Products

    (12 results)

All 2014 2013

All Journal Article (4 results) (of which Peer Reviewed: 4 results) Presentation (8 results)

  • [Journal Article] Treatment of rabbit carotid aneurysms by hybrid stents (microporous thin polyuretahane-covered stents): Preparation of side-barnches2014

    • Author(s)
      Nishi S, Nakayama Y, Ishibashi-Ueda H, Yoshida M, Yonetani H
    • Journal Title

      J Biomat App

      Volume: 28 Issue: 7 Pages: 1097-1104

    • DOI

      10.1177/0885328213498293

    • Related Report
      2014 Annual Research Report 2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] Occlusion of canine aneurysms using microporous self-expanding stent grafts: Long-term follow-up2014

    • Author(s)
      Nishi S, Nakayama Y, Ishibashi-Ueda H, Yoshida M
    • Journal Title

      Clinical Neurology Neurosurgery

      Volume: 122 Pages: 34-41

    • DOI

      10.1016/j.clineuro.2014.04.013

    • Related Report
      2014 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Occlusion of canine aneurysms using microporous self-expanding stent grafts: Long-term follow-up2014

    • Author(s)
      Nishi S, Nakayama Y, Ishibashi-Ueda H, Yoshida M, Yonetani H
    • Journal Title

      Clinical Neurology Neurosurgery

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Journal Article] 脳動脈瘤治療用多孔薄膜カバードステントの開発(薄膜留置による瘤塞栓性能の評価と微細孔形状の最適化)2013

    • Author(s)
      田地川勉, 中川雄太, 紅林芳嘉, 西正吾, 中山泰秀
    • Journal Title

      日本機械学会論文集B編

      Volume: 79 Pages: 992-1004

    • NAID

      130003374834

    • Related Report
      2013 Research-status Report
    • Peer Reviewed
  • [Presentation] Successful preclinical study of microporous covered stents for intracranial aneurysms2014

    • Author(s)
      Nakayama Y, Satow T, Hamano E, Funayama M, Mizuno T, Kawajiri H, Ishii D, Hayashi M, Tajikawa T
    • Organizer
      American Heart Association Scientific Sesson 2014
    • Place of Presentation
      Chicago
    • Year and Date
      2014-11-16 – 2014-11-18
    • Related Report
      2014 Annual Research Report
  • [Presentation] Establishment of experimental animal models suitable for feasibility testing in the develop,ent of covered stent for intracranial aneusysms2014

    • Author(s)
      Satow T, Nakayama Y, Hamano E, Mizuno T, Funayama M, Ishii D, Hayashi M, Moriwaki T, Kawajiro H, Nishi S
    • Organizer
      ASNR 52nd Annual Meeting & The Foundation of the ASNR Symposium 2014
    • Place of Presentation
      Montreal
    • Year and Date
      2014-05-17 – 2014-05-22
    • Related Report
      2014 Annual Research Report
  • [Presentation] Successful one-device-treatment of intracranial giant and/or wide neck aneurysms. 3 Essential in vivo experimental designs for pre-clinical evaluation2014

    • Author(s)
      Nakayama Y, Satow T, Hamano E, Mizuno T, Funayama M, Ishi D, Hayasgu M, Moriwaki T, Kawajiri H
    • Organizer
      International Congress of the European Society for Cardiovascular and Endovascular Surgery
    • Place of Presentation
      Nice
    • Year and Date
      2014-04-24 – 2014-04-27
    • Related Report
      2014 Annual Research Report
  • [Presentation] 脳動脈治療用多孔薄膜カバードステントの開発:瘤の幾何学形状が瘤塞栓性能に及ぼす影響2014

    • Author(s)
      森脇健司, 紅林芳嘉, 花城卓也, 田地川勉, 中山泰秀
    • Organizer
      日本機械学会第26回バイオエンジニアリング講演会
    • Place of Presentation
      仙台
    • Related Report
      2013 Research-status Report
  • [Presentation] 内膜再生を促進する脳動脈瘤塞栓治療用カバードステントの開発:非臨床動物実験系の基準化2014

    • Author(s)
      中山泰秀, 佐藤 徹, 濱野栄佳, 船山麻理菜, 林 正孝, 石井大造, 水野壮司, 川尻英長, 森脇健司, 田中孝晴, 杉浦寿史
    • Organizer
      第13回日本再生医療学会
    • Place of Presentation
      京都国際会館
    • Related Report
      2013 Research-status Report
  • [Presentation] 脳動脈瘤治療用多孔薄膜カバードステントの開発:親血管の湾曲が瘤塞栓性能の及ぼす影響2014

    • Author(s)
      日高涼, 森脇健司, 田地川勉, 山本恭史, 坂東潔, 中山泰秀
    • Organizer
      日本機械学会関西支部
    • Place of Presentation
      大阪
    • Related Report
      2013 Research-status Report
  • [Presentation] In vivo performance of microporous covered stents for treating cerebral aneurysms2013

    • Author(s)
      Y. Nakayama, T. Satow, E. Hamano, T. Mizuno, M. Funayama, K. Ihara
    • Organizer
      European Society for Artificial Organs Conference 2013
    • Place of Presentation
      イギリス、グラスゴー
    • Related Report
      2013 Research-status Report
  • [Presentation] 脳動脈瘤治療用カバードステントの開発 動物実験モデルの作製2013

    • Author(s)
      中山 泰秀, 佐藤 徹, 濱野 栄佳, 船山 麻理菜, 水野 壮司, 川尻 英長, 森脇 健司, 杉浦 寿史, 飯原 弘二
    • Organizer
      日本人工臓器学会
    • Place of Presentation
      パシフィコ横浜
    • Related Report
      2013 Research-status Report

URL: 

Published: 2014-07-25   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi