• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of digital design system for implant superstructure using optical impression and stress analysis

Research Project

Project/Area Number 25861887
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Dental engineering/Regenerative dentistry
Research InstitutionOsaka University

Principal Investigator

SHINJI Ono  大阪大学, 歯学部附属病院, 医員 (50573739)

Project Period (FY) 2013-04-01 – 2015-03-31
Project Status Completed (Fiscal Year 2014)
Budget Amount *help
¥3,900,000 (Direct Cost: ¥3,000,000、Indirect Cost: ¥900,000)
Fiscal Year 2014: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2013: ¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Keywordsインプラント / 光学印象 / 有限要素法 / 応力解析 / CAD/CAM
Outline of Final Research Achievements

The objective of this research is to digitize all manufacturing process of dental implant treatment and reflect the analysis result of this study to the CAD / CAM system.
We transferred a superstructure shape to CAD / CAM system and developed a system of making the superstructure in 2015. And also, stress distribution of short implants was evaluated using finite element analysis.
Furthermore, we analyzed the effects of different inter-implant distances and the difference between bone level and tissue level implants on stress distribution in the peri-implant bone and the implant components in 2016. To compare the results of this research with the clinical performance, establishing a more useful protocol was suggested.

Report

(3 results)
  • 2014 Annual Research Report   Final Research Report ( PDF )
  • 2013 Research-status Report
  • Research Products

    (5 results)

All 2014 2013

All Presentation (5 results)

  • [Presentation] Effects of implant-abutment connection type on inter-implant stress and abutment micromovements: in silico study2014

    • Author(s)
      Matsuoka T, Nakano T, Yamaguchi S, Yamanishi Y, Ono S, Yatani H
    • Organizer
      Indonesia Japan Prosthodontic Society Joint Meeting 2014
    • Place of Presentation
      Bali
    • Year and Date
      2014-10-31
    • Related Report
      2014 Annual Research Report
  • [Presentation] Comparison of short implant with bicortical anchorage and 13 mm length implant with sinus augmentation on bone stress distribution in maxilla.2014

    • Author(s)
      Hiroyoshi Moriwaki, Tamaki Nakano, Satoshi Yamaguchi, Yasufumi Yamanishi, Shinji Ono, Yasuyoshi Kobayashi, Satoshi Imazato, Hirofumi Yatani
    • Organizer
      EAO 23rd Annual Scientific Meeting
    • Place of Presentation
      Roma
    • Year and Date
      2014-09-26
    • Related Report
      2014 Annual Research Report
  • [Presentation] 上顎前歯部においてアバットメント連結様式の違いが隣接するインプラント間の歯槽骨に及ぼす力学的影響2014

    • Author(s)
      松岡隆、中野環、山西康文、小野真司、矢谷博文
    • Organizer
      第44回日本口腔インプラント学会学術大会
    • Place of Presentation
      東京
    • Year and Date
      2014-09-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] 上顎臼歯部複数歯欠損におけるショートインプラントの埋入本数と補綴設計の違いが周囲骨に及ぼす力学的影響2014

    • Author(s)
      森脇大善、中野環、山口哲、小野真司、矢谷博文
    • Organizer
      第44回日本口腔インプラント学会学術大会
    • Place of Presentation
      東京
    • Year and Date
      2014-09-13
    • Related Report
      2014 Annual Research Report
  • [Presentation] 骨量の不足した上顎臼歯部に用いたショートインプラントに関する力学的検討2013

    • Author(s)
      森脇大善、山口哲、中野環、小林靖宜、小野真司ほか
    • Organizer
      平成25年度公益社団法人日本補綴歯科学会学術大会総会
    • Place of Presentation
      福岡県博多市
    • Related Report
      2013 Research-status Report

URL: 

Published: 2014-07-25   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI