Feasibility basic study of three-dimensional printed device for head and neck immobilization in radiotherapy

Research Project

Project/Area Number 26460715
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Medical Physics and Radiological Technology
Research InstitutionTohoku University

Principal Investigator

Takeda Ken  東北大学, 医学系研究科, 教授 (60312568)

Co-Investigator(Kenkyū-buntansha) 角谷 倫之  東北大学, 大学病院, 助教 (20604961)
Co-Investigator(Renkei-kenkyūsha) Sato Kiyokazu  東北大学, 病院・診療技術部, 主任診療放射線技師 (90800144)
dobashi Suguru  東北大学, 大学院医学系研究科, 助教 (70399806)
Research Collaborator Ito Kengo  東北大学, 病院, 助手 (40705076)
Chiba Mizuki  東北大学, 病院, 助手 (40756441)
Project Period (FY) 2014-04-01 – 2017-03-31
Project Status Completed (Fiscal Year 2016)
Budget Amount *help
¥5,070,000 (Direct Cost: ¥3,900,000、Indirect Cost: ¥1,170,000)
Fiscal Year 2016: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2015: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2014: ¥3,510,000 (Direct Cost: ¥2,700,000、Indirect Cost: ¥810,000)
Keywords放射線治療 / 患者補助固定具 / 3Dプリンター / 3Dプリンター
Outline of Final Research Achievements

We investigated the feasibility of a three-dimensional (3D) -printed head-and-neck (HN) immobilization device. We prepared a 3D-printed immobilization device (3DID) consisting of a mask and headrest with acrylonitrile-butadiene-styrene resin developed from the computed tomography data obtained by imaging a HN phantom. For comparison, a conventional immobilization device (CID) comprising a thermoplastic mask and headrest was prepared using the same HN phantom. We measured the setup error. Furthermore, we measured the changes in the dose due to the difference in the immobilization device material from the photon of 4 and 6 MV. The positional accuracy of the two devices was almost similar. When the thickness was the same, the dose difference was almost similar at a 50 mm depth. At a 1 mm depth, the 3DID-plate had a 2.9-4.2% lower dose than the CID-plate. This study suggested that the positional accuracy and dosimetric properties of 3DID were almost similar to those of CID.

Report

(4 results)
  • 2016 Annual Research Report   Final Research Report ( PDF )
  • 2015 Research-status Report
  • 2014 Research-status Report
  • Research Products

    (5 results)

All 2017 2016

All Journal Article (1 results) (of which Peer Reviewed: 1 results,  Open Access: 1 results,  Acknowledgement Compliant: 1 results) Presentation (4 results) (of which Int'l Joint Research: 1 results)

  • [Journal Article] Evaluation of the Positional Accuracy and Dosimetric Properties of a Three-dimensional Printed Device for Head and Neck Immobilization2017

    • Author(s)
      Sato K, Takeda K, Dobashi S, Kadoya N, Ito K, Chiba M, Kishi K, Yanagawa I, Jingu K
    • Journal Title

      Japanese Journal of Radiological Technology

      Volume: 73 Issue: 1 Pages: 57-65

    • DOI

      10.6009/jjrt.2017_JSRT_73.1.57

    • NAID

      130005289778

    • ISSN
      0369-4305, 1881-4883
    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Presentation] Positional accuracy valuation of a three dimensional printed device for head and neck immobilisation2016

    • Author(s)
      Sato K, Takeda K, Dobashi S, Kishi K, Kadoya N, Ito K, Chiba M, Jingu K
    • Organizer
      European Society for Radiotherapy and Oncology, 35
    • Place of Presentation
      Turin, Italy
    • Year and Date
      2016-05-01
    • Related Report
      2015 Research-status Report
  • [Presentation] Evaluation of the Positional Accuracy and Dosimetric Properties of a Three-dimensional Printed Device for Head and Neck Immobilization2016

    • Author(s)
      Sato K, Takeda K, Dobashi S, Kishi K, Kadoya N, Yanagawa I
    • Organizer
      日本放射線技術学会第72回総会学術大会
    • Place of Presentation
      横浜市パシフィコ横浜会議センター
    • Year and Date
      2016-04-15
    • Related Report
      2015 Research-status Report
  • [Presentation] Positional accuracy valuation of a three dimensional printed device for head and neck immobilization.2016

    • Author(s)
      K. Sato, K. Takeda, S. Dobashi, K. Kishi, N. Kadoya, K. Ito, M. Chiba, K. Jingu.
    • Organizer
      European Society for Therapeutic Radiology and Oncology
    • Place of Presentation
      Turin, Italy
    • Related Report
      2016 Annual Research Report
    • Int'l Joint Research
  • [Presentation] Evaluation of the positional accuracy and dosimetric properties of a three-dimensional printed device for head and neck immobilization.2016

    • Author(s)
      K Sato, K Takeda, S Dobashi, K Kishi, N Kadoya, I Yanagawa.
    • Organizer
      第72回日本放射線技術学会総会学術大会
    • Place of Presentation
      パシフィコ横浜(神奈川県・横浜市)
    • Related Report
      2016 Annual Research Report

URL: 

Published: 2014-04-04   Modified: 2018-03-22  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi