Development and application of a six degree-of-freedom knee joint goniometer

Research Project

Project/Area Number 60870051
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Orthopaedic surgery
Research InstitutionTokyo Medical and Dental University

Principal Investigator

ISHIDA Akimasa  Tokyo Medical and Dental Univ., Professor, 医用器材研究所, 教授 (60016540)

Co-Investigator(Kenkyū-buntansha) KUNO Akira  Toyota Central Research & Development Laboratories, Inc., 試作部, 次長
YAMAMOTO Haruyasu  Tokyo Medical and Dental Univ., Associate Professor, 医学部, 助教授 (10092446)
TAKAHASHI Makoto  Tokyo Medical and Dental Univ., Instructor, 医用器材研究所, 助手 (10154858)
Project Period (FY) 1985 – 1986
Project Status Completed (Fiscal Year 1986)
Budget Amount *help
¥3,700,000 (Direct Cost: ¥3,700,000)
Fiscal Year 1986: ¥1,200,000 (Direct Cost: ¥1,200,000)
Fiscal Year 1985: ¥2,500,000 (Direct Cost: ¥2,500,000)
KeywordsGoniometer / Knee joint / 不安定性 / 膝の動揺性
Research Abstract

To quantify manual test of knee joint instability, we developed a six dgree-of-freedom goniometer and applied it to clinical use. first, we gave mathematical definition of internal-external rotation (axial rotation). Suppose that <phi> , <theta> , <psi> denote Eulerian angles respectively. According to our definition, net axial rotation is given by integrating angular velocity
<omega> =-(d <phi> )/(dt)・sin <theta> +(d <psi> )/(dt)
Second, we developed a six degree-of-freedom knee goniometer. We used four sensors which detect abduction-adduction, flexion-extention, internal-external rotation angles and anterior-posterior displacement. Outputs of these sensors correspond to above-mentioned angles and displacement directly and no processing and calculation is necessary.
Using this goniometer, we tried anterior-posterior drawer test, varus-valgus stress test on normal ten knees and three injured knees. Though amount of data are not enough, results of injured knees were specific to injured ligaments. And good agreement was obtained between these results and roentgenographic measurement.
We are now developing unrestrained measurement apparatus of knee joint motion which adopts two inclinometers and one magnetic sensor.

Report

(2 results)
  • 1986 Final Research Report Summary
  • 1985 Annual Research Report
  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 石田明允: 医用電子と生体工学. 24巻特別号. 190-190 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1986 Final Research Report Summary
  • [Publications] Ishida Akimasa: "Development of a six degree-of-freedom knee joint goniometer" Japanese Journal of Medical Electronics and Biological Engineering. 24. 190-190 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1986 Final Research Report Summary

URL: 

Published: 1987-03-31   Modified: 2016-04-21  