• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Fabrication of Semiconductor Sensor for Immunological Measurement

Research Project

Project/Area Number 61550292
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 計測・制御工学
Research InstitutionUniversity of Tokyo

Principal Investigator

IKEDA Kenji  Faculty of Medicine, University of Tokyo, 医学部, 助手 (70010030)

Co-Investigator(Kenkyū-buntansha) WATANABE Akira  Faculty of Medicine, University of Tokyo, 医学部, 助教授 (00009937)
SAITO Masao  Faculty of Medicine, University of Tokyo, 医学部, 教授 (60010708)
Project Period (FY) 1986 – 1987
Project Status Completed (Fiscal Year 1987)
Budget Amount *help
¥1,800,000 (Direct Cost: ¥1,800,000)
Fiscal Year 1987: ¥400,000 (Direct Cost: ¥400,000)
Fiscal Year 1986: ¥1,400,000 (Direct Cost: ¥1,400,000)
KeywordsImmunological Measurement / Semiconductor Sensor / Thin Organic Film / Plasma-polymerization / 固定化タンパク質 / プラズマ重合法 / グロー放電処理 / ラジカル / 免疫 / 抗体 / 固定化 / センサ
Research Abstract

Fabrication process of semiconductor sensors for immunological measurement was investigated. The device fabrication-process utilized in this work consists of two steps; (1) deposition of thin organic film by plasma technique, and (2) protein immobilization. It is desirable that the electrical properties of organic film are stable and that high density of protein molecules can be immobilized in an orientation-controlled manner.
Electrical property of the organic film was studied using metal/insulator/semiconductor structured capacitors. Plasma-polymerized organic film was deposited onto SiO_2/Si structured substrates. After depositing the Al electrodes, capasitance-voltage characteristics were measured. The hysteresis and the shift of flatband voltage were observed. As far as the technological application to semiconductor sensors is concerned, the above two properties are disadvantageous features. Thus, attempts were made to reduce those effects by heat treatment. The effect was significant. The hysteresis width as well as the shift of flatband voltage were reduced. The best result was obtained in the case of the heat treatment at 200 ゜C for 30 min. in N_2 atmosphere.
Immobilization reaction was performed as the following steps; first, amino-groups were introduced to the surface of the plasma-polymerized film by glow-discharge treatment in HH_3, and then, pre-treated antibody molecules (Fab'-SH domain) were covalently immobilized by a bifunctional cross-linking reagent. Using this method, binding sites of the molecule with the supporting material can uniquely be specified. The density of the immobilized antibody molecules was approximately 6 x 10^<11> cm^<-2>, which agreed well with the theoretically estimated one.

Report

(2 results)
  • 1987 Final Research Report Summary
  • 1986 Annual Research Report
  • Research Products

    (14 results)

All Other

All Publications (14 results)

  • [Publications] 神保泰彦: 医用電子と生体工学. 24. 358 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] 神保泰彦: 医用電子と生体工学. 24. 62-63 (1986)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] 神保泰彦: 医用電子と生体工学. 25. 155 (1987)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: Journal of Molecular Electronics.

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: ""Biosensors and Bioelectronic Systems"Protein Immobilization using Plasma-polymerized Thin Organic Film,"

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: "Semiconductor Sensor using Plasma-polymerized Organic Film" Japanese Journal of Medical Electronics and Biological Engineering. 24. 358 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: "Basic Problems on Semiconductor Sensor for Biological Measurement" Japanese Journal of Medical Electronics and Biological Engineering. 24. 62-63 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: "Semiconductor Sensor using Plasma-polymerized Organic Film" Japanese Journal of Medical Electronics and Biological Engineering. 25. 155 (1987)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: "Orientation-controlled Immobilization of Protein Molecules on Thin Organic Film Deposited by Plasma Technique" Journal of Molecular Electronics.

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] Y.Jimbo: Protein Immobilization using Plasma-polymerized Thin Organic Film. in Biosensors and Bioelectronic Systems, D.L.Wise Eds., CRC Press,

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      1987 Final Research Report Summary
  • [Publications] 神保泰彦: 第25回日本ME学会大会論文集.

    • Related Report
      1986 Annual Research Report
  • [Publications] 神保泰彦: 第1回日本ME学会秋季大会論文集.

    • Related Report
      1986 Annual Research Report
  • [Publications] 神保泰彦: 第33回応用物理学関係連合講演会予稿集.

    • Related Report
      1986 Annual Research Report
  • [Publications] 神保泰彦: 第47回応用物理学会学術講演会予稿集.

    • Related Report
      1986 Annual Research Report

URL: 

Published: 1987-03-31   Modified: 2016-04-21  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi