研究課題/領域番号 |
21K12548
|
研究種目 |
基盤研究(C)
|
配分区分 | 基金 |
応募区分 | 一般 |
審査区分 |
小区分90010:デザイン学関連
|
研究機関 | 拓殖大学 |
研究代表者 |
アルバレス ハイメ 拓殖大学, 工学部, 准教授 (00802258)
|
研究分担者 |
森 豊史 地方独立行政法人東京都立産業技術研究センター, 事業化支援本部多摩テクノプラザ総合支援課, 研究員 (10600637)
|
研究期間 (年度) |
2021-04-01 – 2024-03-31
|
研究課題ステータス |
交付 (2021年度)
|
配分額 *注記 |
4,160千円 (直接経費: 3,200千円、間接経費: 960千円)
2023年度: 2,470千円 (直接経費: 1,900千円、間接経費: 570千円)
2022年度: 1,040千円 (直接経費: 800千円、間接経費: 240千円)
2021年度: 650千円 (直接経費: 500千円、間接経費: 150千円)
|
キーワード | Design specifications / Effect of leaves and mud / Design revision / Embodiment design / Device structure / System configuration / Design / Embodiment / Water lever / Monitoring system / Flood |
研究開始時の研究の概要 |
Every year strong typhoons cause fatalities and severe flood damage on underground facilities, also paralyzing upper urban functions. The purpose of this research is to design, build and test a water level monitoring device that is suitable for urban underground facilities and infrastructure.
|
研究実績の概要 |
In the first year of this research project, design specifications were clarified and the ideation stage for embodiment design was completed. For clarifying design specifications of the water level measurement device, the working prototype was extensively revised. It was also disassembled for inspection and we understood how leaves and mud can affect the sensor. After clarifying design specifications, we came up with several ideas for the embodiment design of the measurement device. Many of them were evaluated by building models and prototypes. As a result, we came up with design proposals for the device structure and system configuration. The design of the measurement device's form was also performed considering functional requirements.
|
現在までの達成度 (区分) |
現在までの達成度 (区分)
3: やや遅れている
理由
Before the start of resent research, the design of the measurement device included sensor technology using a floater. However, the company that provides this technology has been working in a new sensor that is more accurate and can measure water level in real time. We are presently evaluating the use of the new technology in the present research. Although the overall structure and design of the measurement device does not require changes, the detailed design of the device requires some adjustments.
|
今後の研究の推進方策 |
Detailed design of the measurement device using new sensing technology will be performed. Based on it, a working-prototype will be built and evaluated through validation tests. After validation, design will be reviewed and improved, and a final prototype of the measurement device will be built and evaluated from functional and non-functional perspectives.
|