研究実績の概要 |
In FY 2021, we have carried out the survey research that has been going on all over the world and proposed two types of resonators which may produce high KQ product in tissue environment. Furthermore, unlikely for a far-field wireless power transfer (WPT) system, designing a metasurface is critical for a near-field WPT system. First, a robust near-field WPT system using open-loop spiral resonators and a metasurface were designed, and then, the effectiveness of the metasurface is investigated in improving the power transfer efficiency (PTE) and misalignment effects. Furthermore, a study of planar and angular misalignments was also executed to prove the WPT system immunity. The proposed WPT system offers a PTE of 30% when the Rx shifts by the lateral length of the Rx that means the Rx does not remain in front of the Tx. Moreover, the efficiency is almost unchanged due to the angular misalignment. We tested this system only in Air.
|